1、1. SCOPE - MIL-T-55335 bb m 77777Ob OLL1Lb9b 5 m -1 /- -6 +-.O3 b, MIL-T-5 35 (EL) 30 August 197L 1.11 L ITARY SPEC II: I CA? TON TEST FACILITIIS .KIT NK-1191( )/AlE-8505 ( )/AR Adapter, FIX-8506 ( )/AR Adapter, MX-8507 ( )/AR Adapter, MX-8508 ( )/AR Adapter, ia-8509 ( )/AR Adapter, U-8510 ( )/AR Ad
2、apter, FIX-8511 ( ) /AR Adapter, m-8527 ( )/AR Resistance: Power Supply Term MX-( ) Power Supply Term Pa-( ) Power Supply Term MX-( ) Headset Term MX-( ) Plicrophone Term MX- ( ) Interchangeability REQT PARA - 3.13.34 3.13.35 3.13.36 3.13.37 3.13.38 3.13.39 3.13.40 3.13.41 3.13.42 3.13.43 3 13.44 3.
3、13.45 3.13 46 3.13.47 3.13.48 3.13.49 3.13.50 3.13.51 3.13.57 3.13.58 3.13.59 3.13.60 3.13.61 3.13.62 3.13.63 3.13.64 3.13.65 3.13.66 3.13.52 3.13.53 3.13.54 3.13.55 3.13.56 3.16 18 INSP PARA - 4.9.34 4.9.35 4.9.36 4.9.37 4.9.38 4.9.39 4.9.40 4.9.41 4.9.42 4.9.43 4.9.44 4.9.45 4.9.46 4.9.47 4.9.48 4
4、.9.49 4.9.50 4.9.51 4.9.57 4.9.58 4.9.59 4.9.60 4.9.61 4.9.62 4.9.63 4.9.64 4.9.65 4.9.66 4.9.52 4.9.53 4.9.54 4.9.55 4.9.56 4.11 1 1 6.5% for the Breakout Boxes and Adapters (combined ) 1 6.52 for the cables 6.5% for the Power Supply Terminations, Headset and Micro- phone (Combined) 6.5% for the In
5、terchangeability 1 Licensed by Information Handling Servicest MIL-T-55335 66 7797706 OL4L7LLi 3 9 MIL-T- 5 5 3 3 5 (EL) 4.5.3 Group C inspection. - This inspection shail be as listed in Table IV, and shall normally be performed on sample units that have been subject to and met Group A and B inspecti
6、on, allowed, Sample unit(s) shall be selected in accordance with 4.5.4. No defects shall be ! INSPECTION SUBGROUP I: Altitude Temperature Vibration Humidity SUBGROUP II: Spray tight protection Shock, bench-handling Shock, drop SUBGROUP III : TABLE IV - GROUP C INSPECTION REQT INSP PARA PARA - - 3.12
7、.3 4.8.3 3.12.1 4.8.1 3.12.6 4.8.6 3.12.2 4.8.2 3.12.4 4.8.4 3.12.7 4.8.7.1 3.12.7 4.8.7.2 Fungus 3.12.5 4.8.5 4.5.4 a. - Units selected for each Group C inspection shall be selected without regard to their quality in accordance with the following: 4.5.4.1 Subgroup I. - For this subgroup, two units
8、from the first 10 production units shall be selected for the first Group C inspection. For subsequent Group C: inspections, one unit from each successive 25 or fractions thereof shall be selected. 4.5.4.2 Subgroup II. - For this subgroup, two units from the first 10 production units shall be selecte
9、d for the first Group C inspection. For subsequent Group C inspections, one unit from each successive 50 or fractions thereof shall be selected. 19 Licensed by Information Handling ServicesMIL-T-55335 (EL) 4.5.4.3 Subgroup III. - For this subgroup, only one (i) unit(s) from the first 10 production u
10、nits shall be selected for the first Group C inspection, For subsequent inspections, one (i) unit(s) shall be selected when one half of the units on order have been accepted by the Governments QA Representative. 4.5.5 Noncompliance. - The contractor shall immediately report in writing each Group C f
11、ailure occurrence, including details of the failure and characteristics affected. The contractor shall immediately investi- gate the cause of failure and further report the results of investigation and details of the proposed corrective action on (i) the process and mater- ials, as applicable, and (
12、ii) all units of product which were manufactured under the same conditions and which the Government considers subject to the same failure, Reports shall be forwarded to the responsible technical activity designated in the contract through the Quality Assurance Repre- sentative. After corrective acti
