1、 VIL-PRF-624LLA q0b 2044494 T87 I INCH-POUNDI MIL-PRF-624 1 1 A(AT) 7 July 1997 SUPERSEDING 5 July 1985 MIL-H-624 1 1 (AT) PERFORMANCE SPECIFICATION HEAT EXCHANGER, NBC SYSTEM GENERAL SPECIFICATION FOR This specification is approved for use by the U.S. Army Tank-automotive and Armaments Command, Dep
2、artment of the Army, and is available for use by ali Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification establishes the design, performance, inspection, and acceptance requirements for the heat exchangers used in Nuclear Biological Chemical (NBC) system of
3、the M1A1 and M1A2 tanks and its three major components: heat exchanger, condenser and precooler. 1.2 ClassZcation. Heat exchanger for the NBC system of the M1 Al and M1A2 tanks consists of the following (see 3.6): Component Drawing Heat exchanger 12336771 (for interface oniy) Condenser 12336772 (for
4、 interface oniy) Precooler 12336768 (for interface oniy) Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: U. S. Army Tank-automotive and Armaments Command, ATTN: AMSTA-TR-ElBLUE, Warren, MI 48397
5、-5000, by using the Standardization Document Improvement Proposai (DD Form 1426) appearing at the end of this document, or by letter. / AMSC N/A FSC 4U0 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permit
6、ted without license from IHS-,-,-* MIL-PRF-6241 lA(AT) 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additiona
7、l information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet ai speczed requirement documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2. i
8、Specifications. standards. and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications a
9、nd Standards (DoDISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS DEPARTMENT OF DEFENSE MIL-PRF-6241 l(AT)/lA - Heat Exchanger, NBC System, Heat Exchanger. MIL-PRF-62411(AT)/2A - Heat Exchanger, NBC System Condenser. MiL,-PRF-62411(AT)/3A - Heat Exchanger, NBC System
10、Precooler. STANDARDS DEPARIMENT OF DEFENSE MIL-STD-810 - Environmental Test Methods and Engineering Guidelines. (Unless otherwise indicated, copies of the above specifications, standards, and handbooks are available from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Phila
11、delphia, PA 191 11-5094.) 2.2.2 other Government documents. drawinas. and tmblications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. 2 Prov
12、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-624 1 1 A(AT) DRAWINGS ARMY 123 3 6768 12336771 123 3 6772 - Precooler (for interface only). - Heat Exchanger (for interface only). - Condenser (for interface only). (Copies of these drawings are av
13、ailable from the U.S. Army Tank-automotive and Armaments Command, ATTN: AMSTA-TR-EBLUE, Warren, MI 48397-5000.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specied, the issues of the documents which are DoD ad
14、opted are those listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2). AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ANSUASQC 21.4 ANSUNCSL 2540-1 AN
15、SUS of tests. Paragraph 4.6.9.1 4.6.9.1 4.6.9.2 4.6.9.3 4.6.9.4 4.6.9.5 4.6.9.6 4.6.9.7 4.6.9.8 4.6.9.9 4.6.9.10 4.6.9.11 4.6.9.12 4.6.6 Conformance Accept- X 8 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- PlIL-DRF-b2411A 9999906 2044502 983 m MI
16、L-PRF-624 1 1 A(AT) TABLE III. Classificatio Title Weight External leakage tntemai leakage Proof pressure Burst pressure Heat transfer Air pressure loss High temperature Low temperature Humidity Sand Dust salt fog Chemicals Cleaning spray Fungus Vibration First article Basic shock First article Gun
17、firing shock First article Ballistic shock Requirement 3.4.1 3.5.1.1 3.5.1.2 3.5.2 3.5.3 3.5.4 3.5.5 3.5.6.1.1 3.5.6.1.2 3.5.6.2 3.5.6.3 3.5.6.4 3.5.6.5 3.5.6.6 3.5.6.7 3.5.6.8 3.5.6.9 3.5.6.10 3.5.6.1 1 3.5.6.12 Df inspectio Inspection 4.6.3 1.6.4.1 1.6.4.2 4.6.5 4.6.6 4.6.7 1.6.8 4.6.9.1 4.6.9.1 4
18、.6.9.2 4.6.9.3 4.6.9.4 4.6.9.5 4.6.9.6 4.6.9.7 4.6.9.8 4.6.9.9 4.6.9.9.1 4.6.9.10 4.6.9.10.1 4.6.9.11 4.6.9.11.1 4.6.9.12 1 - Continued. Conformance First article X X X X X X X X X X X X X X X X X X X X X X X Examin- ation Accept- ance (1 00%) X X X 4.5 Conformance inspection. 4.5.1 Sampling. 4.5.1,
19、l Lot formation. An inspection lot shall consist of all the heat exchanger units of one type and part number, from an identifiable production period, from one manufacturer, submitted at one time for acceptance. 4.5.1.2 Sampling for examination. Samples for conformance examination shall be selected i
20、n accordance with ANSVASQC Z1.4. 9 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-624 1 1 A(AT) 4.5.2 Conformance examinations. 4.5.2.1 Classification of defects. For examination purpose, defects shall be classified as listed in table IV. Ca
21、tegory Critical Major: 101 102 103 104 Minor: 201 202 TABLE IV. Classification of defects. Defect None Assembly, incomplete (see 3.4). Dimensions affecting interchangeability, out of tolerance Identification marking, improper (see 3.7). Faulty workmanship affecting performance (see 3.8). (see 3.4 th
22、ni 3.4.2). Dimensions not affecting interchangeability, out of Faulty workmanship affecting appearance (see 3.8). tolerance (see 3.4 thru 3.4.2). Method of examination Visual SIE I/ Visual Visual SIE Visual - 1/ SE = Standard Inspection Equipment. 4.5.3 Conformance tests. 4.5.3.1 AcceDtance tests (i
23、00 Dercent). Each heat exchanger unit shall be subjected to the tests specified in table III. 4.5.3.2 Failure. Failure of any heat exchanger unit to pass any of the specified inspections shail be cause for the Government to refuse acceptance of the production quantity represented, until action taken
24、 by the contractor to correct defects and prevent recurrence has been approved by the Government. 4.6 Methods of inspection. 4.6.1 Materials. Conformance to 3.4 through 3.4.2 shall be determined by inspection of contractor records providing proof or certification that materials conform to requiremen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF62411A1997HEATEXCHANGERNBCSYSTEMGENERALSPECIFICATIONFOR 通用 规格 NBC 系统 热交换器 PDF

链接地址:http://www.mydoc123.com/p-447569.html