ARMY MIL-STD-1466-1983 SAFETY CRITERIA AND QUALIFICATION REQUIREMENTS FOR PYROTECHNIC INITIATED EXPLOSIVE (PIE) AMMUNITION《火引爆(PIE)炸弹的安全标准和限制要求》.pdf
《ARMY MIL-STD-1466-1983 SAFETY CRITERIA AND QUALIFICATION REQUIREMENTS FOR PYROTECHNIC INITIATED EXPLOSIVE (PIE) AMMUNITION《火引爆(PIE)炸弹的安全标准和限制要求》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-STD-1466-1983 SAFETY CRITERIA AND QUALIFICATION REQUIREMENTS FOR PYROTECHNIC INITIATED EXPLOSIVE (PIE) AMMUNITION《火引爆(PIE)炸弹的安全标准和限制要求》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、- MIL-STD-1466 25 March 1983 M I L I TA, STAN DAR LI SAFETY CRITEPIA AND QUALIFICATION REQUIREt1ENTS FOR PYRCTECHF!IC INITIATED EXPLOSIVE (PIE) AMMUFIITION NO DELIVERABLE DATA REQUIRED BY THIS CIflCUMEF!T FSC 13GP THIS DOCUMENT ONTAINS /o PAGES. -. ._ _ Provided by IHSNot for ResaleNo reproduction o
2、r networking permitted without license from IHS-,-,-MIL- STD- 3.466 25 March 1983 DEPARTMENT OF DEFENSE Washington, DC 20301 Safety Criteria and Qualification Requirements for Pyrotechnic Initiated Explosive (PIE) Ammunition MIL-STD-1456 1. This hlilitary Standard is approved for use by all Departme
3、nts and Agencies of the Department of Defense. 2. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, U.S. Army Armament Research and Development Command, Attn: DRDAR-TST-S, Dover, NJ. 07
4、801 by using the self-addressed Standardization Document Improvement Proposal (ED Form 1426) appearing at the end of this document or by letter. Comments shall be forwarded through the designated Reviewing Activity listed for each Service in 6.1. Provided by IHSNot for ResaleNo reproduction or netwo
5、rking permitted without license from IHS-,-,-MI L-STD-I 466 25 March 1983 1. SCOPE. 1.1 Purpose: This standard establishes the design safety criteria and qualification requirements for the generic family of pyrotechnic i ni ti a ted ex pl o si ve ( PI E) ammunition. 1.2 Application: This document ap
6、plies specifically to PIE config- urations 40mm and below. While the ammunition is qualified as a cartridge, the primary emphasis of this document pertains to the specific interactions of the pyrotechnic initiation train in the projectile and the environmental conditions required for initiation. 2.
7、- REFERENCE DOCUMENTS. 2.1 Issues of documents. The following documents of the issue in effect on the date of the invitation of bids or request for proposal form a part of this standard to the extent specified herein. STAN DARDS M 1 LI TARY NIL-STD-331 and Performance Tests for MI L-STD-444 - Nomenc
8、lature and definitions in the Ammunition Area . MIL-STD-650 - Explosive, Sampling, Inspection Testing MIL-STD-810 - Environmental Test Methods MI L-STD-882 - System Safety Program Requirements MIL-STD-1316 - Fuze Design, Safety Criteria for DOD-STD-2105 - Hazard Assessment Tests for Navy Non-Nuclear
9、 - Fuze and Fuze Components , Environmental Ordnance 2.2 Other publications. The following documents form a part of this standard to the extent specified herein. issue in effect on the date of the invitation for bids or request for proposal shall apply. Unless otherwise indicated, the DLAR 8220.1 AF
10、SC DH 1-6 NAVORD OD 44942 ADA- 0862 5 9 Department of Defense Explosive Hazard C1 assi fi cation Procedures Design Handbook, System Safety Weapon System Safety Guide1 ines Handbook Joint Services Safety and Performance Manual for Qualification of Explosives for Plil itary Use (Copies of specificatio
11、ns, standards, drawings, and pub1 ications required by contractors in connection with, specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer.) 1 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from
12、 IHS-,-,-b?IL-STD-1466 25 March 1983 3. DEFINITIONS. 3.1 The definitions of MIL-STD-444 generally apply to ammunition terms used in this standard and the definitions of ADA086259 apply to the explosive terms. specific definitions apply: ammunition is any ammunition in which the main charge is initia
13、ted by the effects of combustion of incendiary mixes that are initiated upon target impact. For interpretation of this standard, the following 3.1.1 Pyrotechnic Initiated Explosive (PIE) Ammunition - PIE 3.1.2 Incendiary Mixes - Pyrotechnic formulations which upon initiation rapidly convert to high
14、temperature gases and hot particles. 3.1.3 Eooster Explosives - are compounds of formulations such as Tetryl or CH-6 which are used to transmit and augment the detonation reaction with sufficient energy to initiate a stable detonation in the !lain CharcJe explosive. 3.1.4 Hain Charge Explosives - ar
15、e compounds or formulations such as TF!T, Composition B, or ti-6 which are used as the final charge in any explosive application. These explosives, because of their insensitivity, ordinarily require initiation by a booster explosive. 4, GENERAL REQUIRENENTS. 4.1 Cartridge cases, primers arid propell
16、ants must be safe throughout the intended logistic cycle and be compatible with their prespective gun systems. The data required for evaluation of such shall be addressed in the System Safety Program (see 5.2.2). 4.2 Incendiary mixes used in the assembly of the PIE projectiles shall be qualified in
17、accordance with the test procedures specified herein. 4.3 The explosive compositions used in the assembly of the PIE projectiles shall be either: a. b. A qualified in-line explosive as defined in Materials meetina the requirements of ADA-O86259 as a booster or main charge explosive. MI L-STD-1316. 2
18、 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-Lqbh 13 777771L 0075787 3 M MIL-STD-1466 25 March 1983 NOTE: proposed projectile application has been approved by the developing service(s) cognizant safety authority. A booster explosive may b
19、e used as a main charge explosive if the 5. SPECIFIC REQUIREMENTS. 5.1 Safety qualification Tests. The safety tests enumerated below Accordingly, the test matrix includes safety A specific test program should are designed to qualify small caliber PIE ammunition (4mm and below) throughout the life cy
20、cle. qual ification/verification tests y logistic hand1 ing and storage tests y as well as ammunition development tests. not be limited to or include all tests described .in this document. The selection of the tests and test parameters shall be based on PIE initiation mechanism and the measured or a
21、nalytically forecast logistic cycle environmental profile of the test item. No individual test or group of tests can be evaluated in isolation and the final assessment must consider the results of the developmental as well as safety qualification tests. 5.2 Safety Test Methods. . 5.2.1 Classificatio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILSTD14661983SAFETYCRITERIAANDQUALIFICATIONREQUIREMENTSFORPYROTECHNICINITIATEDEXPLOSIVEPIEAMMUNITION

链接地址:http://www.mydoc123.com/p-448314.html