1、I INCH-POUND 1 29 March 1999 SUPERSEDING 28 July 1993 MIL-PW-14516G MIL-H-145 16F PERFORMANCE SPECIFICATION HEATER, SPACE - BARRACKS, TENT, NON-POWERED, LIQUID FUEL This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1,l Scope. This specifica
2、tion covers the performance and acceptance requirements for a non- powered, liquid fuel burning, 60,000 BTU, radiant space heater for use in barracks, shelters, or tents. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification
3、; This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements docu
4、ments cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of the documents are those listed in the issue of the Depa
5、rtment of Defense Index of Specifications and Standards (DoDISS) cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2). Beneficial comments (recommendations, additions, deletions) an
6、d any pertinent data which may be of use in improving this document should be addressed to: Commander, U.S. Army Natick Research, Development, and Engineering Center, Natick, MA 01760-501 8 by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this documen
7、t, or by letter. AMSC NIA FSC 4520 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-PRF-LSIIG I 99Ob 2089474 348 e Military Symbol Ambient Temperature Range PF) F MIL-PW- 145 1 6G STANDARDS DEPARTMENT OF DEFENSE MIL-STD-8 1 O - Environmental Test
8、 Methods and Engineering Guidelines (Vnless otherwise indicated, copies of the above standard are available Tom the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 191 11-5094) 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subje
9、cted to a first article inspection in accordance with 4.1.1. 3.2 Conformance. A sample shall be subjected to conformance inspection in accordance with 4.1.2. 3.3 Operating requirements. The heaters shall satis the following user-oriented requirements. 3.3.1 Operation. The heater shall operate with a
10、ll specified fuels and under all specified conditions herein with no electrical power. 3.3.2 Ignition. The heaters shall not require any electrical power for ignition. Ignition shall be accomplished safely in ten minutes or less. 3.3.3 Monitoring. The heaters shall incorporate a means for viewing th
11、e entire combustion flame during operation. 3.3.4 Liquid fuel. The heaters shall be safely operated with all of the fuels listed in Table I. I DF-2 I above 25 OF I above 10 OF above -60 OF above -60 OF 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-
12、,-MIL-PRF-1451bG 9999Ob 2089475 284 II Ambient (O F) 40 MIL-PW- 145 16G Fuel output (low) Output (high) DF2 30,000 BTUHr 50,000 BTU/Hr 3.3.5 Fuel sup. The heaters shall be easily operated and set up by personnel attired in clothing appropriate for all intended user environments. The heater shall be
13、capable of being assembled for operation in 20 minutes or less, and disassembled and repacked for storage by two people in 15 minutes or less in any climatic category specified herein. 3.5 Environmental requirements. The heater shall operate as Specified under the following environmental conditions.
14、 3.5.1 Storage. The heater and accessories shall remain operable and show no signs of impairment due to storage at 155“ F for 4 hours daily. 3.5.2 Basic climate, The heater and accessories shall be operable in temperatures of +6O“ F to O“ F. Heat outputs shall be in accordance with Table II. 3.5.3 B
15、asic cold. The heater and accessories shall be in temperatures of -5 F to -25“ F. Heat outputs shall be in accordance with Table II. 3.5.4 High altitude. The heaters shall operate safely at a minimum of 85% rated capacity when operated at altitudes of 4,000 feet above sea level. 3.6 Interface requir
16、ements. The heater shall meet the following interface and interoperability requirements. 3 -6.1 Thermo-electric fan intefiace. The heater shall accommodate placement of the thermo- electric fan unit (see figure 1), so that it is positioned to direct air downward. An indented area shall be provided f
17、or placement of the base of the fan (see figure 2). The indented area shall provide sufficient heat transfer to the fan base to achieve a temperature of 500 “F - 600 “F at the fan module surface. If necessary, a spacer shall be permanently located on the indented area to position the fan base above
18、the heater surface to prevent over heat damage, while maintaining enough heat to achieve the required module temperature. 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-PRF-1451bG 99999Ob 2089479 92T E MIL-PRF-14516G FRONT .DW 8.5 inches high
19、 overall TOP VIEW 14.25 inch diameter BASE PLATE 0.5 inches high 5.25 inch diameter FIGURE 1. Thermo-Electric Fan Indented Location Spacer (approximate) on Heater Surface (section of standard steel pipe, 2 1/2“ nominal O.D. by .07“ wall thickness and .20 high, welded to heater surface) FIGURE 2. TEF
20、 interface location and typical spacer. 3.6.2 Fuel interface. During test of 4.5.2 the heater shall operate on DF2 conforming to A- A-52557. During test of 4.5.3, the heater shall operate on JP8 conforming to MIL-DTL-83133. During all operational tests herein, the fuel can used for the fuel supply s
21、hall conform to MIL-C- 53109. 3.6.3 Tent interface. The heaters shall be compatible for operation in the General Purpose Medium tent, MIL-T-1712. 7 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-L451bG IB 797770b 2087480 L4L II Fuel supply F
22、uel control OdOff switch MIL-PRF- 145 16G 3.3.5 4.3.5 X 3.3.6 4.3.6 X X 3.3.7 4.3.7 X X 4. VERTFICATION 4.1 Classification of insuections. The inspection requirements specified herein are classified as follows: a. First article inspection (see 4.1.1). b. Conformance inspection (see 4.1.2). 4.1.1 Fir
23、st article inspection. When a first article inspection is required (see 3.1 and 6.2), the heater shall undergo the tests and examinations outlined in table III. Sampling for first article inspection shall be as specified in the contract or purchase order. 4.1.2 Conformance inspection. Conformance in
24、spections shall be conducted according to the tests specified in table III. Sampling for conformance inspection shall be as specified in the contract or purchase order (see 3.3 and 6.2). 4.1.3 End item examination. Each heater shall be examined for the requirements specified in Table III. Any redesi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF14516G1999HEATERSPACEBARRACKSTENTNONPOWEREDLIQUIDFUEL 空间 加热器 液体燃料 驱动 营房 PDF

链接地址:http://www.mydoc123.com/p-447002.html