ARMY UFGS-08 13 73-2011 SLIDING METAL DOORS.pdf
《ARMY UFGS-08 13 73-2011 SLIDING METAL DOORS.pdf》由会员分享,可在线阅读,更多相关《ARMY UFGS-08 13 73-2011 SLIDING METAL DOORS.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-08 13 73 (February 2011)-Preparing Activity: USACE SupersedingUFGS-08 13 73 (May 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2011*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 13 73SLIDING METAL DOOR
2、S02/11PART 1 GENERAL1.1 REFERENCES1.2 SYSTEM DESCRIPTION1.2.1 Performance Requirements1.2.1.1 Door Performance1.2.1.2 Biparting Doors1.2.2 Seal Performance1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.5 DELIVERY, STORAGE, AND HANDLING1.6 WARRANTY1.7 MAINTENANCEPART 2 PRODUCTS2.1 DOORS2.2 PERSONNEL DOORS2.3 S
3、LIDING DOORS2.3.1 Steel-Covered Composite2.3.2 Hollow Metal2.3.3 Flush Steel Tubular Frame2.3.4 Tin-Clad2.3.5 Insulated2.4 OPERATION2.4.1 Power Operators2.4.2 Pneumatic Operators2.4.3 Electric Operators2.4.3.1 Motors2.4.3.2 Controls2.4.4 Electrical Work2.4.5 Transformer2.5 HARDWARE2.6 RAILS2.7 SAFET
4、Y DEVICE2.8 ACCESSORIESSECTION 08 13 73 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.8.1 Track Hood2.8.2 Glass Lights2.8.3 Weatherstripping2.8.4 Locking Device2.8.5 Pass Door2.8.6 Top Guide Rollers2.8.7 Bottom Rollers2.8.8 Track Cleaners2.
5、8.9 Toe Guards2.8.10 Warning Device2.8.11 Track Bumpers2.8.12 Drive Clutch2.8.13 Manual Operators2.9 FINISH2.9.1 Steel Surfaces of Exterior Doors2.9.2 Exposed Steel Surfaces of Interior Doors2.10 SPECIAL FINISHES2.11 SHOP PAINTINGPART 3 EXECUTION3.1 INSTALLATION3.2 FIELD FINISHING3.3 TESTING- End of
6、 Section Table of Contents -SECTION 08 13 73 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-08 13 73 (February 2011)-Preparing Activity: USACE SupersedingUFGS-08 13 73 (May 2009)UNIFIED FACILITIES GUIDE SPE
7、CIFICATIONSReferences are in agreement with UMRL dated January 2011*SECTION 08 13 73SLIDING METAL DOORS02/11*NOTE: This guide specification covers the requirements for horizontal sliding steel doors used primarily for fire rated application and electrically operated horizontal and biparting sliding
8、doors.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.C
9、omments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL*NOTE: This guide specification is intended to cover horizontal sliding steel doors used primarily for fire rated applications. Use a center
10、 parting door at locations where an overhead monorail passes through the opening or where there is limited side room due to the lack of unobstructed wall space adjacent to the opening.The following information should be indicated on the project drawings:a. Size of door openings.b. Fire rating classi
11、fication for each door.c. Type of door operation.SECTION 08 13 73 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-d. Type of power operators and service characteristics, and emergency/safety controls.e. Location and type of power operator contr
12、ols.f. Type of closing system required.*1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title
13、.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automat
14、ically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation o
15、nly.ASTM INTERNATIONAL (ASTM)ASTM A 307 (2007b) Standard Specification for Carbon Steel Bolts and Studs, 60 000 PSI Tensile StrengthASTM A 325 (2010) Standard Specification for Structural Bolts, Steel, Heat Treated, 120/105 ksi Minimum Tensile StrengthASTM A 325M (2009) Standard Specification for St
16、ructural Bolts, Steel, Heat Treated, 830 MPa Minimum Tensile Strength (Metric)ASTM A 36/A 36M (2008) Standard Specification for Carbon Structural SteelASTM A 653/A 653M (2009a) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Pr
17、ocessASTM A 924/A 924M (2010) Standard Specification for General Requirements for Steel Sheet, SECTION 08 13 73 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Metallic-Coated by the Hot-Dip ProcessASTM B 136 (1984; R 2008e1) Standard Method fo
18、r Measurement of Stain Resistance of Anodic Coatings on AluminumASTM B 137 (1995; R 2009) Standard Test Method for Measurement of Coating Mass Per Unit Area on Anodically Coated AluminumASTM B 209 (2007) Standard Specification for Aluminum and Aluminum-Alloy Sheet and PlateASTM B 209M (2007) Standar
19、d Specification for Aluminum and Aluminum-Alloy Sheet and Plate (Metric)ASTM E 330 (2002; R 2010) Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure DifferenceASTM F 568M (2007) Standard Specification for Carbon and Alloy Steel Externally Th
20、readed Metric FastenersNATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)NEMA ICS 2 (2000; R 2005; Errata 2008) Standard for Controllers, Contactors, and Overload Relays Rated 600 VNEMA ICS 6 (1993; R 2006) EnclosuresNEMA MG 1 (2009) Motors and GeneratorsNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
21、NFPA 70 (2011) National Electrical CodeNFPA 80 (2010; TIA 10-2) Standard for Fire Doors and Other Opening ProtectivesTHE SOCIETY FOR PROTECTIVE COATINGS (SSPC)SSPC Paint 28 (1991; E 2004) Water-Borne Epoxy Primer for Steel SurfacesSSPC Paint 36 (2006) Two-Component Weatherable Aliphatic Polyurethane
22、 Topcoat, Performance-BasedU.S. DEPARTMENT OF DEFENSE (DOD)MIL-A-8625 (1993; Rev F; Am 1 2003) Anodic Coatings, for Aluminum and Aluminum AlloysUNDERWRITERS LABORATORIES (UL)UL 10A (2009) Standard for Tin-Clad Fire DoorsSECTION 08 13 73 Page 5Provided by IHSNot for ResaleNo reproduction or networkin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS0813732011SLIDINGMETALDOORSPDF