1、I NCH-POUNDMIL-P-00223C (AR)AMENDMENT 22 October 1998SUPERSEDINGAMENDMENT 110 June 1997MILITARY SPECIFICATIONPOWDER, BLACKThis Amendment forms a part of Military Specification MIL-P-00223C (AR) dated 5February 1993, and is approved for use by the U.S. Army Armament Research,Development and Engineeri
2、ng Center and is available for use by all Departmentsand Agencies of the Department of Defense.PAGE 2* 2.1.1 Delete the following documents:“RR-S-366MIL-STD-129MIL-STD-1218MIL-STD-1235”and substitute with the following:“MIL-STD-1916 DOD Preferred Methods for Acceptance of Product”PAGE 3* 2.1.2, Add
3、“12982865 Minimum Marking Instructions for Ammunition and ExplosivesContainers” to the US Army ARDEC drawing list.PAGE 53.3.3 Applicable to class 3 only: Add “(See 6.13)” at the end of 3.3.3.AMSC N/A 1 of 6 FSC 1376DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.Prov
4、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-00223C (AR)AMENDMENT 23.5 Delete 3.5 and substitute with the following:“3.5 Specific gravity.3.5.1 Specific gravity determined by mercury pycnometer. The specific gravity ofblack powder shall not exce
5、ed the limits of 1.72 minimum and 1.80 maximum for glazedpowder, 1.65 minimum and 1.81 maximum for unglazed class 7 powder and 1.69minimum and 1.76 maximum for unglazed class 8 and 9 powder when determined asspecified in 4.5.6.1, 4.5.6.2 or 4.5.6.3.3.5.2 Specific gravity determined helium gas pycnom
6、eter. The specific gravity ofblack powder shall not exceed the limits of 1.890 minimum and 2.012 maximum forclasses 1 to 6 glazed powder and 1.955 minimum and 1.997 maximum for unglazedclass 7 powder when determined as specified in 4.5.6.4.”3.7 Granulation, Table II:Class 7: Delete “5%” maximum, and
7、 substitute “7%” maximum allowable weightpercents of class 7 black powder passing through U.S. Standard Sieve #100 in Table II.Class 8: Delete “3%” maximum, and substitute “5%” maximum allowable weightpercents of class 8 black powder retained on U.S. Standard Sieve #100 in Table II.PAGE 144.4.2.4 Te
8、st sampling, second sentence:Delete: “Batches are units of product that shall be selected for inspection IAW theprocedure in MIL-STD-1235, CSP-1 plan, Code letter D, f=1/5, i=11.”Substitute: “Batches are unit of product that shall be selected for inspection inaccordance with MIL-STD-1916 except that
9、 in lieu of Table IV (MIL-STD-1916) thefollowing continuous sampling plan shall be used: i=11, f=1/5, and that there shall be noreduced or tightened inspection level.”4.4.2.5 Sample preparation for analysis, first sentence: Delete “RR-S-366 or” andsubstitute“ shall comply with ASTM E11”PAGE 15* 4.5
10、Method of Inspection, second sentence: Delete “in accordance with MIL-STD-1218” andsubstitute “ all chemicals shall be Reagent Grade or ACS Grade.”2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-00223C (AR)AMENDMENT 24.5.2.1 Alternate method f
11、or moisture: Rename 4.5.2.1, “Alternate method A formoisture”.4.5.2.2 Alternate method for moisture: Rename 4.5.2.2, “Alternate method B formoisture”.4.5.2 Add 4.5.2.3 as follows:“4.5.2.3 Alternate method C for moisture. An Arizona Instrument CorporationsComputrac MAX-50 moisture analyzer or its equ
12、ivalent shall be used for this method.The Computrac MAX 50 moisture analyzer is a microprocessor controlled instrumentwith programmable heating temperatures from 25 deg. C to 225 deg. C whichincorporates a closed loop heat sensing system that will maintain temperature controlwithin plus or minus 1 d
13、eg. C. Self diagnostics assure that a Fail Safe condition will exist,shall a default occur. The analyzer heats the sample within an enclosed test chamber withthe use of a nichrome heating element. Through a predictive feature, the analyzerautomatically terminates the test at an accurate end point. A
14、 built-in electronic forcebalance automatically weighs the sample as it is being added then displays the finalmoisture content as either percent moisture or percent solid at test completion.Resolution of the MAX-50 is 0.01% and is designed to accurately detect moisture levelsdown to 0.10% (10 gm cap
15、acity unit) and 0.04% (20 gm capacity unit).The unit (Computrac MAX-50 or its equivalent) shall be turned on and allowed towarm up for about 20 minutes. Set the unit to display %MOIST. The test temperatureshall be set at 85 deg. C. Open the test chamber lid and place a clean sample pan onto thetray
16、support. With the test chamber lid closed, push the START key. When theLOAD light on the display illuminates, open the test chamber lid, and evenly depositenough black powder onto the sample pan until the display reads between 70 and 90percent at which time the analyzer will emit a short beep to ale
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILP00223C21998POWDERBLACK 火药 PDF