1、MIL-T-46324D 22 M 7779706 Of,LOO b m 17 February 1971 SUPERSEDING MIL-T-46324C(MlJ) 14 August 1968 MILITARY SPECIFICATION TELESCOPES, ELBOW: Ml09 AND 10548042-2 1, SCOPE 1.1 This specification covers two types of non-maintainable four power fixed focus elbow telescopes. 2. APPLICABLE DOCUMENTS 2.1 T
2、he following documents, of the issue in effect on date of invitation for bids or request for proposal, form a part of this specifi- cation to the extent specified herein. SPEC IFICATIONS Military MIL-0-13830 MIL-F-13926 MIL-P-14232 MIL-1-45607 STANDARDS Military MIL-STD- 105 MIL-STD- 109 DRAWINGS Op
3、tical Components for Fire Control Instruments; General Specification Governing the Manufacture, Assembly, and Inspection of Fire Control Materiel, General Speci- fication Governing the Manufacture and Inspection of Parts, Equipment and Tools for Army Materiel, Packaging and Packing of Inspection Equ
4、ipment, Acquisition, Maintenance and Disposition of U.S. Army, Frankford Arsenal Sampling Procedures and Tables for Quality Assurance Terms and Definitions Inspection by Attributes F8565556 F8588780 F10548042-2 Pressure Tester, Two-Station Telescope, Elbow., M109 Telescope, Elbow Assembly FSC 1240 A
5、 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PACKAGING DATA SHEETS 8588780 10548042-2 Packaging of Telescope, Elbow, M109 Packaging of Telescope Elbow 10548042-2 (Copies of specifications, standards, drawings and packaging data sheets required by
6、 suppliers in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer.) 3. REQUIREMENTS 3.1 Fabrication.- The telescopes shall be manufactured in accordnce with the applicable drawing listed in 2.1. 3.2 General specifica
7、tion.- The contractor shall be respnsible for compliance with the following requirements of MIL-F-13926. a. Order of precedence b. Dimensions and tolerances C. inorganic protective surface finishes d. Part identification and marking 3.3 Temperature conditions,- The requirements of this specification
8、 shall be met with the telescope thermally stabilized at an ambient tempera- ture of between 60 and 90“ Fahrenheit (F) unless otherwise specified in the requirement paragraphs. 3.4 Workmanship.- The workmanship requirements of MIL-F-13926 shall be met. The exterior protective surface finishes shall
9、be free of any defects which effect their protective qualities or appearances. Optical surfaces shall be clean and free of any scratches or blemishes which may effect their optical qualities and shall meet the requirements of 3.5.4. 3.5 Environmenta1.- Any telescope subjected to any or all of the re
10、quirements of 3.5.1 to 3.5.3.1 inclusive shall subsequently meet the requirements of 3.5.4 to 3.6.7 inclusive, unless otherwise specified. 3.5.1 Storage temperature,- The telescope shall show no evidence of physical failure such as cement separation, glass breakage or casting failure after having be
11、en exposed and thermally stabilized at ambient temperatures of -80“ and +160F (see 3.5.3.1). 3.5.2 Vibration.- The telescope shall be positioned with the line of sight through the eyepiece and objective tube in a horizontal plane and the telescope supported at the 0.8435 inch diameter of the objecti
12、ve tube, cycles per second with an amplitude of 1/16 inch (1/8 inch total excur- sion) for a period of 5 minutes f 15 seconds. The telescope shall be vibrated at a constant frequency of 30 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-46324
13、D (MU) 3.5.3 Sealing.- The telescope shall show no evidence of leakage in excess of 0.2 psig when subjected to an internal pressure of 5 & 0.10 psig for a period of 2 hours using dry nitrogen having a dew point at least as low as -25F. 3,5.3.1 Condensation (low temperature).- When viewed through the
14、 eyepiece and objective ends of the telescope, there shall be no evidence of condensation at room temperature (60“ to 90F) immediately upon thermal stabilization, subsequent to being subjected to the -80F and prior to the +160F requirement of 3.5.1. 3.5.4 Cleanliness.- The telescope shall meet the c
15、leanliness require- ments of MIL-0-13830. exceed the following limitations of dirt, quantity, and size (see 6.3 size equivalent). When viewed through the eyepiece, dirt shall not a. Inner zone (100 mils diameter).- The maximum size of any one particle of dirt or foreign material shall not exceed the
16、 area equivalent to a size 5 dig. Three particles may be as large as a size 5 dig. Three particles shall not ex- ceed a size 1 dig. Any particles smaller than a size 114 dig shall not be counted. There shall be no more than 6 particles of dirt. b. Outer zone (limited to clear aperture of reticle)- T
17、he maxi- mum size of any one particle of dirt or foreign material shall not exceed the area equivalent to a size 10 dig. Three particles may be as large as a size 10 dig. Smaller sizes may be more in number, but their combined area shall not exceed that of 3 size 10 digs, which is maximum dirt per-
18、mitted. Any particles smaller than a size 114 dig shall not be counted. c. Dirt separation.- The separation between each dirt particle a or foreign matter shall be at least 10 mils for both zones. d. Glass surfaces.- All glass surfaces shall be free of conden- sation, or stains resulting from conden
19、sation, when viewed through the objective and eyepiece ends of the telescope, 3.6 Accuracy. 3.6.1 Collimation.- The optical axis of the telescope shall be in coincidence with the geometric axis within 0.50 mil when the telescope is rotated 3200 mils (90“ to the left and 90“ to the right from a verti
20、cal position of the eyepiece) about the geometric axis as defined by the exterior mounting surface of the Objective tube of the telescope. 3.6.2 Parallax.- Parallax at the optical axis shall not exceed 0.1 mil when viewing a target between 40 meters and infinity. 3 Provided by IHSNot for ResaleNo re
21、production or networking permitted without license from IHS-,-,-MIL-T-4b324D 32 397990b 0333083 3 I 3.6.3 Resolution.- The resolution on the optical axis shall be 15 seconds of arc or less. 3.6.4 Parallelism of reticle and image.- The vertical reticle line shall be parallel to the image of a plumb l
22、ine within 30 minutes of arc, when each of the 3 indices (90 apart) are in position for coincidence with a vertical plane index through the geometric axis of the telescopes objective tube. 3.6.5 Reticle accuracy.- The angular separation for the O to 85 mil span in each of the 4 quadrants of the reti
23、cle shall each be 85 mils f 2.5 mils. 3.6.6 Eyepiece focus.- The eyepiece focus of the reticle shall be set between minus 0.75 and minus 1.0 diopter. 3.6.7 Illumination.- The telescope M109 only shall meet the lfXluminated Reticles“ requirement of MIL-0-13830. Instrument Light M53E1 or equivalent, t
24、he reticle markings shall appear clearly defined when observed in a darkened area. With the reticle illuminated by 4 QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection.- Unless otherwise specified in the contract or purchase order, the supplier is responsible for the per- formance of all
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILT46324D1971TELESCOPESELBOWM109AND10548042M109 10548042 曲折 望远镜 PDF

链接地址:http://www.mydoc123.com/p-448602.html