ARMY MIL-T-63359-1979 TELESCOPE ELBOW M118A2《M118A2型曲折望远镜》.pdf
《ARMY MIL-T-63359-1979 TELESCOPE ELBOW M118A2《M118A2型曲折望远镜》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-T-63359-1979 TELESCOPE ELBOW M118A2《M118A2型曲折望远镜》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-T-63359 12 = 7997906 0348980 7 MIL-T-6 3 3 59 (AR) 17 July 1979 MILITARY SPECIFICATION TELESCOPE, ELBOW, MllA2 This specification is approved for use by the U.S. Army Armament Research and Development Command, and is available for use by all Departments and Agencies of the Department of Defense.
2、 1. SCOPE 1.1 This specification COVKS an instrument designated as Telescope, Elbow: M11882. 2. APPLICABLE Dg)CUMENTS 2.1 The following documents, of the issue in effect on date of invitation for bids or request for proposal, form a part of this specification to the extent specified herein. Optical
3、Components for Fire Control Instruments; General Specification Governing the Manufacture, Assembly, and Inspection of MIL-P-13926 Fire Control Materiel: General Specification Governing the Manufacture and Inspection of MIL-P- 14232 Parts, Equipment and Tools for Army Materiel, Packaging and Packing
4、of MIL-1-45607 Inspection Equipment, Supply and . Maintenance of Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.2.2 MIL-F-13926. a. Qrder sf preceden
5、ce b. Dimensions and tolerances C. Inorganic protective surface finishes d. Electrical. and electronic assemblies e. Part identification and marking f. Wor kmanskip 3.3 Environmental. 3.3.1 Storage temperatures.- The telescope shall show no evidence of physical failure at room temperature (60 to 90F
6、) ater having been thermally stabilized at -70F and +160%+. 3.3.2 Standard ambient temperatures.- subsequent to meeting the requirements of 3.3.11 the telescope shall meet all the requirements of this specification except 3.3.3 at a standard ambient temperature between 60F and 90F. 3.3.3 Operating t
7、emperatures,- The telescope shall show no evidence of physical failure and shall meet the applicable requirements of 3.9 while thermally stabilized at -40F and +150F. 3.3.4 Vibration.- The telescope shall show no evidence of physical failure (loose, missing OK broken parts) after having been vibrate
8、d at a frequency of 38 cycles per second at an amplitude of 1/16 inch (1/8 inch total excursion) for a period of 5 minutes + 15 seconds. Vibration shall not have caused the eyepiece are to disengage from the initially engaged position. Subsequent to vibration, the telescope shall meet the require- m
9、ents of 3.4 to 3.10 inclusive. 3.4 Cleanliness.- The telescope shall meet the cleanliness requirements of Specification MIL-O-P3830. There shall be no more than 2 particles of dirt visible in the center zone (.614 inch diameter) of the reticle, and the area of each particle shall not be in excess of
10、 the area equivalent to a size 10 dig. There shall be no more than 5 particles of dirt visible in the outer zone of the reticle, and the area of each particle shall not be in excess of the area equivalent to a size 20 dig. 3.5 Sealing.- The telescope shall maintain an internal pressure of dry nitrog
11、en at 5 pounds per square inch (psig) for a minimum period of 2 hours without Issc of pressure in excess 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,
12、-,-3.9 following controls shall be within the values specified when the controls are rotated at a standard ambient temperature of 60 to 90F. is exposed to the extreme temperatures of 3.3.3 shall not exceed the values obtained at standard ambient temperature by more than 100 percent. Operability.- Th
13、e torque required to operate the The torque values obtained when the telescope 3.9,1 Cant correction knob.- With the level vial bubble centered and the tapered holes and eyepiece arm vertical, the running torque required to rotate the cant correction knob shall be 7 inch-pounds - + 1.0 inch-pound. 3
14、.9.2 Mirror, plunger, arm and rheostat.- The level vial mirror (pivotal type only), plunger, eyepiece arm and the rheostat knob shall be mechanically operable when exposed to the operating temperatures of 3.3.3. 3.10 Insulation resistance.- Insulation resistance shall not be less than 10 megohms wit
15、h a potential of 100 volts direct current applied. - 4. QUALITY ASSURANCE PROVISPBNS 4.1 Responsibil.ity for inspection.- Unless otherwise speci- fied in the contract or purchase order, the supplier is respon- sible for the performance of all inspection requirements as specified herein. Except as ot
16、herwise specified, the supplier may utilize his own facilities or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the specificatio
17、n where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements . 4.1.1 General provisions.- The component and subassembly inspection requirements of MIL-F-13926 form a part of the Quality Assurance Provisions of this specification. of inspection term
18、s shall be as listed in MIL-STD-109. Definitions 4.2 First Article (Initial Production) Approval.- The requirement for first article approval and the responsibility (Government or Contractor) for first article testing shall be as specified in the contract. The sample for first article approval tests
19、 shall consist of 3 Elbow Telescopes plus three (3) each of all items covered by SOAP. The sample shall be 5 If . . - - . . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Provided by IHSNot for ResaleNo reproduction or networking permitted without l
20、icense from IHS-,-,-Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-4.5.2.2 Contractor design.- The contractor shall design and supply inspection equipm
21、ent compatible with the “Test Methods and Procedures“ specified in 4.6 of this specification and with the component inspection procedures specified in “Examination“ and “Test Facilities“ requirements of MIL-F-23926. Since tolerance of test equipment is normally considered to within 10% of the produc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILT633591979TELESCOPEELBOWM118A2M118A2 曲折 望远镜 PDF

链接地址:http://www.mydoc123.com/p-448921.html