1、MIL-M-63333(AR)15 February 1980MILITARY SPECIFICATIONMOUNT PERISCOPE ASSEMBLY: 11834833This specification is approved for use by the U.S. Army Armament Researchand Development Command and is available for use by all Departments andAgencies of the Department of Defense.1. S COPE1.1 This specification
2、 covers a periscope mount which is used withperiscopes: XM44E1 and XM44E2 (See 6.1).2. APPLICABLE DOCUMENTS2.1 The following documents, of the issue in effect on date of invitationfor bids or request for proposal, form a part of this specification to theextent specified herein.SPECIFICATIONSMilitary
3、MIL-F-13926MIL-P-14232MIL-I-45607STANDARDSMilitaryMIL-STD-105MIL-STD-109MIL-STD-810Fire Control Materiel; General SpecificationGoverning the Manufacture and Inspection of “Parts, Equipment and Tools for Army Materiel;Packaging and Packing ofInspection Equipment, Acquisition, Disposi-tion and Mainten
4、ance ofSampling Procedure and Tables for Inspectionby AttributesQuality Assurance Terms and DefinitionsEnvironmental Test MethodsBeneficial comments (recommendations, additions, deletions) and any pertinent datawhich may be of use in improving this document should be addressed to: Commander,US Army
5、Armament Research and Development Command, Attn. DRDAR-QA, Dover,New Jersey 07801 by using the self-addressed Standardization Document ImprovementProposal (DD Form 1426) appearing at the end of this document or by letter.FSC 1240Provided by IHSNot for ResaleNo reproduction or networking permitted wi
6、thout license from IHS-,-,-MIL-M-63333(AR)DRAWINGSU.S. Army Armament Research and Development Command (ARRADCOM)F8565556F11834833F11834841F105422O4F105582O3FI1738174FI1738175FI1738176F11738177F11738180F11738181F11738182F11738183Pressure Tester - Two StationMount, Periscope Assy: 11834833Body Assembl
7、y, Tank Periscope: 11834841Head Assembly, Tank Periscope: 10542204Head Assembly, Tank Periscope: 10558203Gage - Interchangeability - Body MaximumGage - Interchangeability - Body MinimumGage - Interchangeability - Head MinimumGage - Interchangeability - Head MaximumFixture - Pressure Testing - Head M
8、aximumFixture - Pressure Testing - Head MinimumFixture - Pressure Testing - Body MaximumFixture - Pressure Testing - Body MinimumPACKAGING DATA SHEETPS11834833 Packaging of Mount, Periscope: 11834833(Copies of specifications, standards, drawings and packaging data sheetsrequired by suppliers in conn
9、ection with specific procurement functions shouldbe obtained from the procuring activity or as directed by the contractingofficer.)3. REQUIREMENTS3.1 Fabrication. The periscope mount, hereinafter referred to as “mount”shall be manufactured in accordance with Drawing F11834833 and drawingspertaining
10、thereto.3.2 General specification. The contractor shall be responsible foradherence to, and compliance with, the requirements of MIL-F-13926 specifiedbelow:a. Order of precedenceb. Dimensions and tolerancesc. Inorganic protective surface finishesd. Part identification and markinge. Workmanshipf, Sol
11、dering electrical connections3.3 Environmental.2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-M-63333(AR)3. 3.1 Storage temperatures. The mount shall show no evidence of physicalfailure such as casting failure, adhesive failure, or deterioratio
12、n of Gasket10513302 due to storage at temperatures ranging from -80 to +160Fahrenheit (F). Subsequent to meeting this requirement, the mount shall becapable of meeting the requirements of 3.8.1.3.3.2 Extreme operating temperatures. The mount shall meet theapplicable requirements of 3.8.1 while expos
13、ed to and thermally stabilized attemperatures of -650 and +150F.3.3.3 Standard temperature. unless otherwise specified herein, the mountshall meet the following requirements while exposed to a temperature between+60 and +90F.3.4 Orientation. The requirements of 3.6, 3.7 and 3.8 shall be met withDatu
14、m Plane “A” in a horizontal plane within 2.0 degrees of arc and the shieldassembly and Mount Assembly 11834835 positioned as shown on DrawingF11834833. Unless otherwise specified, the shield shall be in the raisedposition.3.5 Vibration. The mount shall show no evidence of physical failure dueto bein
15、g vibrated successively along 3 mutually perpendicular axes. Vibrationshall be a simple harmonic motion, the frequency varying either linearly orlogarithmically from 5 to 55 to 5 cycles per second in 5 minute cycles for atotal of 15 minutes along each of the axes. The amplitude of vibration shallbe
16、maintained constant at 1/64 inch (1/32 inch total excursion). Followingthe vibration test, the mount shall meet the requirements of 3.7.3, and shallthen meet all of the following requirements.3.6 Sealing. The mount shall be capable of meeting this requirementwhile exposed to prolonged rainfall with
17、the shield in the raised position.Gasket 10513302 shall be capable of preventing water penetration below thecontact surfaces when the periscope head assembly is positioned in the mount.3.7 Periscope holding features.3.7.1 Insertion and removal. The mount shall permit insertion andremoval of the head
18、 assembly and body assembly of the periscope withoutrestriction.3.7.2 Periscope mounting repeatability. An original line of sight,through the periscope body assembly, shall not deviate more than 0.10 mil dueto repeated mounting of the body assembly to the mount.3.7.3 Rigidity (line of sight retentio
19、n). The mount shall be capable ofmaintaining a previously established line of sight, through the periscope bodyassembly, within 0.10 mil subsequent to vibration (see 3.5).3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-M-63333(AR)3.8 Operability
20、. The requirements of 3.8.1 shall be met at thetemperatures specified in 3.3.2 and 3.3.3.3.8.1 Controls.3.8.1.1 Periscope locking lever. Lever Assembly 8589900, shown onDrawing F11834835, shall be manually operable through the range required tosecure and permit removal of the periscope body assembly
21、.3.8.1.2 Shield actuating handle. Handle 10542148 shall be manuallyoperable through the range required to raise and liner the shield to the fullyopen to the fully closed position.3.8.1.3 Handle locking latch. When Latch 10542138 is released while theshield is being raised, the handle shall lock the
22、shield in the fully openposition. When the latch is released while the shield is being lowered, thehandle shall lock the shield in the fully closed position.3.9 Circuitry. The circuitry of the mount shall have electricalcontinuity between its respective terminations and show no continuity betweenter
23、minations and mount.3.10 interchangeability.3.10.1 Interchangeability - mechanical. The mount shall be capable ofaccepting Head Assemblies 10542204 and 10558203 and Body Assemblies 11834841-2and 11834841-1.3.10.2 Interchangeability - pressure retention. With the head and bodyassemblies mated to the
24、mount, the mount shall withstand an internal pressureof 5 + 0.10 pounds per square inch gage (psig) for a minimum of 2 hourswithout loss of pressure in excess of 0.2 pounds (psig).4. QUALITY ASSURANCE PROVISIONS4.1 Responsibility for inspection. Unless otherwise specified in thecontract or purchase
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILM633331980MOUNTPERISCOPEASSEMBLY11834833 潜望镜 装配 11834833 PDF

链接地址:http://www.mydoc123.com/p-445917.html