ARMY MIL-PRF-49293 B-2011 RADIAC SET AN PDR-75.pdf
《ARMY MIL-PRF-49293 B-2011 RADIAC SET AN PDR-75.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-49293 B-2011 RADIAC SET AN PDR-75.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-PRF-49293B 13 September 2011 SUPERSEDING MIL-PRF-49293A03 July 1997PERFORMANCE SPECIFICATION RADIAC SET, AN/PDR-75 This performance specification is approved for use by USACECOM, Department of the Army and is available for use by all Departments and Agencies of the Department of Defense. 1. SCO
2、PE. 1.1 Scope. This performance specification covers the Radiac Set, AN/PDR-75. 2. APPLICABLE DOCUMENTS. 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents in other sections of this specification or recom
3、mended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Gover
4、nment documents. 2.2.1 Specifications, Standards and Handbooks. The following specifications, standards and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the Department of Defense Index of Specific
5、ations and Standards (DoDISS) and supplement thereto, cited in the solicitation (See 6.2). Handbooks are for guidance only and therefore are not mandatory. AMSC N/A FSC 5855 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Comments, suggestions, or questions on this
6、document should be addressed to: Communications-Electronics RDEC ATTN: RDER-PRQ-QE Fort Monmouth, NJ 07703-5201or emailed to mike.g.williamsus.army.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/as
7、sist.daps.dla.mil. INCH-POUND Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-49293B - 2 - HANDBOOKS DEPARTMENT OF DEFENSE MIL-HDBK-454 Standard General Requirements for E
8、lectronic Equipment. MIL-HDBK-781 Reliability Design Qualification and Production Acceptance Tests. (Unless otherwise indicated, copies of the above specification, standards and handbooks are available at https:/assist.daps.dla.mil.) 2.2.2 Other Government documents, drawings and publications. The f
9、ollowing Government documents, drawings, and publications form a part of this specification to the extent specified herein. Unless otherwise specified, the issues should be those in effect on the date of the solicitation. PUBLICATIONS EL-CP-5111-0002A - Nuclear Survivability Requirements for Detecto
10、r, Radiac DT-236/PD and Computer Indicator, CP-696( )UD, 18 March 1974 TB 9-6665-286-35 - Calibration Procedure for Radiac Set, AN/PDR-75 MK-2512/PDR-75 - Maintenance Kit (Copies of documents, drawings and publications required by contractors in connection with specific procurement functions should
11、be obtained from the procuring activity or as directed by the contracting officer). 2.3 Non-Government Publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents which are DoD adopted are those listed in
12、the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS are the issues of the documents cited in the solicitation. (See 6.2). AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ANSI C63.14-1994 - Electromagnetic Compatibility (EMC) et
13、c.; Dictionary for Technologies of (Application for copies should be addressed to http:/www.ansi.org/contact_us/contact_us.aspx?menuid=contact). 2.4 Order of Precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes prec
14、edence. Nothing in this Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-49293B - 3 - document, however, supersedes applicable laws and regulations unless a specific exempt
15、ion has been obtained. 3. REQUIREMENTS 3.1 AN/PDR-75 System Description. The AN/PDR-75 Radiac Set consists of the Computer Indicator Radiac CP-696/PDR-75 (Reader), the Carrying Case CY-8420/PDR-75 and three power cables. The Dosimeter (DT-236/PDR-75) is used with but not a part of the Radiac Set. It
16、 measures neutrons and gammas from nuclear detonations and residual neutrons and gammas from contamination. The dosimeter is contained in a two-part case and is a type that can be worn the same as a wristwatch. The Reader is capable of opening, reading and closing the dosimeter. Two separate reading
17、 elements are contained in the Reader, consisting of an ultraviolet light source, filters and a light detector for reading the gamma dose, plus a constant current source and a peak reading voltmeter for reading the neutron dose. A digital meter displays a combined reading of the two separate reading
18、 elements. The range of the system is zero to one thousand centigrays (cGy) (threshold) and zero to two thousand cGy (objective). The CP-696/PDR-75 is powered from a 24 volt DC source. 3.1.1 Functional Description. The CP-696/PDR-75 Radiac Computer Indicator is used to measure the accumulated neutro
19、n and gamma radiation recorded by the Dosimeter DT-236/PDR-75. The Radiac Detector DT-236/PDR-75 is worn by personnel who may be exposed to radiation from nuclear weapons. 3.1.2 First Article. When specified in the contract (See 6.2), the contractor should furnish first article units for inspection
20、(See 4.3). 3.2 Materials. The contractor should select the materials, but the materials and parts used should be fully capable of meeting all of the operational and environmental requirements specified herein. The materials specified in the applicable drawings are recommended, but are not mandatory.
21、 Selection criteria of the class, grade or type part should be that the material will be able to perform its intended function when it is assembled. Verification of the supplier meeting the overall performance requirements should be the governing acceptance standard. Recovered materials should be us
22、ed to the maximum extent possible. 3.2.1 Bonds and Grounds. Bonding for equipment current path returns, RF potentials and shock hazards should be installed so that expansion, contraction, or movement incident to normal service use and maintenance will not break or loosen the connections. Surface pre
23、paration for bonds and grounds should be accomplished by removing all anodic film, grease, paint, lacquer or other high resistance coatings from the immediate areas of contact. The equipment finish should be restored to its original condition. The DC resistance of bonds and grounds should not exceed
24、 25.0 milliohms. (See 4.8.1). 3.2.2 Cables and Connectors. Shielded cables, when required, should have a shield weave providing 90% coverage. For guidance, refer to requirement 11 of MIL-HDBK-454. Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF49293B2011RADIACSETANPDR75PDF