1、MIL-T-46316B(MU)10 July 1968SUPERSEDINGMIL-T-46316A(MU)17 July 1964MILITARY SPECIFICATIONTELESCOPES, ELBOW: M118 SERIES AND T176E41. SCOPE1.1 This specification covers three similar types of instrumentsdesignated as Telescopes, Elbow: M118, M118C and T176E4. These telescopesare basically identical e
2、xcept for difference in reticle patterns.2. APPLICABLE DOCUMENTS2.1 The following documents, of the issue in effect on date ofinvitation for bids or request for proposal, form a part of this specifi-cation to the extent specified herein.SPECIFICATIONSMilitaryMIL-O-13830MIL-F-13926MIL-P-14232MIL-I-45
3、607optical Components for Fire ControlInstruments; General SpecificationGoverning the Manufacture, Assembly,and Inspection ofFire Control Materiel: General Speci-fication Governing the Manufactureand Inspection ofParts, Equipment and Tools for ArmyMateriel, packaging and packing fInspection Equipmen
4、t, Supply andMaintenance ofSTANDARDSMilitaryMIL-STD-105MIL-STD-109MIL-STD-202DRAWINGSUS Army, Frankford ArsenalF10512985Sampling Procedures and Tables forInspection by AttributesQuality Assurance Terms and DefinitionsTest Methods for Electronic andElectrical Component PartsTelescopes, Elbow: M118, M
5、118C andT176E4FSC 1240Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-46316B(MU)PACKAGING DATA SHEET10512082 Packaging og Telescope, Elbow: T176E410512988 Packaging of Telescope, Elbow: M11810512985 Packaging of Telescope, Elbow: M118c(Copies o
6、f specifications, standards, drawings, and publications requiredby suppliers in connection with specified procurement functions should beobtained from the procuring activity or as directed by the contractingofficer.)3. REQUIREMENTS3.1 Fabrication.- The telescope shall be manufactured in accordancewi
7、th all drawings applicable to the telescope specified in the contract ororder and drawings pertaining thereto.3.2 General specifications.- The contractor shall be responsible foradherence to, and compliance with, the following requirements of Specifica-tions MIL-O-13830 and MIL-F-13926.3.2.1 MIL-O-1
8、3830.(a) Illuminated reticle3.2.2 MIL-F-13926.(a) Order of precedence3.3(b) Dimensions and tolerances(c) Inorganic protective surface finishes(d) Electrical and electronic assemblies(e) Part identification and marking(f) WorkmanshipEnvironmental.3.3.1 Storage temperature.- The telescope shall show n
9、o evidence ofphysical failure and shall meet all performance requirements of this speci-fication at a standard ambient temperature of 60 to 90 Fahrenheit (F)after having been exposed to, and thermally stabilized at, ambient tempera-tures of -80 and +160F.3.3.2 Operating temperatures.- The telescope
10、shall meet the applic-able requirements of 3.9 while exposed to and thermally stabilized atambient temperatures of -40 and +150F.3.3.3 Vibration.- The telescope shall be vibrated at a frequency of30 cycles per second with an amplitude of 1/16 inch (1/8 inch total ex-cursion) for a period of 5 minute
11、s 15 seconds. Subsequent to vibrationthere shall be no evidence of physical failure and the telescope shall meetthe requirements of 3.4 to 3.10 inclusive.2.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-46316B(MU)3.4 Cleanliness.- The telescop
12、e shall meet the cleanliness require-ments of Specification MIL-O-13830. There shall be no more than 2 particlesof dirt visible in the center zone,(.614 inch diameter) of the reticle,and the area of each particle shall not be in excess of the area equivalentto a size 10 dig. There shall be no more t
13、han 5 particles of dirt visiblein the outer zone of the reticle, and the area of each particle shall notbe in excess of the area equivalent to a size 20 dig.3.5 Sealing.- The telescope shall show no evidence of leakage whensubjected to an internal pressure of dry nitrogen at 5 pounds per squareinch
14、gage (psig) for a minimum period of 5 minutes. The interior atmos-phere of the accepted telescope shall contain nitrogen having a dew pointat least as low as -25F. The internal pressure of the accepted telescopeshall be between 0.1 to 0.25 psig.3.6 Orientation.- The telescope shall meet the requirem
15、ents of 3.7with the kingpin holes vertical, the level vial bubble centered, themechanical cant index line indicating zero, and the eyepiece arm horizontal.3.7 Accuracy.3.7.1 Collimation.- The line of sight through the boresight point ofthe reticle shall be 20 mils 1.0 mil above the geometric axis an
16、d within1.0 mil of a plumb line passing through the geometric axis.3.7.2 Repeatability.- The line of sight through the boresight pointof the alternate reticle shall coincide with an established line of sightthrough the boresight point of the primary reticle within 0.1 mil.3.7.3 Parallelism of reticl
17、e and image.- The horizontal reticle linenearest the geometric axis of each reticle shall be parallel to a horizontaltarget line within thirty minutes of arc.3.7.4 Reticle accuracy,- The angular value between the zero rangemark and the maximum range mark (in the finished telescope) shall be asindica
18、ted on the reticle-drawing within 0.25 mil.3.7.5 Boresight error due to reticle rotation.- With the verticalline of the reticle in coincidence with a plumb line, the line of sightestablished at the boresight point shall not deviate more than 0.25 milwhen the reticle line is canted 5 degrees to the l
19、eft and 5 degrees to theright of the plumb lien by means of the cant correction knob.3.7.6 Eyepiece focus.- The eyepiece focus shall be fixed between thelimits of -0.75 and -1.0 diopter.3.7.7 Resolution.- The resolution at the optical axis shall be 12seconds of arc or less.3.7.8 Parallax.- Parallax
20、at the geometric axis shall not exceed0.15 mil when viewing a target at 600 meters 25 meters.3.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-46316B(MU)3.8 Illumination.3.8.1 Level vial.- The lamp for level vial illumination, whenenergized wit
21、h 18 VDC and then 28 VDC, shall provide sufficient illumina-tion at each voltage for the level vial markings to be clearly definedwhen observed in a darkened area.3.8.2 Reticle.- The lamp for reticle illumination, when energizedwith 18 VDC and then 28 VDC, shall provide sufficient illumination ateac
22、h voltage for the reticle markings to be clearly defined when observedin a darkened area. Rotation of the rheostat knob shall cause a changein illumination of the reticle only.3.9 Operability. - The torque required to operate the followingcontrols shall be within the values specified when the contro
23、ls are ro-tated at a standard ambient temperature of 60 to 90F. The torquevalues obtained when the telescope is exposed to the extreme temperaturesof 3.3.2 shall not exceed the values obtained at standard ambient tem-perature by more than 100 percent.3.9.1 Cant correction knob.- With the level vial
24、bubble centeredand the kingpin holes and eyepiece arm vertical, the running torquerequired to rotate the cant correction knob shall be 7 inch-pounds 1.0inch-pound.3.9.2 Reticle shift lever.- The running torque required to rotatethe reticle shift lever shall be 3 inch-pounds 1.0 inch-pound.3.9.3 Mirr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILT46316B1968TELESCOPEELBOWM118SERIESANDT176E4PDF

链接地址:http://www.mydoc123.com/p-448600.html