1、= 3515787 0217170 T42 c-bo-O? ARMY TM 5-809-8 AIR FORCE AFM 88-3, Chap. 8 METAL ROOFING AND SIDING DEPARTMENTS OF THE ARMY AND THE AIR FORCE MARCH 1984 0790 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-m 3535789 0237373 989 m TM 5-809-8lAFM 88-3,
2、Chap. 8 I REPRODUCTION AUTHORIZATION/RESTRICTIONS This manual has been prepared by or for the Government and, except to the extent indicated below, is pub- lic property and not subject to copyright. Copyrighted material included in the manual has been used with the knowledge and permission of the pr
3、o- prietors and is acknowledged as such at point of use. Anyone wishing to make further use of any copy- righted material, by itself and apad from this text, should seek necessary permission directly from the proprietors. Reprints or republications of this manual should include a credit substantiall
4、y as follows: “Joint Depart- ments of the Army and Air Force USA, Technical Manual TM 5-809-8/AFM 883, Chapter 8, Metal Roof- ing and Siding. If the reprint or republication includes copyrighted material, the credit should also state: “Anyone wishing to make hirther use of copyrighted material, by i
5、tself and apart from this text, should seek necessary per- mission directly from the proprietors.” o79 1 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3535789 0237L72 815 *TM 5-809-8IAFM 88-3, Chap. 8 TECHNICAL MANUAL NO. 5-809-8 AIR FORCE MANUAL A
6、FM 88-3, CHAPTER 8 DEPARTMENTS OF THE ARMY AND THE AIR FORCE WASHINGTON, DC, 5 March 1984 METAL ROOFING AND SIDING Purpose . Definitions . . . Basis for Design . Design Stresses . Design Loads . Design Requirements Determination of Minimum Required Section Properties for Corrugated Sheets . Determin
7、ation of Actual Section Properties of Available Corrugated Sheets . I . . Load Test Data Overseas Construction Appendix A: Factors for Moment of Inertia of Corrugated Curved Sheets Appendix B: References Paragraph 1 2 3 4 5 6 7 8 9 10 Page 1 1 1 1 1 2 2 3 4 4 1. Purpose This manual prescribes the cr
8、iteria and procedures for the design of metal roofing and siding for build- ings of military construction. 2. Definitions Metal roofing and siding are cold-formed corruga- ted metal sheets designed to support loads perpen- dicular to the plane of the sheets. Normally the sheets are used in all-metal
9、 structures and are in- stalled exposed to the weather. Roofing as defined in the manual will not be construed as roof decking nor sheet metal roofing to be placed on sheathings. The various types of corrugated configurations vary with each manufacturer. a. Regularly curved sheets. Sheets that have
10、conventional, smooth, regular corrugations sym- metrical about the neutral axis regardless of depth or curved shape. Shapes may be parabolic, sinu- soidal or any other arc-tangent type continuous curve. b. Regularly folded sheets. Sheets that have cor- rugations with right-angled or slanted webs fol
11、ded with or without flats symmetrical about the mid- depth axis regardless of depth or shape. Corruga- tions may be rectangular, trapezoidal such as the ribbed type, triangular as the V-beam type, or any other equally folded continuous configuration. c. Irregularly folded sheets. Sheets with right-a
12、ngled or slanted webs folded with different flat widths at the top and bottom or with flats only at the top or bottom. Depths will be uniform on major corrugations with intermediate stiffened cor- rugations permitted. The basic complete pitch of the corrugated system will be repeated regularly. 3. B
13、asis for design Unless otherwise prescribed herein, the design of roofing and siding will be in accordance with the following: a. Steel. The American Iron and Steel Institute (AISI), “Specification for the Design of Cold- Formed Steel Structural Members”. b. Aluminum. The Aluminum Association, “Spec
14、ification For Aluminum Structures,” and “Aluminum Formed-Sheet Building Sheathing De- sign Guide.” 4. Design stresses The minimum yield stresses and design moduli of elasticity to be used as a basis for design will be as follows: Steel: Fy = 33,000 psi E = 29.510 psi Aluminum: Fy = 27,000 psi E = 10
15、.110 psi The above mechanical properties for steel are based on ASTM A 570, Grade 33, and A 611, Grade C; and for aluminum alloy are based on Alclad 3004 H36. 5. Design loads The roofing and siding will be designed to support *This manual supersedes TM 5-809-8/AFM 88-3, Chapter 8, 15 July 1974 0792
16、1 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-35L578 02L7L73 751 Minimum Resisting Moment Required (in. ibs./ft. width) TM 5-809-8JAFM 88-3, Chap. 8 Minimum Moment of Inertia per ft of width = I min. (inch4/ft.) Minimum Section Mod- ulus per ft.
17、of width = S min. (inchs/ft.) dead, live, and wind loads in accordance with TM 5-809-1/AFM 88-3, Chapter 1. Midspan deflec- tions under maximum design load will be limited to the values stated below. Design of roofing will in- clude consideration of the effects of the maximum allowable deflection of
18、 roofing under maximum de- sign loads. The maximum net inward and outward loads used in the design will be indicated on the drawings. 6. Design requirements The design of roofing and siding will conform to the design specifications and guidance referenced in paragraph 3 except as modified herein, a.
19、 Deflection. To insure watertightness and meet other requirements, the maximum deflections of roofing and siding under full dead, live and/or wind loads will not exceed 1/80th of the span (LBO) assuming sheets are unfastened and free to deflect. b. Thickness. The minimum thickness of sheets will be
20、as follows: Roofing Siding Aluminum .O32 inch .O32 inch Steel-plain, 24 gage 24 gage painted protected c. Roof slopes. Metal roofing will not be used on slopes less than 3 inches on 12 inches except as follows: (i) On slopes of 2 to 3 inches on 12 inches if height of all corrugations and/or interloc
21、king seams is 1 inch or more. (2) On slopes of 1 to 2 inches on 12 inches if height of all corrugations and/or interlocking seams is 2 inches or more or proven sealing systems are provided; however, in all uses slopes must be steep enough to insure a slight positive slope at every point on the roof
22、when it is deflected under full dead and live loads. d. Spacing of supports and length of sheets. Sup- ports for corrugated roofing and siding sheets will be laid out to provide equal or approximately equal multi-span conditions insofar as practicable consid- ering maximum length of sheet at 30 feet
23、 for Army facilities, and 25 feet for Air Force facilities. Sheets in excess of 30 feet, although available, re- quire design provisions for thermal expansion and contraction. 7. Determination of minimum required section properties for corrugated sheets The minimum required values of section propert
24、ies per foot width of corrugated sheets for single-span, two span, and three or more span con- ditions as applicable will be indicated on the draw- ings. For the usual roofing and siding applications, the section properties that must be indicated are the minimum effective moment of inertia per foot
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYTM580981984METALROOFINGANDSIDINGSUPERSEDEDBYARMYARMYTM58092 金属 屋顶 外墙 ARMYARMYTM58092 代替 PDF

链接地址:http://www.mydoc123.com/p-449485.html