1、 INCH - POUND MIL-PRF-32424 13 September, 2012 PERFORMANCE SPECIFICATION HEATER, SPACE - CONVECTIVE, SELF-POWERED, LIQUID FUEL, SHC 90K This performance documentation is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This documentation covers the p
2、erformance and acceptance requirements for a self-powered, liquid fuel burning, convective space heater 1.2 Classification. Space Heater Convective (SHC 90K), 90,000 BTU/hr Comments, suggestions, or questions on this document should be addressed to U.S. Army Soldier Systems Center, Natick, MA 01760-
3、5018 or emailed to Joseph.A.Mackoul.civMail.Mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.dla.mil . AMSC N/A FSC 4520 Provided by IHSNot for ResaleNo reproduction or networking permitted wi
4、thout license from IHS-,-,-MIL-PRF-32424 2 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional informatio
5、n or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. The following d
6、ocuments form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) cited in the solicitation. Unless otherwise specified, the issues of
7、 documents not listed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2). MIL-STD-810 Environmental Test Methods and Engineering Guidelines (Copies of these documents are available online at https:/assist.dla.mil or from the Standardization Document Order Desk, 700 Rob
8、bins Avenue, Building 4D, Philadelphia, PA 19111-5094) 2.3 Non-Government Publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents which are DoD adopted are those listed in the issue of the Department o
9、f Defense Index of Specifications and Standards (DoDISS) cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2). AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINE
10、ERS (ASHRAE) ASHRAE 51 Laboratory Methods of Testing Fans for Rating Purposes (Application for copies should be addressed to American Society of Heating, Refrigeration and Air Conditioning Engineers, 1791 Tullie Circle N.E., Atlanta, GA 30329. The web address is http:/www.ashrae.org .) AMERICAN SOCI
11、ETY FOR TESTING AND MATERIALS (ASTM) ASTM D2156 Standard Test Method for Smoke Density in Flue Gases from Burning Distillate Fuels (Application for copies should be addressed to American Society for Testing and Materials, 100 Barr Harbor Dr., West Conshohocken, PA 19428-2959. The web address is http
12、:/www.astm.org .) 2.4 Order of Precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obta
13、ined. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-32424 3 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to a first article inspection in accordance with 4.1.1. 3.2 Conformance and end item examin
14、ation. Items furnished under this specification shall be subjected to conformance inspection and end item examination in accordance with 4.1.2 and 4.1.3. 3.3 Operating requirements. The heater shall satisfy the following user-oriented requirements. 3.3.1 Description. The SHC 90K shall be a 90,000 BT
15、U, lightweight, portable, multi-fuel, self-powered heater that operates outside military tents and provides forced hot air recirculation via sealed, detachable, quick connect, flexible air ducts, without the need for an external power supply. The SHC 90K shall operate on diesel and JP-8 fuels and ge
16、nerate its own internal electrical power without any moving parts. Fuel ignition will be accomplished by a one-switch startup procedure on a remote control located inside the tent. The remote control will have a visual display to show heater functions and fault codes. Heater operation will include c
17、ompletely automatic safety and temperature controls as well as built-in troubleshooting diagnostics. The SHC 90K will be equipped with an internal fuel tank to provide a minimum of 15 hours of continuous operation and will have the capability to operate on an external fuel supply as well. It will ha
18、ve a protective enclosure that can withstand extreme environmental and field conditions. It will be forkliftable and have handrails/handles and wheels if required to support local movement and positioning. 3.3.1.1 Heat output. The heater shall provide a minimum of 90,000 BTU/Hr (1,500 BTU/hr) heat o
19、utput when the thermostat is not satisfied using JP-8 fuel and a maximum of 60,000 BTU/Hr (+4,000 BTU/hr) heat output with JP-8 when the thermostat is satisfied at altitudes up to 5,000 ft. Heat output shall be derated 15% at altitudes up to 10,000 ft. 3.3.1.2 Indicated efficiency. The burner system
20、 shall operate, during any temperature setting, at a minimum of 80 % indicated combustion efficiency. 3.3.1.3 Burner smoke spot. After 5 minutes of burner operation the heater shall not produce a smoke spot number greater than 3, per ASTM D2156, in any mode of operation under any identified performa
21、nce test condition. 3.3.1.4 Fuel capability. The heater shall be safely operated with all of the fuels listed in Table I at the corresponding environmental conditions, with no operator adjustments required to accommodate varying fuel types. The primary fuel will be JP-8 and the alternate fuels will
22、be K-1, DF-A, DF-1, JP-5 and DF-2. TABLE 1. Compatible Fuels Ambient Temperature Range National Stock Number Military Symbol CONUS Above +25F 9140-01-286-5294 DF-2 Above +10F 9140-01-286-5286 DF-1 Above -25F K-1 Above -60F 9130-01-031-5816 JP-8 Above -60F 9140-01-286-5283 DFA Provided by IHSNot for
23、ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-32424 4 3.3.1.5 Operational temperature range. The heater shall operate in a temperature range of +60F to -60F. 3.4 Fuel system. The fuel system shall permit the heater to operate continuously without flooding. The he
24、ater shall operate from either an integral fuel tank or from an external fuel supply. A fuel system diagram shall be mounted on the heater. 3.4.1 Integral fuel tank. The heater shall have an integral fuel tank of sufficient capacity to provide a minimum 15 hours (Threshold) and 24 hours (Objective)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF324242012HEATERSPACECONVECTIVESELFPOWEREDLIQUIDFUELSHC90KPDF

链接地址:http://www.mydoc123.com/p-447173.html