ARMY MIL-PRF-49307A-1997 COOLER-DEWAR GROUP OR-332 A OR-333 A.pdf
《ARMY MIL-PRF-49307A-1997 COOLER-DEWAR GROUP OR-332 A OR-333 A.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-49307A-1997 COOLER-DEWAR GROUP OR-332 A OR-333 A.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、METRICMIL-PRF-49307A(CR)3 JULY 1997SUPERSEDINGMIL-PRF-49307(CR)17 May 1989PERFORMANCE SPECIFICATIONCOOLER-DEWAR GROUP, OR-332/A, OR-333/AThis performance specification is approved for use by USACECOM, Department of theArmy and is available for use by all Departments and Agencies of the Department of
2、 Defense.1. SCOPE1.1 Scope . This performance specification covers only the Cooler-Dewar group to be usedin the AN/ASQ-170, Acquisition Designation Sight (TADS) and the AN/AAQ-11, Pilot NightVision Sensor (PNVS); herein referred to as the Cooler-Dewar.2. APPLICABLE DOCUMENTS2.1 General . The documen
3、ts listed in this section are specified in sections 3 and 4 of thisspecification. This section does not include documents in other section of this specification orrecommended for additional information or as examples. While every effort has been made toensure the completeness of this list, document
4、users are cautioned that they must meet allspecified requirements documents cited in sections 3 and 4 of this specification, whether or notthey are listed.2.2 Government documents .2.2.1 Handbooks . The following handbooks form a part of this specification to the extentspecified herein. Unless other
5、wise specified, the issues of these documents shall be those listed inthe Department of Defense Index of Specifications and Standards (DoDISS) and supplementthereto, cited in the solicitation (see 6.2). Handbooks are for guidance only and therefore are notmandatory.Beneficial comments (recommendatio
6、ns, additions, deletions) and any pertinent data which maybe of use in improving this document should be addressed to: HQ, USA Communications-Electronics Command, ATTN: AMSEL-LC-LEO-E-EP, Fort Monmouth, NJ 07703 by using theStandardization Document Improvement Proposal (DD Form 1426) appearing at th
7、e end of thisdocument or by letter.AMSC N/A FSC 5855DISTRIBUTION STATEMENT A . Approved for public release; distribution is unlimited.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-49307A2HANDBOOKSDEPARTMENT OF DEFENSEMIL-HDBK-454 - Standard
8、 General Requirements for ElectricalEquipment.(Unless otherwise indicated, copies of the above specifications, standards and handbooksare available from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D,Philadelphia, PA 19111-5094).2.2.2 Other Government documents, drawings an
9、d publications . The followingGovernment documents, drawings and publications form a part of this specification to the extentspecified herein.PURCHASE DESCRIPTIONDEPARTMENT OF DEFENSEPD-0182-001A - Cooler, Cryogenic, Long Life One Watt Integral,HD-1033D/UADRAWINGSUSACECOM5008609 - Installation and I
10、nterface Dimensions, Mechanical Cryogenic cooler, HD-1033D/UASM-C-806033 - Bellows, CoolerSM-D-806561 - Detector -Dewar DT-594( )/UA(Copies of Specifications, standards, drawings and publications required by contractors inconnection with specific procurement functions should be obtained from the pro
11、curing activity oras directed by the contracting officer).2.3 Order of precedence . In the event of a conflict between the text of this document andthe references cited herein, the text of this document takes precedence. Nothing in this document,however, supersedes applicable laws and regulations un
12、less a specific exemption has beenobtained.3. REQUIREMENTS3.1 First article . When specified (see 6.2.C), the samples shall be subjected to a first articleinspection in accordance with 4.2.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-49307
13、A33.2 Materials . The contractor shall select materials that are fully capable of meeting all ofthe operational and environmental requirements specified herein. The materials specified in theapplicable drawings are recommended, but are not mandatory. Selection criteria for the class,grade or type pa
14、rt shall ensure that the material will be able to perform its intended function whenit is assembled. Verification of the supplier meeting the overall performance requirements shall bethe governing acceptance standard. Recovered materials shall be used to the maximum extentpossible.3.3 Description .
15、The Cooler-Dewar is a component of the AN/ASQ-170, TargetAcquisition Designation Sight (TADS) and the AN/AAQ-11, Pilot Night Vision Sensor (PNVS),an infrared detection system used aboard military aircraft. The cooler-Dewar group consists of aninfrared Detector-Dewar (DT-594/UA), a Cryogenic Cooler (
16、HD-1033D/UA), and a thermalconductor with associated fastening hardware. This group requires further alignment prior tofinal installation in TADS/PNVS.3.3.1. Common module selection . The detector and cooler components shall meet therequirements of their respective documents and be inspected in acco
17、rdance with the verificationassurance provisions of these documents prior to assembly of the Cooler-Dewar Group,OR-333/A (see 6.2.k).3.3.2 Thermal conductor . The bellows thermally connects the cooler cold finger to theDetector-Dewar. The recommended parameters and installation procedure for the the
18、rmalconductor can be found on Drawing SM-C-806033. An alternate definition and installationprocedure of the thermal conductor may be developed by the contractor, but shall be approved bythe Government prior to use (see 6.2.b).3.3.3 Dimensions . To ensure that items produced IAW this specification ac
19、curatelyinterface with existing hardware, dimensions and dimensional tolerances of the Detector-Dewarand Cooler shall be in accordance with Drawings SM-D-806561 and 5008609, respectively.3.4 Design criteria . The devices built IAW this specification shall be designed to ensureform, fit, function and
20、 interface requirements, as specified herein, are met.3.5 Performance characteristics .3.5.1 Defective Elements . Unless otherwise specified herein, the Detector-Dewar shall beoperated at 80 K (+5, -20 K). The Detector-Dewar shall contain no more than 12 defectiveelements. Of the 12 defective elemen
21、ts, no more than 4 may be hard defects. In the central 18elements of the array there shall be no hard defects and no more than 2 soft defects. The central36 elements shall contain no hard defects and no more than 4 soft defects. A maximum of twohard defects may be located in elements 1-72, and a max
22、imum of two may be located in elements109-180. Hard defects shall be separated from one another by at least 4 elements and shall beelectrically strapped to an adjacent element with common ground. Soft defects located within thecentral 36 elements shall be separated from any other defect by at least
23、4 non-defective channels.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-49307A4Soft defects shall not be strapped unless the strapping is from an adjacent hard defect at the end ofa group of 5 commonly grounded elements. (Perform 4.5.1 for a
24、cceptance).3.5.2 Detector Microphonics . When cooled to a temperature of 60-80 K, biased inaccordance with paragraph 3.5.2.1 and vibrated in accordance with paragraph 3.6.3, all elementsof the Detector-Dewar shall have no noise peaks above the white noise reference value greaterthan 6dB from 300 to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF49307A1997COOLERDEWARGROUPOR332AOR333APDF

链接地址:http://www.mydoc123.com/p-447349.html