1、I INCH-POUND I AMENDMENT 1 21 April 2000 MI L-PRF-53137A(CR4) PERFORMANCE S P ECI FI CATI ON HEATER, ARMY SPACE (ASH), ELECTRIC POWERED, MULTIFUEL This amendment is approved for use within the USA Communications-Electronics Command, Logistics and Readiness Center, Department of the Army, with MIL-PR
2、F-53137A(CR4), dated 10 July 1997. PAGE 2 2.2.1, under STANDARDS, DEPARTMENT OF DEFENSE, delete “MIL-STD-462“ in its entirety. Add: “MIL-STD-2169B - High-Altitude Electromagnetic Pulse (HEMP) Environment. (Copies of the above classified military standard are available to personnel with the appropria
3、te security clearance from Headquarters US Army Communications-Electronics Command, Research, Development and Engineering Center, Command/Control and Systems, Integration Directorate - South, ATN: AMSEL-RD-C2-PD-E, 1 O1 08 Gridley Road, Suite 1, Ft Belvoir, VA 22060-581 7.)“ 2.2.2, last paragraph, a
4、t the end of the paragraph: change “AMSEL-LC-IEW-D-EE“ to “AMSEL-LC-CCS-G-GB“. PAGE 5 3.1, first sentence: delete “with either diesel or JP-8 fuels“ and substitute “with both diesel and JP-8 fuels“. At the end of the paragraph, add the following sentence: “Thresholds and objectives are identified in
5、 this document by TI and O, respectively.“ AMSC NIA FSC 4520 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. PAGE 1 OF 11 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MI L-PRF-53137A(CR4) AMENDMENT 1 3.3.1, delete
6、 the first sentence and substitute: “The heater shall deliver not less than 120,000 TI, 150,000 O British Thermal Units per Hour (BTUH) of clean air (see 3.8.7) when operated in the all fresh air mode, with an air temperature of O OF, at sea level up to 4,000 feet altitude, against an 0.5-inch water
7、 gauge (WG) pressure, using diesel fuel, grade Low Sulfur No. I-D conforming to A-A-52557.“ 3.3.2: Add the symbol “r“ after each dimension in this paragraph. Add the following sentence at the end of the paragraph: “Producing heaters that are smaller than the above dimensions is an objective of this
8、document.“ 3.3.3: line 1, delete “The heater shall weigh no more than 355 pounds II and substitute: “The heater shall weigh no more than 360 pounds r, 355 pounds O, i ncl ud i ng II. 3.4.1, line 3, delete “from -60 to +I 60 OF II, and substitute: “from -60 TI, -65 O to +I60 OF“. 3.4.2: line 3, delet
9、e “from -40 to +65 OF“ and substitute: II from -40 TI, -60 O OF unassisted start, -60 TI, -65 O OF assisted start to +65 OF, in all climatic conditions.“ PAGE 6 3.4.6: lines 4 and 5, delete “shall not exceed 85 db(A)“ and substitute: “shall not exceed 75 db(A) TI, 65 db(A) O II. Lines 5 and 6, delet
10、e “shall not exceed 65 db(A).“ and substitute: “shall not exceed 65 db(A) TI, 55 db(A) O.“ 3.4.7, delete in its entirety and substitute: “3.4.7 NBC comDatibilitv and Hiah-Altitude Electromaanetic Pulse (HEMP). The heaters will be mission essential in many applications; therefore, NBC contamination s
11、urvivability is required. The heaters will be decontaminable to negligible risk levels, will be hardened against the effects of chemical agents and decontaminants, and will be compatible with soldiers in full NBC-protective ensemble. The heaters must be HEMP survivable but operation through a HEMP e
12、vent is not required. The recycling of power to restore operations after a HEMP event is acceptable. When tested as specified in 4.6.8.2, the heater shall operate normally following a HEMP event (see 6.9).“ 3.5.1, first sentence: Delete “figure 1“ and substitute “figure I-a.“ 2 Provided by IHSNot fo
13、r ResaleNo reproduction or networking permitted without license from IHS-,-,-MI L-PRF-53137A(CR4) AMENDMENT 1 3.5.1, at the end of the paragraph add new sentence: “Conducted emissions (CEI02) on the heater power leads shall not exceed the applicable values shown on Figure 1 -b.“ 3.5.3, at the end of
14、 the last sentence: delete “cover.“ and substitute “cover (see 6.8). II 3.6, at the beginning of the paragraph add: “The heaters shall primarily operate using JP8 and diesel fuels DF-I, DF-2, and DF-A, as alternative fuels. The fuel system shall be easily accessible and allow for rapid draining.“ PA
15、GE 8 3.7.1, line 9, seventh sentence: delete: “and self concealing.“ 3.7.5, delete entire paragraph and substitute: “3.7.5 Mobilitvharkina devices. The heaters are required to be soldier-portable for short distances for repositioning purposes similar to the heaters currently in the field. The heater
16、 shall be mounted on a chassis with integral skids and tires, and the tires shall be mounted on wheels that are removable or retractable without the use of external tools. It is desirable to have wide, ski-like skids on the ASH for movement over mud and snow. It is also desirable to utilize non-pneu
17、matic (airless) tires, but they should be interchangeable with the fielded pneumatic tires. Provisions shall be made for securing the wheels to the heater when not installed for use. The heater shall have continuous handrails or minimum handles to assist in manual localized movement and positioning.
18、 The heater shall be provided with a parking stand to provide three-point support when the wheels are installed and with integral means to prevent movement of the heater when parked in level or specified inclined positions (see 3.7.6). Weight distribution of heater components shall provide a safe an
19、d stable configuration in all specified operating positions. PAGE 9 3.8.4, lines 3 and 4, delete “within 15-seconds“ and substitute: “within 18-seconds“. 3.8.5, delete entire paragraph and substitute: “3.8.5 Hiah temperature limit. A high temperature limit control shall shut down the burner when the
20、 temperature at the heater discharge outlet exceeds the pre-set limit and illuminate the panel indicator light. After a high temperature limit shutdown, the flame failure control (see 3.8.4) shall lock out the burner and require reset from the control panel. The high temperature limit control shall
21、reset automatically prior to the outlet 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MI L-PRF-53137A(CR4) AMENDMENT 1 temperature falling to 125 OF. The pre-set limit on the high temperature limit control shall be 200 +/- 10 OF.“ 3.8.7, Add the
22、following to the beginning of the paragraph: “The heater shall incorporate carbon monoxide (CO) sensors (primary and backup) which, when activated, will cause an audible and a visual alarm to be activated and will shut down the burner. The visual alarm shall remain on after system shutdown until it
23、is reset. The primary sensor shall be in the air discharge (supply) outlet of the heater, and the backup sensor shall be located on the remote control box.“ PAGE 10 3.9, add the following to the end of the paragraph: “The control circuit shall include a method of monitoring and controlling flame qua
24、lity, controlling valves, solenoids, and relays. Displays and indicators must be simple, straightorward, and easily read or recog n zed .II 3.9.5, delete in its entirety and substitute: “3.9.5 Remote control box. A hermetically sealed remote control box shall be provided. The control box shall conta
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF53137A12000HEATERARMYSPACEASHELECTRICPOWEREDMULTIFUEL 混合 燃料 电动 陆军 空间 加热器 ASHPDF

链接地址:http://www.mydoc123.com/p-447458.html