1、MIL-fl-45664E 12 7779906 O308365 7 m MIL-M-4 5 6643 (MU) 31 January 1974 SUPERSEDING MIL-M-45664D (MU) 8 June 1970 MILITARY SPECIFICATION MOUNT, PERISCOPE: Ml18 AND Mi.18E1 1. SCOPE 1.1 This specification covers instruments known as Mount,Periscope: Mi18 and Mont, Periscope: Ml18E1 (see 6.1). 2. APP
2、LICABLE DOCUMENTS 2.1 The following documents, of the issue in effect on date of invi- tation for bids or request for proposal, form a part of this specification to the extent specified herein. SPECIFICATIONS Militar y MIL-F-13926 MLL-P-14232 MIL-1-45607 STANDARDS Military MIL-STD-105 MIL-STD-109 6.
3、 DRAWINGS Frankford Arsenal F8619450 A8 644448 F10554660 F10554661 F10554663 Fire Control Materiel: General Specifi- cation Governing the Manufacture and Inspection Of Parts, Equipment and Tools for Army Materiel; Packaging and Packing of Inspection Equipment, Supply and Maint- enance of Sampling Pr
4、ocedures and Tables for In- Quality Assurance Terms and Definitions spection by Attributes Mount, Periscope: Ml18 Push-Pull Gage Holding Fixture Set-up Final Test Fixture for Mount, Test Standard for Mount Periscope: Ml18 Periscope: Mi.18 FSC 1240 I- A Provided by IHSNot for ResaleNo reproduction or
5、 networking permitted without license from IHS-,-,-MIL-M-4Sbb4E 12 m 7777906 03083bb 7 F11732148 F11732149 E11727490 PACKAGING DATA SHEET PS8619450 PS11727490 Gage, Interchangeability, Maximum Gage, Interchangeability, Minimum Mount, Periscope: Mi18E1 Packaging of Mount, Periscope: Ml18 Packaging of
6、 Mount, Periscope: M118E1 (Copies of specifications, standards, drawings, and packaging data sheets required by suppliers in connection with specific procurement functions should be obtained from the procuring activity or as directed by the con- tracting officer.) 3. REQUIREMENTS 3.1 Fabrication.- T
7、he mount shall be manufactured in accordance with Drawing F8619450 (Ml18), or E11727490 (Ml18El), and drawings pertaining thereto. 3.2 General specification.- The contractor shall be responsible for adherence tos and compliance with, the following requirements of MIL-F- 13926: (a) Order of precedenc
8、e. (b) Dimensions and tolerances. (c) Inorganic protective surface finishes. (d) Part identification and marking. (e) Uorkmanship . 3.2.1 Interchangeability.- The mount shall be capable of permitting insertion of the gages specified in 4.6.7. shall be capable of being firmly.secured and subsequently
9、 removed. After insertion, the gages 3.3 Environmental. 3.3.1 Operating temperatures.- The mount shall meet the applicable requirements of 3.5.1 to 3.5.4.2 inclusive while exposed to and thermally stabilized at ambient temperatures of -40 and +150F. z .* 3.3.2 Vibration,- The mount shall be vibrated
10、 at a constant frequency of 30 cycles per second with an amplitude of 1/16 inch (1/8 inch maximum excursion) for a period of 5 t1/4 minutes. Subsequent to vibration, there shall be no evidence of physical failure and the mount shall meet the fall- owing requirements of this specification (see 3.5-4.
11、2). 3.4 Orientation,- The locating surface of the mounting flange of the Gages referenced in 3.2.1 mount shall be secured in a horizontal plane and the headrest assemblies shall be in their uppermost vertical position. shall be utilized to determine compliance with the requirements of 3.5.1 and 3-5.
12、2. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-M-45 6 643 (MU) 3.5 Perf ormance 3.5.1 Release grip.- With the gages in 3.2.1 inserted into the mount, the release grip shall automatically latch the gages in the fully inserted position, A dir
13、ect pull of not more than 15 pounds on the release grip shall actuate the grip to its full disengaged position. of the grip shall allow removal of the gages from the mount without re- strictions. Full disengagement 3.5.2 Holding features.- When Lever 8619482 is pushed to its fullest forward position
14、 and locked by releasing the plunger, the gages (see 3.2.1) shall be secured in the mount. pound pressure applied horizontally to the front and rear of each gage at a point 7.5 inches below the center of the plugs (Part No. 8298440), the gage shall be within .O005 inch of its original location when
15、measured horizontally at a point 7.5 inches below the center of the plugs. This requirement shall be met following the release of each of the pressures applied. Subsequent to the application of a ten 3.5.3 Shield assembly.- With the plunger depressed (disengaged), maxi- mure operation of the handle
16、shall operate the shield through full operation (open for viewing and closed for protection). and when the shield is fully closed, the plunger shall engage and lock the handle when the plunger is released. When the shield is fully open 3.5.4 Headrest. 3.5.4,l Headrest horizontal travel.- Each Knob B
17、8619466 (M118) or Screw B10516599 (Mi18E1) shall be loosened and each headrest assembly shall be adjustable through maximum movement permitted by the elongated slot in the assembly without restriction or force. 3.5.4.2 Retention.- The torsional load applied to each Screw 8619463 (see applicable Draw
18、ing F8619450or E11727490) shall be such that the head- rests shall not change position when subjected to the vibration specified in 3.3.2 and shall be operable at the temperature specified in 3.3.1, 4. QUALITY ASSURANCE PROVISIONS z 4.1 Responsibility for inspection.- Unless otherwise specified in t
19、he contract or purchase order, the supplier is responsible for the performance of all inspection requiremats as specified herein, specified, the supplier may utilize his own facilities or any other faci- lities suitable for the performance of the inspection requirements speci- fied herein, unless di
20、sapproved by the Government. The Government reserves the right to perform acy of the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. Except as otherwise 3 . . Provided by IHSNot for ResaleNo re
21、production or networking permitted without license from IHS-,-,-4.1.1 General provisions.- The component and subassembly inspection requirements of MIL-F-13926 form a part of the quality assurance provis- ions of this specification. Definitions of inspection terms shall be as listed in MIL-STD-109,
22、4.2 First article (initial production) approval.- The requirement for first article approval and the responsibility (Government or contractor) for first article testing shall be as specified in the contract. le for first article approval tests shall consist of three mounts plus three each of all ite
23、ms covered by SQAP. in the same manner, using the same materials, equipment, processes, and procedures as used in regular production. All parts and materials, in- cluding packaging and packing, shall be obtained from the same source of supply as used in regular production. The samp- The sample shall
24、 be manufactured 4.2.1 Government testing.- When the Government is responsible for con- ducting first article approval tests, the contractor, prior to submitting the sample to the Government, shall inspect the sample to insure that it conforms to all the requirements of the contract and submit a rec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILM45664E1974MOUNTPERISCOPEM118ANDM118E1PDF

链接地址:http://www.mydoc123.com/p-445736.html