13、on has been taken, additional sample units shall be subjected to Group C inspection (all inspections, or the inspections which the sample failed, at the option of the Government) and Group A and B inspection may be reinstituted; however, final acceptance and shipment will be withheld until the Group
14、 C re-inspection results have shown that the corrective action was effective. (See 6.4) 4.5.6 Reinspection of conforming Group C sample units. - Unless otherwise specified, sample units which have been subjected to and passed Group C inspection may be delivered on the contract or order, provided all
15、 damage is repaired, cleaned of all foreign matter, and the sample units are resubjected to and pass Group A inspection. 4.6 Bounce preconditioning. - The.Facilities Kit shall be placed in its normal operating position on a L.A.B. ARC-30-200 vibration table or suitable equivalent. and subjected to a
16、 two (2) minutes vibration. be approximately lg at 25 Hz. After bounce preconditioning, the unit shall not be repaired, aligned, cleaned, or otherwise changed prior to subjection to acceptance inspection. The unit shall be secured to the vibration table The vibration force shall 4.7 Standard test co
17、nditions. - spection shall be performed at normal humidity . Unless otherwise specified, all in- room temperature, pressure, and I ! 20 Licensed by Information Handling ServicesMIL-T-55335 bb W 97777Ob Ollr171ib 7 I MIL-T-55335 (EL) 4.8 Service conditions. - The service condition tests shall be cond
18、ucted as specified. When electrical tests ,are required, the equipment shall meet the requirements of 3.13.1 thru 3.13.68, Upon completion of each service condition test, the equipment shall be subjected to and pass a visual and mechanical inspection. No defects will be allowed. 4.8.1 Temperature (S
19、ee 3.121). - i 4.8.1.1 Operating. - The equipment shall be subjected to the tempera- ture limits in accordance with Methods 501 and 502 of MIL-STD-810, Tests shall be conducted at ambient before and after the temperature tests, and at extreme temperatures when the temperature limits have been reache
20、d, requirements of 3.12,l.l shall be met. The 4.8.1.2 Non-operating. - The equipment shall be subjected to the temperature limits in accordance with Methods 501 and 502 of MIL-STD-810, Electrical tests shall be conducted at ambient before and after the tem- perature tests. The requirements of 3.12.1
21、.2 shall be mt. 4.8.2 Humidity. - The equipment shall be subjected to and meet the humidity test of Specification MIL-T-5422 with the transit case open. upper and lower hold down plate assemblies shall be removed from transit case and placed in the chamber. tests shall be performed before and after
22、the humidity test. ments of 3.12.2 shall be met. The Mechanical-Visual inspection and electrical The require- 4.8.3 Altitude. - The equipment shall be subjected to the altitude tests in accordance with Procedure 1, Method 500, of MIL-STD-810. Electrical tests shall be conducted before and after the
23、altitude test at ambient pressure and at 10,000 feet, the unit(s) shall not be required to operate. The interior of The unit(s) shall be subjected to the test 21 Licensed by Information Handling ServicesMIL-T-55335 (EL) 4.8.6 Vibration. - The equipment shall be subjected to the vibration test in acc
24、ordance with Method 514-1.of MIL-STD-180, except the equipment shall not be operated during vibration, conducted before and after the vibration test. in the test fixture on the vibration table, determine resonant modes of the maintenance kit by varying the frequency of applied vibration slowly throu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILT553351971TESTFACILITIESKITMK1191ARUNITSOFMK1191AR 试验 设备 工具箱 单位 PDF

链接地址:http://www.mydoc123.com/p-448774.html