1、MIL-PRF-49LCOD E 0b 2087232 242 Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving the document should be addressed to: HQ, USA Communications-Electronics Command, ATTN: AMSEL- LC-LEO-E-EP Fort Monmouth, NJ 07703-5023 by using the Stan
2、dardization Document Improvement Proposal (DD Form 1426) appearing at the end of thi document by letter. 4 , PERFORMANCE SPECIFICATION ENTRANCE HOUSING ASSEMBLY VIEWER, DRIVERS, NIGHT VISION, AN/VVS-2 (V) I INCH-POUND MIL-PRF-49150D (CR) MIL-E-49150C (CR) 26 May 1992 This specification is approved f
3、or use by US Army Communications- Electronics Command, Department of the Army, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the Entrance Housing Assembly which is part of Viewer, Drivers Night Vision, AN/VVS-Z(V)
4、. 1.2 Classification. Entrance housing assemblies covered by this specification must be the following types as specified; Type 1 Entrance Window and Mirrcr Housing Assembly for Type II .Prism Objective Housing Assembly for AN/VVS-2(V)2A Type III Prism Objective Housing Assembly, for AN/VVS-2(V)3 Typ
5、e IV Prism Objective Housing Assembly for AN/VVS-2(V)4 AN/VVS-2 (V) 1A (M60 Application) (XM-1 Application) (FVS Application) (Paladin Application) 2. APPLICABLE DOCUMENTS DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Copyright Communications - Electronics Command
6、 Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-flIL-PRF-47150D = 999990b 2087233 189 H MIL-PRF-4 9150D (CR) 2.1.1 Reference documents, drawings and publications. The following other Government documents, drawings and publica
7、tions form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation (see 6.2.e). DRAWINGS USA COMMUNICATIONS-ELECTRONICS COMMAND SM-D-77133/SM-D-771476 - Entrance Housing Assembly (V1A SM-D-77143/SM-D-771486 - Prism Objective
8、Housing Assembly Configuration) (V2A/V3 Configuration) 5005814 - Prism Objective Housing Assembly (V4 Configuration) (Copies of specifications, standards, drawings, and publications required by contractors in conr.ection with specific procurement functions should be obtained from the procuring activ
9、ity or as directed by the contracting officer.) 2.2. Order of precedence. In the event of a conflict between the text of this specification and the references cited herein, the text of this specification takes precedence. Nothing in this document, however, supersedes applicable laws and regulations
10、unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Description. The entrance housing assembly is herein referred to as the entrance assembly. The entrance assembly is the portion of the drivers viewer outside the vehicle. It directs the line of sight to the objective lens. 3.2 Constr
11、uction. The entrance assembly shall be constructed to assure compliance with the contract configuration baseline and in accordance with the following drawings as applicable (see 6.2.d): Type 1 SM-D-771333/SM-D-771476 Entrance Housing Type II/III SM-D-771434/SM-D-771486 Prism Objective Type IV 500581
12、4 Prism Objective Housing Assembly Assembly Housing Assembly 3.3 First arricle testing (FAT). When specified in the contract (see 6.2.c and 6.2.g) the contractor shall furnish unit(s) for FAT inspection and approval (see 4.2). 2 Copyright Communications - Electronics Command Provided by IHS under li
13、cense with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-flIL-PRF-47150D m 0b 2087234 O15 MIL-PRF-49150D (CR) 3.4 Materials. The contractor shall select parts and materials that are fully capable of meeting all of the operational and environmental requirement
14、s specified herein. The materials specified in the applicable drawings are recommended, but not mandatory. Selection criteria of the class, grade or type part shall ensure the material will be able to perform its intended function when it is assembled. Verification of the supplier meeting the overal
15、l performance requirements shall be the governing acceptance standard. Recovered materials shall be used to the maximum extent possible. 3.5 Performance characteristics. 3.5.1 Angular deflection. An optical ray perpendicular to the mounting flange shall be deflected through an angle of 108, k 2 degr
16、ees for Type I and 90, k 2 degrees for Type II, Type III and Type IV. 3.5.2 Resolution. The resolution shall be 7 line- pairs/milliradian or better when rotated I15 degrees about a center 35mm from the mounting flange and a telescope of 8 power (X) or greater with a 30mm aperture is used. The telesc
17、ope may be focused a maximum of 0.03 diopter from infinity for best focus. 3.5.3 Transmission. The transmission shall be 80 percent minimum over the entire aperture in the spectral region defined by a 2854K, f 200K source and an S-20 extended-red (ER) detector. 3.6 Environmental. 3.6.1 Temperature E
18、xtremes. The entrance assembly shall not be damaged nor suffer degradation of performance (3.10.1 and 3.10.4) after being subjected to storage at +68C and -51OC. The entrance assembly shall not be damaged nor suffer degradation of performance (see 3.10.1 and 3.10.4) after being subjected to repetiti
19、ve temperature changes between +23C and -51C within 5 minutes and between +23“C and +68OC within 5 minutes. The soak time at each temperature extreme shall be sufficient for the entire entrance assembly to achieve stabilization at the specified temperature. Time for temperature stabilization is defi
20、ned as the amount of time required for the most internal part of the unit under test to achieve the specified temperature. 3.6.2 Humidity. The entrance assembly shall not be damaged nor suffer degradation of performance after being subjected to +68“C and 94 i4 percent humidity (see 3.10.1 and 3.10.4
21、). 3.6.3 Immersion. The entrance assembly shall not be damaged (see 3.10.1) after being immersed in fresh water to a depth of not less than 3 feet for a period of not less than 30 minutes. The entrance assembly shall be pre-conditioned by exposure to temperature of +45“C k3C for a period of 2 hours
22、prior to being immersed in the fresh water at a temperature of +18C f5C. 3.6.4 Vibration. The entrance assembly shall not be damaged nor suffer degradation of performance (see 3.10.1 and 3.10.4) after being subjected to vibration equivalent to that encountered in tracked vehicles during 5000 miles o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF49150D1999ENTRANCEHOUSINGASSEMBLYVIEWERDRIVER SNIGHTVISIONANVVS2VPDF

链接地址:http://www.mydoc123.com/p-447313.html