1、MIL-T- 5 1 5 46A (EA) 31 October 1990 SUPERSEDING 13 December 1989 MIL-T-5 1546 (EA) Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, U.S. Army Chemical Ground, MD 210 10-5423 by using
2、 the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. , Research, Development and Engineering Center, ATTN: SMCCR-PET-S, Aberdeen Proving 1 MILITARY SPECIFICATION TRAINER, PLASTIC FLUID CONTAINER ASSEMBLY 7is specificatio
3、n is approved for use by the U.S. Army Chemical Research, Development and Engineering Center, Department of the Army, and is available for use by all Departments and Agencies of the Department of Defense. i. SCOPE 1.1 Scope. This specification covers one type of plastic fluid container assembly trai
4、ner for the M13 Decontaminating Apparatus, Portable. 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications, standards, and handbooks. The following specifications, stan- dards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the
5、 issues of these documents are those listed in the issue of the De- partment of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited in the solicitation (see 6.2). AMSC NIA FSC 6910 DISTRIBUTION STATEh4ENT A. Approved for public release; distribution is unlimited. Pro
6、vided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-T-CL54bA 69 777970b 04b5750 2 W c MIL-T-5 1546A(EA) STANDARDS MILITARY MIL-STD-1168 - Ammunition Lot Numbering. (Unless otherwise indicated, copies of federal and military specifications, standards, a
7、nd handbooks are available from the Standardization Documents Order Desk, Building 4D, 700 Robbins Avenue, Philadelphia, PA 191 11-5094.) 2.1.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to
8、 the extent specified herein. Unless otherwise specified, the issues are those cited in the solicita- tion. U.S. ARMY CHEMICAL RESEARCH, DEVELOPMENT AND ENGINEElUNG CENTER DRAWINGS 5-51-598 - Plastic Fluid Container Assembly, Trainer SPECIAL PACKAGING INSTRUCTiONS (SPI) P5-51-598 - Plastic Fluid Con
9、tainer Assembly, Trainer (Copies are available from Commander, U.S. Army Information Systems Command, ATT”: ASQNC-AM-CT, Rock Island, IL 61229-7210.) 2.3 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes
10、 precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Materials and components. 3.1.1 Materials. All materials cited on Drawing 5-51-598 and on the subsidiary draw- ings shall conform to the speci
11、fications and drawings listed thereon. 3.1.2 Components. All components of the trainer shall conform to the specifications and drawings listed on Drawing 5-51-598 and subsidiary drawings. 3.2 Manufacture and assembly. The trainer shall be manufactured and assembled in accordance with Drawing 5-51-59
12、8. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-L MIL-T-SL54bA 67 = 797970b 04b575L 4 I w MIL-T-5 1546A(EA) 3.3 Performance. 3.3.1 Leakage. The trainer shall not leak when subjected to a minimurn internal pres- sure of 3 pounds per square inch g
13、age (psig), for a minimum of 15 seconds when tested in accordance with 4.4.6.1. 3.3.2 Drop strength. The trainer shall not leak when dropped from a height of 4 feet onto solid concrete so as to strike on a bottom corner. The container shall be filled to 98 percent capacity with water, when tested in
14、 accordance with 4.4.6.2. 3.3.3 Training container (Drawing 5-51-599) lifting handle. The lifting handle shall support a load of at least 150 pounds for a minimum of 5 seconds without distortion of the handle when tested in accordance with 4.4.6.3. 3.4 First article. Unless otherwise specified in th
15、e contract, a first article sample of trainers shall be produced in accordance with this specification, for examination and test (see 4.3 and 6.2), prior to the start of regular production and each time a new or reworked mold is used during regular production. 3.5 Workmanship. The trainer shall be f
16、ree from cracks, dents, sharp edges, and foreign matter such as dirt, grease, and oily or viscous materials. 4. QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection. Unless otherwise specified in the contract or pur- chase order, the contractor is responsible for the performance of all ins
17、pection require- ments (examinations and tests) as specified herein. Except as otherwise specified in the contract or purchase order, the contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Governm
18、ent. The Government reserves the right to perform any of the inspections set forth in this specification where such inspections are deemed necessary to ensure supplies and services conform to prescribed requirements. a 4.1.1 Responsibility for compliance. All items shall meet all requirements of sec
19、tions 3 and 5. The inspection set forth in this specification shall become a part of the contractors overall inspection system or quality program. The absence of any inspection requirements in the specification shall not relieve the contractor of the responsibility of ensuring that all products or s
20、upplies submitted to the Government for acceptance comply with all require- ments of the contract. Sampling inspection, as part of manufacturing operations, is an acceptable practice to ascertain conformance to requirements, however, this does not authorize submission of known defective material, ei
21、ther indicated or actual, nor does it commit the Government to accept defective material. 3 ,/ Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-4.1.2 Contractor assurance of compliance. The contractors quality program or de- tailed inspection system s
22、hall provide assurance of compliance of all characteristics with the applicable drawing, special packaging instruction, and specification requirements using, as a minimum, the conformance criteria specified herein. 4.1.3 Alternative inspection provisions, Alternative inspection procedures, methods,
23、or equipment, such as statistical process control, tool control, and other types of sampling procedures may be used by the contractor when they provide, as a minimum, the levei of quality assurance required by the inspection provisions specified herein. Prior to applying such alternative procedures,
24、 methods, or equipment, the contractor shall describe them in a written proposal submitted to the Government for evaluation and approval. (See 6.4.) When required, the contractor shall demonstrate that the effectiveness of each proposed alterna- tive is equal to or better than the quality assurance
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILT51546A1990TRAINERPLASTICFLUIDCONTAINERASSEMBLY 塑性 液体 容器 装配 教练员 PDF

链接地址:http://www.mydoc123.com/p-448740.html