ARMY MIL-PRF-32026-1998 CONTAINERIZED KITCHEN《集装厨房》.pdf
《ARMY MIL-PRF-32026-1998 CONTAINERIZED KITCHEN《集装厨房》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-32026-1998 CONTAINERIZED KITCHEN《集装厨房》.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、8 MIL-PRF-3202b Ob 20bb583 770 c I INCH-POUND I MIL-PRF-32026(GL) 03 June 1998 PERFORMANCE SPECIFICATION CONTAINERIZED KITCHEN This specification is approved for use by the Natick Research, Development and Engineering Center, Department of the Army, and is available for use by all Departments and Ag
2、encies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers a field kitchen, configured within an 8-foot by 8-foot by 20-foot International Organization for Standardization (ISO) container, that provides a rapidly deployable food preparation capability (see 6.1). 2. APPLICABLE
3、 DOCUMENT3 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to en
4、sure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Swcifications and standards. The following specifications and sta
5、ndards form part of this document to the extent provided herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and the supplement thereto, cited in the solicitation (see 6.2). : Bene
6、ficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: U.S. Army Natick Research, Development and Engineering Center, A“: SSCNC-WEF, Natick, MA 01760-5018 by using the Standardization Document Improvement
7、Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC N/A FSC 7360 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NIL-PRF-32026 W 9999906 2066582 827 DEPARTMENT OF DEFENSE MIL-C-53072 MIL-STD-209 MIL-STD-8 10 - Chemical Ag
8、ent Resistant Coating (CARC) System Application Procedures and Quality Control Inspection - Slinging and Tiedown Provisions for Lifting and Tying Down Military Equipment - Environmental Test Methods and Engineering Guidelines (Unless otherwise indicated, copies of the above specifications and standa
9、rds are available from the Standardization Documents Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19 1 1 1-5094.) 2.2.2 Other Government documents. The following other Government documents form a part of this document to the extent specified herein. Unless otherwise specified, the i
10、ssues are those cited in the solicitation (see 6.2). NATIONAL, INSTITUTE FOR OCCUPATIONAL SAFETY AND HEALTH (NIOSH) NOSH Manual of Analytical Methods (NMAM) (Application for copies should be addressed to Superintendent of Documents, Government Printing Office, Washington, D.C. 20402-9325.) OCCUPATIO
11、NAL SAFETY AND HEALTH ADMINISTRATION (OSHA) Directive TED 1-15 - OSHA Technical Manual (OTM) Standard No. 110.l - Air Contaminants (Application for copies should be addressed to U.S. Department of Labor/OSHA, OSHA Publications, P.O. Box 37535, Washington, D.C. 20013-7535.) 2.3 Non-Government Dublica
12、tions. The foliowing documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents which are DoD adopted are those listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not lis
13、ted in the DoDISS are the issues of the documents cited in the solicitation (see 6.2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-PRF-3202b b 20bb583 763 9 L MIL-PRF-3 2026( GL) AMERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS (ACG
14、IH) Threshold Limit Values and Biological Exposure Indices (Application for copies should be addressed to American Conference of Govemental Industrial Hygienists, 1330 Kemper Meadow Drive, Cincinnati, OH 45240.) INTERNATIONAL ORGANIZATION FOR STANDARDIZATION (ISO) Standard 668 - Freight containers -
15、 External dimensions and ratings Standard 1161 - Series 1 freight containers - Corner fittings - Specification Standard 8323 - Freight containers - Air/surface (internodal) general purpose containers - Specification and tests Standard 1496-1 - Series 1 freight containers - Specification and testing
16、- Part I : General cargo containers (Application for copies should be addressed to American National Standards Institute, 1430 Broadway, New York, NY 10018.) NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) Standard No. 70 - National Electrical Code Standard No. 701 - Fire Test for Flame-Resistant Textil
17、es and Films (Application for copies should be addressed to National Fire Protection Association, One Battery March Park, Quincy, MA 02269-9101.) NSF INTERNATIONAL Standard No. 2 - Food Service Equipment (Application for copies should be addressed to NSF International, 3475 Plymouth Road, Ann Arbor,
18、 MI 48 105.) 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.
19、 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.1.1. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- - MIL-PRF-32026 9999906 2066584 6TT W b Item# Descripti
20、on Quantity NSN 1 10-kilowatt generator (Interface Requirement) 1 61 15-01-275-5061 2 Modem Burner Unit (MBU) 7 73 10-0 1-452-8 137 v 3 MBU power converter 1 73 10-0 1-452-65 13 MIL-PRF-32026( GL) 3.2 Otwratin reauirements. 3.2.1 Transportation mode. When configured for transportation, the CK shall
21、be sheltered in an 8-foot by 8-foot by 20-foot IS0 container with forklift pockets (see 3.4.1 S). The CK shall meet all IS0 freight container requirements related to cargo containers, including a six-high stack, and shall meet Coast Guard requirements for safe containers. In transportation mode, the
22、 CK shall meet all transportability requirements (see 3.4.1). 3.2.2 Operational mode. When configured for food preparation, the CK shall have food preparation and serving areas protected from natural elements of the environment. All food preparation equipment, the electrical supply, the environmenta
23、l control system, and ail related controls and instniments shall be mounted inside the CK. Sheltered floorspace shall be sufficient to perform all necessary food preparation and serving tasks, with a minimum of 390 square feet (see 6.13). 3.2.3 Meal meDaration. The CK shall have a capability to prep
24、are and serve a minimum of 550 Army field menu meals (A-Ration, Heat and Serve Ration, or any combination, see 6.8) up to three times per day. The CK shall enable cooks to prepare a meai (A-Ration) in less than three hours. The CK shall have the capability to prepare and serve meals while mounted on
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF320261998CONTAINERIZEDKITCHEN 集装 厨房 PDF

链接地址:http://www.mydoc123.com/p-447095.html