1、1-1 MIL-STD-1441A (EA) 28 June 1994 SUPERSEDING MIL-STD-IMl(MU) 3 June 1968 M ILITARY STANDARD EQUIPMENT, LEAK DETECTION, HELIUM, FOR CHEMICAL MUNITIONS AMSC N/A FSC 4925 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or
2、 networking permitted without license from IHS-,-,-MIL-STD-1441 A (EA) FOREWORD 1. This Military Standard is approved for use by all Departments and Agencies of the Department of Defense. 2. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in imp
3、roving this document should be addressed to Technical Director, U.S. Army Edgewood Research, Development and Engineering Center, Attn: SCBRD-ENE (STD/SPECS/PKG), Aberdeen Proving Ground, MD 21 O1 0-5423, by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appeari
4、ng at the end of this document or by letter. 3. This standard is approved for use by all Departments and Agencies of the Department of Defense in the selection of equipment to determine leaks in chemical munitions. ii Provided by IHSNot for ResaleNo reproduction or networking permitted without licen
5、se from IHS-,-,-MI L-STD-1441 A (EA) CONTENTS Paraaraph PaGe 1 . SCOPE 1 1 . 1 Scope 1 1.2 Classification 1 2 . APPLICABLE DOCUMENTS (Not applicable) . 2 3 . DEFINITIONS 3 3.1 Definitions of Technical Terms 3 3.1 . 1 3.1.2 Helium Leak Detector . 3 Mass Spectrometer . 3 4 . GENERAL REQUIREMENTS . 4 4
6、.1 Description 4 4.2 Construction . 4 5 . 5.1 5.1 . 1 5.1.2 5.1.3 5.1.4 5.1.5 5.1.6 5.1 -7 5.1.8 5.1.9 5.1.1 O 5.1.1 1 5.1 . 12 5.1 . 13 5.1.14 5.1 . 15 5.2 DETAILED REQUIREMENTS . 5 Design criteria 5 Equipment 5 Leakdetector 5 Pumping equipment 5 Control panel 5 Worktable . 5 Monitoring . 6 Handlin
7、g 6 Contamination prevention . 6 Production requirement . 6 Detection cycle 6 Instrumentation 6 Cleaning 6 Safety of personnel . 6 Finish and nameplate 7 Manuals 7 Circuitry . 5 iii Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-1441A (EA) C
8、ONTENTS Paraaraph Page 6 . NOTES 8 Submission for approval . 8 Shipment and Storage 8 Subject term (key word) listing . 9 Changes from previous issue 9 6.1 Intended use 8 6.2 6.2.1 Excessive cost of equipment due to production requirements 8 6.3 6.4 Technical assistance 8 6.5 6.6 iv Provided by IHSN
9、ot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-1441 A (EA) 1. SCOPE 1 .I Scope. This standard covers various types and classes of helium leak detection equipment for use in testing the inert components of chemical munitions for leaks, and also the final clo
10、sure containing the chemical fill. -. s ing types and classes: 1.2 Classification. Helium leak detectors covered by this standard shall be of the follow- - - New leak detectors built for specific applications Rebuilt Government-furnished leak detectors, modified for specific applications For final c
11、losure of all munitions in the filling line Sniffer type to locate leaks to be reworked Type I Type II Class 1 - For heavy-walled munitions Class 2 - For thin-walled munitions Class 3 Class 4 - - 1 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MI L
12、-STD-1441 A (EA) 2. APPLICABLE DOCUMENTS (Not applicable to this document) 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-1441 A (EA) 3. DEFINITIONS 3.1 Definitions of Technical Terms. 3.1 .I Mass spectrometer- A mass spectrometer is an in
13、strument used to separate and determine the relative abundance of ions of different mass to charge ratio. Operation of the mass spectrometer depends on the deflection of ionized components of elements, compounds or mixtures, created by bombarding a sample in the gas phase with a beam of high-energy
14、electrons. The high-energy electrons knock one electron from a sample molecule, producing a singly charged positive ion referred to as the parent ion. This ion in turn fragments to form a variety of other fast-moving positive ion fragments, mainly sin- gly charged, which are stable only in the gas p
15、hase under the high-vacuum conditions used. These ions are directed through a magnetic field, which deflects their paths to an extent dependent upon their mass-to-charge ratios. The ions with the lowest mass-to- charge ratio are deflected the most. By varying the magnetic field, ions of any mass-to-
16、 charge ratio can be made to strike the detector. Since the ions are principally singly charged, the separation is primarily on the basis of mass. Taking into account the magnetic field and other characteristics of the instrument, the mass-to-charge ratio can be deter- mined and hence the mass of ea
17、ch fragment. A mass spectrum is determined by (1) vary- ing the magnetic field so that ions with progressively higher masses strike the detector, and (2) plotting the relative intensities (proportional to the numbers of ions of particular masses), as indicated by the detector, versus their mass-to-c
18、harge ratios. The mass-to- charge ratio of the parent ion is the molecular weight of the molecule. Therefore the mass spectrometer provides one of the best methods for obtaining very accurate molecular weights. More than that, however, the pattern of fragmentation and the masses of the par- ent ion
19、and of each fragment ion provide an excellent “fingerprint method for identifying the compound. 3.1.2 Helium leak detector. A helium leak detector is a mass spectrometer adjusted to detect helium gas. It can be used with a probe of helium to explore the outside of a system to detect a leak from insi
20、de a system, or it can be used inside a system to check for leaks from outside. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MI L-STD-1441 A (EA) 4. GENERAL REQUIREMENTS 4.1 Description. The equipment shall be capable of detecting helium leakage
21、 using a helium type mass spectrometer. The method used shall be placing the munition in a hood or chamber and evacuating either the interior of the munition or the chamber surrounding the munition. Helium shall be introduced into the space surrounding the munition or into the munition whichever is
22、applicable. If any leaks are present, helium will bedrawn through the leak into the evacuated space and then to the leak detector. The equipment shall be identified for acceptance or rejection in accordance with the requirements specified herein. 4.2 Construction. The equipment shall be ruggedly con
23、structed for full time production operation. It shall be capable of three-shift operation, eight-hours per shift. Regardless of type, the pumps shall be of sufficient capacity to complete a test cycle which will satisfy the requirement of 5.1 .I O. 4 Provided by IHSNot for ResaleNo reproduction or n
24、etworking permitted without license from IHS-,-,-MI L-STD-1441 A (EA) 5. DETAILED REQUIREMENTS 5.1 Desian criteria. The equipment described by this standard is intended to be used in production to screen components, determine leaks in filled munitions, and to conduct surveillance of existing stocks.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILSTD1441A1994EQUIPMENTLEAKDETECTIONHELIUMFORCHEMICALMUNITIONS 化学 军用 检漏 装置 PDF

链接地址:http://www.mydoc123.com/p-448304.html