《ARMY MIL-PRF-63045B-1997 MANUALS TECHNICAL PREPARATION OF DEPOT MANUALS FOR DEPOT TEST MEASUREMENT AND DIAGNOSTIC EQUIPMENT《技术手册 仓库测试 测量及诊断设备手册》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-63045B-1997 MANUALS TECHNICAL PREPARATION OF DEPOT MANUALS FOR DEPOT TEST MEASUREMENT AND DIAGNOSTIC EQUIPMENT《技术手册 仓库测试 测量及诊断设备手册》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-PRF-b3045B 999990b 2075233 YTb W I I NoTMEAS-MENT SENSITIVE MIL-PRF-63045B( TM) 17 July 1997 SUPERSEDING 15 November 1989 MIL-M-63045A( TM) PERFORMANCE SPECIFICATION MANUALS, TECHNICAL: PREPARATION OF DEPOT MANUALS FOR DEPOT TEST, MEASUREMENT AND DIAGNOSTIC EQUIPMENT This specification is approv
2、ed for use by the Department of the Army and is available for use by all departments and agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification contains the requirements for the preparation of depot manuals (DM) covering operation, maintenance, and calibration procedures for d
3、epot test, measurement and diagnostic equipment (TMDE). These requirements are applicable to manuals for equipment which is used for diagnostic and acceptance testing of field equipment items retumed to the depot for reconditioning. I i improving this document should be addressed to: Executive Direc
4、tor, USAMC Logistics Support Activity Acquisition Logistics Center, A“: AMXLS-Ap, Redstone Arsenal, AL 35898-7466, by using the self- Beneficial commnts (recommendations, additions, deletions) and any pertinent data which may be of use i addressed Standardization Document Improvement Proposal (DD Fo
5、rm 1426) appearing at the end of thi document or by letter. 1 I I AMSC A7280 AREA TMSS DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- _ MIL-PRF-63045B m 0b 2075234 33
6、2 m MIL-PRF-63045B (TM) 2. APPLICABLE DOCUMENTS 2.1 GeneraL The documents listed in this section are specified in section 3 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. while eve
7、ry effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in section 3 of this specification, whether or not they are listed. 2.2 Government documents 2.2.1 Specifications and standards The following s
8、pecifications and standards form a part of this specification to the extent specified herein. The issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICA
9、TIONS DEPARTMENT OF DEFENSE MILT-31000 - Technical Data Packages, General Spec 6cations r MIL-M-38793 - Manuals, Technical: Calibration Procedures, Preparation of STANDARDS DEPARTMENT OF DEFENSE MIL-STD- loo - Engineering Drawing Practices. MIL-STD-38784 - Manuals, Technical: General Style and Forma
10、t Requirements. MIL-STD-40051 - Technical Manual Preparation. (Unless otherwise indicated, copies of the above specifications and standards are available from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 191 11-5094.) 2.2.2 Other government documents, dr
11、awinm and publications The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. The issues are those cited in the solicitation (see 6.2). TM 39-1-1 - Joint Nuclear Weapons Publication Systems Operating Procedures, Specification
12、s and Standards (Copies of TM 39-1-1 are available from the U.S. Army Publications Distribution Center, ATN: ASQZ- SDC, 1655 Woodson Road, St. Louis, MO 63112-6181.) 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- - - - - _ - MIL-PRF-b3095B - 9999
13、906 2075235 279 MIL-PRF-63045B (TM) 2.3 Order of precedence In the event of a conflict between the text of this document and the references cited herein the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exempti
14、on has been obtained. 3. REOUIREMENTS 3.1 GeneraL Technical manuals shall consist of pertinent support data (including engineering or Commercial-off-the-shelf (COTS) manual the text shall be used oniy to support the diagrams as necessary for clarity. Functional diagrams shall depict the development
15、of each equipment 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-63045B 0b 2075238 T88 W MIL-PRF-63045B (TM) function from input to output, and shall show interconnection of the units. Signal levels, direction of flow, wave forms, etc, sha
16、ll be included as applicable. 3.3.8 Chapter 3 - Operating procedures 3.3.8.1 Section I - Setup instructions Site selection, unpacking, assembly, installation instructions, and special tools and requirements for installation inspection and pre-energizing procedures shall be provided in this section.
17、Instructions shall also be given for establishing normal, neutral, zero, center, on-off, or any required positions of each switch, control, or similar item before connecting to power when the equipment is in shutdown status. 3.3.8.2 Section II - Controls and indicators This section shall contain inf
18、ormation which is needed by the operator to properly identify, determine the function and use of, connect, operate, and protect the equipment being used. Controls and indicators shall be supported by illustrations which identify and locate ail operator controls and indicators. 3.3.8.3 Section IIi -
19、Turn-on and tum-off procedures This section shall contain instructions to place the equipment in operation, to operate the equipment in each mode of operation, to remove the equipment from operation and put it in standby condition, and to remove it from operation and put it in shutdown status. Instr
20、uctions shall be provided for turning the equipment off during an emergency (fire, hazard to personnel, loss of coolant, normal power, etc.), as applicable. 3.3.9 Chapter 4 - Maintenance requirements 3.3.9.1 Section I - Facilities, equipment, and material standards 3.3.9.1.1 Facilities. The faciliti
21、es required for maintenance of the test equipment, including special factors such as environment, shall be listed. 3.3.9.1.2 Special tools and equipment This portion shail contain the detailed description, instructions, and illustrations for special tools and equipment which are necessary to perform
22、 maintenance on the test equipment, including any items which must be locally fabricated. Specific dimensions and tolerances shall be supplied for tools and furtures. 3.3.9.1.3 Material standards. Unless otherwise specified by the contracting activity (see 6.2), this portion shail state that parts a
23、nd material used for replacement, repair, or modification shall meet all applicable equipment drawings and specifications. 3.3.9.2 Section II - Preventive maintenance This section shall contain a tabular listing of all periodic checks, services, and safety precautions, including intervals, necessary
24、 to maintain the test equipment in an operable state. References shall be made to applicable equipment lubrication orders (LO). If no applicable LOS are published, lubrication instructions shall be included in this section, in tabular format, with illustrated locations of lubrication points. 6 Provi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF63045B1997MANUALSTECHNICALPREPARATIONOFDEPOTMANUALSFORDEPOTTESTMEASUREMENTANDDIAGNOSTICEQUIPMENT

链接地址:http://www.mydoc123.com/p-447611.html