ARMY MIL-T-50384 (2)-1990 TELESCOPE ELBOW M114A1《M114A1曲折望远镜》.pdf
《ARMY MIL-T-50384 (2)-1990 TELESCOPE ELBOW M114A1《M114A1曲折望远镜》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-T-50384 (2)-1990 TELESCOPE ELBOW M114A1《M114A1曲折望远镜》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-T-50384 (2) 12 W 7777706 0413352 8 W ._ . MIL-T-50384(AR) AMENDMENT 2 25 JAN i99n.- SUPERSEDING AMENDMENT 1 17 August 1984 MILITARY SPECIFICATION TELESCOPE, SLBOW: M114El This Amendment forms a part of Military Specification MIL-T-50384(MU), dated 16 June 1970, and is approved for use by the U.S
2、. Army Armament, Munitions and Chemical Command and is available for use by all Departments and Agencies of the Department of Defense. PAGE 1 Title: Change from “M114E1“ to “M114A1“ and wherever it appears in the specification. * 2.1, Drawings: Change from “Frankford Arsenal“ to “Armament Research,
3、Development arid Engineering Center“ PAGE 2 * 2.2: Delete “of DSAM 4158.8“. * 3.3: Delete and substitute: “3.3 General specifications. The contractor shall be responsible for the compliance with the requirements of specification MIL-F-13926.“ * 3.10: Delete and substitute 3.10 and add 3.10.1 and 3.1
4、0.2: “3.10: Illumination: 3.10.1 Reticle. The reticle markings shall be visible in ambient light conditions ranging from dusk into night. When required, the use of a mask with a 3/4“ aperture, located on the entrance window, will be permitted to meet the requirements; 3.10.2 External tritium contami
5、nation. There shall be no trace of tritium in excess of 1000 disintesrations per minute (dpm)/lOO sq. cm. on the external surface of the telescope. AMSC N/A 1 OF 3 FSC 1240 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. c Provided by IHSNot for ResaleNo reproductio
6、n or networking permitted without license from IHS-,-,-MIL-T-50389 (2) 12 m 9999906 OY13353 T MIL-T-50384(AR) AMENDMENT 2 PAGE 6 * 4.3.2.2, Table II: After CRITICAL: Change to “None“. Add “MAJOR: 100% Inspection“. Delete “MAJOR: AQL 1.0% Defective“ and renumber as follows: Characteristic 1 to 101, 2
7、 to 102, 101 to 103, 102 to 104, 103 to 105, etc. 114: After operability: Add “(600F(16C) to 90OF(32OC) )It. 115: Change 3.10“ to “3.10.1“. Add: “117 External Tritium contamination 3.10.2 4.2.16 MIL-F-13926 4.7“ 118 Fabrication 3.2 119 Packaging Inspection 5.1 PAGE 11 4.6.2.15, lines 8 and 13: Chang
8、e “3.10 to 3.10.1“. * Add new paragraphs 4.2.16 and 4.7: “4.2.16 External tritium contamination. Contamination test shall be performed by wipinq the telescope with filter paper moistened in distilled water. performed with moderate finger pressure. The damp filter paper shall be placed in a container
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILT5038421990TELESCOPEELBOWM114A1M114A1 曲折 望远镜 PDF

链接地址:http://www.mydoc123.com/p-448707.html