1、MIL-P-63234 (AR) AMENDNENT 3 12 JULY 1989 SUPERSEDING . AMENDMENT 2 8 June 1983 MI LI TARY SPEC IF I CATION PXOJECTILE, GUIDED, .155MM, XM712 ROLL RATE SENSOR FOR This amendment forms a part of Military Specification MIL-P-63234(AR), dated 31 August 1979, and is approved for use within the US Army A
2、rmament Munitions and Chemical Command and is available for use by all Departments and Agencies of the Department of Defense. PAGE 1 Title: Add “Bl712“ after the designation “XM712“. Make this addition wherever “XM712“ appears in the entire specif ica- tion. PAGE 3 3.2.1.4: Delete entire paragraph.
3、i PAGE 4 3.2.2.2: Delete entire paragraph and substitute the following: “3.2.2.2 Vibration.- The RRS shall be capable of with- standing a random vibration environment of 7.6 g rms, 0.04G2/Hz power spectral density, 20 to 2000 Hz. During , vihration the rate signal shall not exceed 4 SVDC and shall.
4、not exhibit a signal step change greater than 2 1 VDC. g RMS at 20 to 2000 Hz and shall meet the performance during vibration of 3.2.1.3 for required data input.“ The RRS shall operate-during random vibration of 2.4 3.2.2.3: Delete entire paragraph and substitute the following: “3.2.2.3 Relative hum
5、idity.- The RRS shall withstand relative humidity exposures of greater than 90 percent at + 68OF to + 149OF“ AMSC N/A 1 of 7 FSC 1320 _DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without licens
6、e from IHS-,-,-* 4.4.1 D t following: 1 MIL-P-b3234 MIL-P-63234 (AR) AMENDMENT 3 PAGE 6 last sentence in its entirety a i sub titue the size shall be no greater than one months production and RRS Assemblies in the lot shall be from one manufacturer and have the same interfix number. There may be up
7、to three consecutive subassembly configurations (denoted by the manufacturers RRS modification number on the identification plates) within each Lot of RRS Assemblies, provided that the LAT sample contains a minimum of three RRS Assemblies from each of the subassembly configurations.“ 4.4.2.2: Add th
8、e following words to end of paragraph: “Rejected lots shall be dispositioned in accordance with the applicable requirements of MIL-STD-105.“ PAGE 7 4.5.2.5: Delete entire paragraph. PAGE 8 4.5.3.3: Delete entire paragraph and substitute the following: “4.5.3.3 Vibration test.- The vibration test sha
9、ll he performed intwo phases, gross operating vibration and performance vibration. Total operating time shall be seven minutes, five minutes for gross operating and two minutes for performance. The input vibration amplitude shall be reduced to zero between the two portions. The RRS shall have all in
10、put power removed for a minimum of 10 minutes prior to initiation of the Performance Vibration Test. Acceptance criteria shall be as specified in paragraph 3.2.2.2. “4.5.3.3.1 Gross operating vibration.- The RRS shall be tested while operating during vibration per MIL-STD-810CI Method 5142, Procedur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILP6323431989PROJECTILEGUIDED155MMXM712M712ROLLRATESENSORFORXM712 M712 155 MM 制导 炮弹 用滚转 传感器 PDF

链接地址:http://www.mydoc123.com/p-446754.html