1、- MIL-P-70447 13 m 7979Ob 035qhO b m MIL-P-70449 (AR) 30 August 1983 MIL I TARY SPEC IF ICAT ION POWER MODULE ASSEMBLY FOR TEST SET, ELECTRONIC SYSTEM: M137 This specification is approved for use by the U.S. Army Armament, Munitions and Chemical Command and is available for use by all Departments an
2、d Agencies of the Department of Defense, 1. SCOPE 1.1 This specification covers requirements, quality assurance provisions, and preparation for delivery for Power Module Assembly: used on Test Set, Electronics System: M137. 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications, stan
3、dards and handbooks. Unless otherwise specified (see 6.2), the following specfications and standards of the issue listed in that issue of the Department of Defense Index of Specifications and Standards (DoDISS) specified in the solicitation, form a part of this specification to the extent specified
4、herein. SPECIFICATIONS MILITARY MIL-T-945 - Test Equipment for use with MIL-P-19834 - Plate Identification or Electronic Equipment: General Specif icatian. Instruction, Metal Foil, Adhesive Backed, General Specification for. Standard Quality Assurance Provision for. MIL-W- 6 3 15 O - Weapons and Sup
5、port Material, FSC 1310 Beneficial comments (recommendations, additions, deletions) and any pertinent ocument should be addressed and Development Center, Attn. e self-addressed Standardization 426) appearing at the end of this -. I THIS DOCUMENT CONTAINS 21 PAGES. Provided by IHSNot for ResaleNo rep
6、roduction or networking permitted without license from IHS-,-,-MIL-P-70447 13 U 777770b 035qb07 U MIL-P-70499 (AR) STANDARDS MILITARY MIL-STD-105 - Sampling Procedures and Tables for Inspection by Attributes. MIL-STD-704A - Aircraft Electric Power MIL-STD-810 - Environmental Test Methos. MIL-STD-118
7、8 - CommerSial Packaging of Supplies MIL-STD-1235 - Single and Multi-Level Characteristics. 1 and Equipment I Continuous Sampling Procedure and Tables for Inspecting by At t r i butes. 2.1.2 Other Government documents, drawinqs, and publications. The following other Government documents, drawings an
8、d publications form a part of this specification to the extent speclf ied herein: - DRAWINGS US ARMY ARMAMENT MUNITIONS AND CHEMICAL COMMAND PRODUCT 11834203 - Power Module Assembly. PACKAGING P11834203 - Power Module Assembly. (Copies of specifications, standards, handbooks, and publications requir
9、ed by manufacturers in connection with specific acquisition functions should be obtained from the contracting activity or as directed by the contracting officer.) 2.2 Order of precedence. In the event of a conflict between the text of this specification and the references cited herein, the text of t
10、his specification shall take precedence. 3. REQUIREMENTS 3.1 Materials. Materials shall be in accordance with the applicable drawings and specifications. 2 , r t Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-70447 13 7q997Ob 0354bLO 4 = MIL-P
11、-70499 (AR) 3.2 Components and assemblies. The components and assemblies shall comply with all requirements specified on Drawing 11834203 and associated drawings, MIL-W-63150, and with all requirements specified in applicable specifications and standards. 3.3 Electronic performance characteristics.
12、3.3.1 Performance. The Power Module Assembly shall have the performance characteristics specified herein. 3.3.1.1 Electrical. The Power Module Assembly shall operate from a nominal 28 volts DC supply and provide outputs of 28 volts DC and 115 volts AC at 400 Hertz. 3.3.1.1.1 Input voltaqe. The Power
13、 Module Assembly shall operate with 24 through 30 volts DC applied to Terminals A (Positive) and B (Return) of plug P1. Terminal C shall be connected to ground. 3.3.1.1.2 Input current. The input current through circuit breaker CB1 to the power supply module shall not exceed 10 amps. 3.3.1.1.3 Input
14、 transient protection. The unit shall be able to withstand a transient surge voltage in accordance with MIL-STD- 704A, Figure 9, Limit 1 (80VDC for 0.1 seconds). 3.3.1.1.4 Output voltages. The voltage across Terminals A and B of Receptacle J1 shall be equal to the input voltage within 0.5 volts. The
15、 voltage across Terminals A and B of Receptacle J2 shall be adjustable within the range 108 to 122 VAC. The ouput voltage shall be adjusted by turning the screw on the top of the power supply module case. 3.3.1.1.5 Output currents. - The DC output current shall be protected by a 10 amp curcuit break
16、er, The AC output shall be capable of supplying up to 1.044 amps continuously at rated output voltage. 3.3.1.1.6 Output frequency. The AC output shall have the form of a sine wave of 400 Hertz + 1 percent. There shall be a maximum of 4 percent harmonic distortion into a resistive load. 4 3.3.1.1.7 S
17、hort circuit protection. The power supply shall be protected against a short circuit condition on the AC output of any duration. The unit must be recycled to restore output. 3.3.1.1.8 Load transient recovery time. The AC output voltage shall return to regulation limits within 5 cycles for a change f
18、rom no load to full load. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-70499 (AR) 3.4 Desiqn and construction. 3.4.1 Production drawings. The Power Module Assembly shall be fabricated and assembled in accordance with the associated drawing
19、s, parts lists and other documents listed on Drawing 11834203. 3.5 Environmental requirements. 3.5.1 Operating temperature. The unit shall be operable in the range of -65OF (-54OC) to +212OF (+lOOC). 3.5.2 Environments. Shall meet the environmental reouirements of MIL-STD-810 for altitude, vibration
20、, shock, acceleration, sand, dust, humidity, salt-spray, fungus, and explosive atmosphere. technical provisions for first article inspection. Requirements for the submission of first article samples by the contractor shall be as specified in the contract. 3.7 Workmanship. Finished items and parts sh
21、all be fabricated in a thorough, workmanlike manner, and all manufacturing, processing, and assembly operations shall be correctly performed. The parts shall not exhibit faulty material and processing such as seams, laps, laminations, cracks, visible steps, sharp edges, nicks, scratches, burrs, defo
22、rmations, unblended radii, chips, dents, rust, dirt, grease and oil (except where specifically required), corrosion products, flux, other foreign matter, and missing operations which may affect serviceability, operation, or safety. The cleaning agents shall not be injurious to any part or assembly.
23、Exterior surface coatings shall be continuous; however, a few light scratches not exposing base material may be permitted. and stamping shall be neat and sharply defined. shall be dry. minimum length or depth as required on the applicable drawing. Cable assemblies and wires shall be neatly dressed a
24、nd tied in such a manner as to prevent pinching or chafing the wire insulation. Ends of wires shall be free from burrs, sharp edges or points. Castings shall be clean, sound, and free from blowholes, porosity and inclusion. Welds shall be reasonably smooth and free of craters and cracks. They shall
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILP704491983POWERMODULEASSEMBLYFORTESTSETELECTRONICSYSTEMM137M137 电子 系统 测试 备用 电源模块 组件 PDF

链接地址:http://www.mydoc123.com/p-446871.html