ARMY MIL-PRF-62678 B-2010 PUMP FUEL ELECTRICAL 12 AND 24 VOLT DIRECT CURRENT (METRIC)《(公制)12和24伏直流电动燃油泵》.pdf
《ARMY MIL-PRF-62678 B-2010 PUMP FUEL ELECTRICAL 12 AND 24 VOLT DIRECT CURRENT (METRIC)《(公制)12和24伏直流电动燃油泵》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-62678 B-2010 PUMP FUEL ELECTRICAL 12 AND 24 VOLT DIRECT CURRENT (METRIC)《(公制)12和24伏直流电动燃油泵》.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be addressed to U.S. Army RDECOM, Tank Automotive Research, Development and Engineering Center, ATTN: RDTA-EN/STND/TRANS MS #268, 6501 E. 11 Mile Road, Warren, MI 48397-5000 or emailed to DAMI_STANDARDIZATIONconus.army.mil. Since contact in
2、formation can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil. AMSC N/A FSC 2910 METRIC MIL-PRF-62678B 19 January 2010 SUPERSEDING MIL-PRF-62678A 22 November 1995 PERFORMANCE SPECIFICATION PUMP, FUEL, ELECTRICAL:
3、12 AND 24 VOLT DIRECT CURRENT (METRIC) This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers two types of electrically operated, in-line fuel pumps for use with 12 and 24 volt direct current (Vdc) automotive
4、 electrical systems (see 6.1). 1.2 Classification. Pumps are classified according to type, voltage, polarity, and metric thread designation, as specified (see 6.2 and 6.3). Type I - Standard duty (630 hours) Type II - Long life (5040 hours) Grade: 1 - 12 Vdc nominal 2 - 24 Vdc nominal Class: 1 - Neg
5、ative ground 2 - Positive ground Thread designation: 1 - 1/8-27 NPTF Female 2 - 1/4-18 NPTF Male 3 - 1/4-18 NPTF Male Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-62678B 2 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this s
6、ection are specified in sections 3 and 4 of this specification. This section does not include documents in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cauti
7、oned that they must meet all specified requirement documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document
8、to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). FEDERAL SPECIFICATIONS A-A-52557 - Fuel Oil, Diesel; for Posts, Camps, and Stations DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-DTL-5624 - Turbine Fuel, A
9、viation, Grades JP-4, JP-5 and JP5/JP-8 ST. MIL-DTL-13486/1 - Cable, Special Purpose, Electrical: Low Tension, Heavy-Duty, Single-Conductor, Unshielded. MIL-PRF-680 - Degreasing Solvent DEPARTMENT OF DEFENSE STANDARDS MIL-STD-461 - Requirements for the Control of Electromagnetic Interference Emissio
10、ns and Susceptibility. MS27142 - Connector, Plug, Electrical - Pin Contact No. 12, 14, and 16 A.W.G., Waterproof. (Unless otherwise indicated, copies of the above specifications and standards are available from the Document Automation and Production Service, Building 4/D, 700 Robbins Avenue, Philade
11、lphia, PA 19111-5094 or website: http:/assist.daps.dla.mil/quicksearch/.) 2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the is
12、sues of these documents are those cited in the solicitation or contract (see 6.2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-62678B 3 NUCLEAR REGULATORY COMMISSION (NRC) Code of Federal Regulations (CFR) - Title 10, Part 30 and 40 (Copi
13、es of the Code of Federal Regulations (CFR) are available from the U.S. Government Printing Office, 732 North Capitol St. NW, Washington, DC 20401 or website: http:/www.gpoaccess.gov/cfr/.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified
14、herein. Unless otherwise specified, the issues of the documents are those cited in the solicitation or contract (see 6.2). AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTM B117 - Salt Spray (Fog) Testing, Method of. ASTM D235 - Mineral Spirits (Petroleum Spirits) (Hydrocarbon Dry Cleaning Solv
15、ent) Specification For. ASTM D471 - Standard Test Method for Rubber Property-Effect of Liquids. ASTM D4814 - Standard Specification for Automotive Spark-Ignition Engine. ASTM G21 - Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi. (Application for copies of ASTM
16、 publications may be obtained from the American Society for Testing and Materials, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959 or website http:/www.astm.org/.) 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited here
17、in, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection in accorda
18、nce with 4.3. 3.2 Materials. Materials used shall be in accordance with the manufacturers materials specifications for pumps. The materials shall be capable of meeting all the operational and environmental requirements specified herein. Asbestos, cadmium, and radioactive material shall not be used i
19、n this item. Radioactive material is defined by CFR, Title 10, Parts 30 and 40, and other radioactive material in which the specific activity is greater than 0.002 microcuries per gram or the activity per item equals or exceeds 0.01 microcuries (see 4.6.1). Provided by IHSNot for ResaleNo reproducti
20、on or networking permitted without license from IHS-,-,-MIL-PRF-62678B 4 3.2.1 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible provided that the material meets or exceeds the oper
21、ational and maintenance requirements, and promotes economically advantageous life cycle costs (see 4.6.1). 3.3 Design and construction. The design and construction of the pumps shall be in accordance with figure 1 with the exception of the thread designation for inlet/outlet connections (see 6.2) an
22、d the electrical connector, which shall conform to MS27142-2 (see 4.6.1 and 4.6.2). 3.3.1 Filter. The pump shall incorporate a filter to protect the fuel supply system. The filter shall be freely removable for cleaning (see 4.6.1). 3.3.2 Inlet/outlet connections. The inlet and outlet connections sha
23、ll be threaded to interface with the mating threaded part and shall protrude from pump body enough to facilitate mechanical connection of fittings. Installation design shall allow 7.92 0.790 millimeters (mm) (0.312 0.031 inch (in.) variation between planes of faces of inlet and outlet (see 4.6.2 and
24、 6.2). 3.3.3 Electrical connector and cable. The electrical connector shall be as specified in the applicable drawing or standard (see 6.2). Cable shall be No. 14 American Wire Gauge (AWG) and shall conform to MIL-DTL-13486/1-5 or equivalent. A separate cable ground shall be used, with installation
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF62678B2010PUMPFUELELECTRICAL12AND24VOLTDIRECTCURRENTMETRIC 公制 12 24 直流 电动 燃油 PDF

链接地址:http://www.mydoc123.com/p-447597.html