1、 INCH - POUND MIL-PRF-32109(CR) 16 September 2002 PERFORMANCE SPECIFICATION FLOODLIGHT SET, ELECTRIC, PORTABLE 1. SCOPE 1.1 Scope. This specification covers a floodlight set that provides a minimum of 160,000 mean lumens mounted on an adjustable height floodlight mast. 2. APPLICABLE DOCUMENTS 2.1 Ge
2、neral. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the complete
3、ness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards,
4、 and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation (see 6.2). STAND
5、ARDS DEPARTMENT OF DEFENSE MIL STD-209 - Slinging and Tie down Provisions for Lifting and Tying Down Military Equipment. MIL-STD-810 - Environmental Test Methods and Engineering Guide Lines MIL STD-1472 - Department of Defense Design Criteria Standard, Human Engineering (Unless otherwise indicated,
6、copies of the above specifications, standards are available from the Document Automation and Production Service, Building 4D (DODSSP/ASSIST), 700 Robbins Avenue, Philadelphia, PA 19111-5094). Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in im
7、proving this document should be addressed to: US Army Communications-Electronics Command, ATTN: AMSEL-LC-LEO-E-EP, Fort Monmouth, NJ 07703-5023 by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC FSC 6230 D
8、ISTRIBUTION STATEMENT A. Approved for public release; distribution is unliCopyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-mited. MIL PRF-32109(CR) 2.3 Non-Government publications.
9、 The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of the documents which are DoD adopted are those listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not list
10、ed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2). ASTM International ASTM D4169 - Containers and Systems, Shipping, Performance Testing of (Application for copies should be addressed to the ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocke
11、n, PA 19428-2959. Telephone: (610) 832-9585, Fax: (610) 832-9555.) NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) AB 1 - Molded Case Circuit Breakers. WD 5 - Specific- Purpose Wiring Devices. (Application for copies should be addressed to Global Engineering Documents, 15 Inverness Way East, En
12、glewood, CO 80112. Telephone 1-800-854-7179.) NATIONAL FIRE PROTECTION ORGANIZATION (NFPA) NFPA 70 - National Electrical Code. (Application for copies should be addressed to NFPA, 1 Batterymarch Park, P.O. Box 9101, Quincy, MA 02269-9101. Telephone (617) 770-3000, Fax (617) 770-0700) SOCIETY OF AUTO
13、MOTIVE ENGINEERS (SAE) SAE Aerospace Recommended Practice (ARP) 1328, Rev A (Application for copies should be addressed to Society of Automotive Engineers, Inc., 400 Commonwealth Drive, Warrendale, PA 15096.) UNDERWRITERS LABORATORIES, INC. (UL) UL 489 - Molded-Case Circuit Breakers and Circuit-Brea
14、ker Enclosures. UL 498 - Electrical Attachment Plugs and Receptacles (Application for copies should be addressed to comm. 2000, 1418 Brook Drive, Downers Grove, IL 60515. Telephone 1-888-853-3503.) 2.4 Order of precedence. In the event of a conflict between the text of this document and the referenc
15、es cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 2Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproducti
16、on or networking permitted without license from IHS-,-,-MIL PRF-32109(CR) 3. REQUIREMENTS 3.1 Description. The man portable, externally powered floodlight set (hereinafter called “floodlight set”) shall consist of a light source(s) that provides a minimum of 160,000 total mean lumens, lights shall b
17、e mounted on a mast, provision shall be made for mounting on various soil conditions, including frozen ground, soft mud and sand. All components shall be designed/designated for outdoor use. Floodlight set shall include durable containers for transport and storage of floodlight components. Assembly
18、and operation must be practical for personnel wearing leather work gloves, cold weather gloves, mittens, or MOPP4. Time required to unpack and erect floodlight shall not exceed 1 hour, personnel requirements not to exceed four people. Floodlight shall be operable with both 110 VAC and 220VAC single-
19、 phase power sources. Maximum power consumption shall not exceed 3KW. The floodlight set shall be complete with all components and accessories necessary for operation and storage under the conditions specified herein. The contractor shall be responsible for design of the floodlight set. When first a
20、rticle is specified (6.2), sample(s) shall be subject to First Article Inspection (4.2). 3.1.1 Tie down/lift points. Tie down devices shall be provided to allow tie down of containers for transportation. Lifting points shall be provided to allow lifting of the floodlight set containers. Lifting and
21、tie down attachments shall conform to MIL-STD-209, for type I equipment. Lifting and tie down provisions shall be indicated by a plate conforming to the vehicle shipping data plate described in MIL-STD-209. The lift and tie down provisions shall be identified by decals, in letters not less than 1 in
22、ch in height. 3.2 First article. The manufacturer shall furnish a sample(s) for first article inspection, test, and approval when specified in the contract or purchase order (see 6.2). 3.3 Operating requirements. The floodlight set shall conform to the following operating requirements: 3.3.1 Weight.
23、 The maximum weight of any container shall not exceed 147 lbs. (147 lbs is under the four man lift; and above the one man and three woman lift.) Total weight of all containers shall not exceed 1000 lbs. 3.3.2. Dimensions/volume of all containers. Transport/storage containers shall be man portable an
24、d shall be stowable in an M998A1 HMMWV. Acceptable dimensions for transport/storage containers include 40 inches by 50 inches by 32 inches high. 3.3.3 Test of containers. Containers shall be tested as specified in 4.5.2. 3.3.4 Operating Procedure Test. When tested as specified in 4.5.3, the floodlig
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF321092002FLOODLIGHTSETELECTRICPORTABLE 手提 电动 照明灯 PDF

链接地址:http://www.mydoc123.com/p-447111.html