1、4-01-27 MIL-L-48768 (PA) i9 June i975 MILITARY SPECIFICATION LITHIUM RESERVE BATTERY ELECTROLYTE This specification is approved for use by all Departments and Agencies of the. Department of Defense. 1. SCOPE 1.1 This specification covers a type of electrolyte for use in lithium reserve type batterie
2、s (see 6.3). 2. APPLICABLE DOCUMENTS 2.1. The following documents of the issue in effect on date of invitation for bfds or request for proposal form a part of this speci- fication to the extent specified herein. SPECIFICATIONS MILITARY MIL-A-48078 - Ammunition, Standard Quality Assurance MIL-L-48765
3、 - Lithium Hexafluoroarsenate MIL-L-48766 - Lithium Tetrafluoroborate MIL-M-48767 - Methyl Formate Provisions, General Specification For STANDARDS MILITARY MIL-STD-129 - Marking for Shipping and Storage (Copies of specifications, standards, drawings, and publications required by suppliers in connect
4、ion with specific procurement function should be obtained from the procuring activity or as directed by the contractipg officer). FSC: 6810 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-. . , , MIL-L-q7b b W 7977706 0323250 W MIL-L-48768 (PA) 2.2 O
5、ther publications.-The following documents form a part of this specification to the extent specified herein. Unless otherwise indicated, the issue in effect on date of invitation for bids or request for proposal shall apply. AMERICAN SOCIETY FOR TESTING AND MATERIALS ASTM-E70 - pH of Aqueous Solutio
6、ns with the Glass Electrode ASTM-E203 - Water Using Karl Fischer Reagent ASTM-E260 - General Gas Chromatography Procedures ASTM-E300 - Sampling Industrial Chemicals ASTM-Dq45 - Kinematic Viscosity of Transparent and Opaque Liquids (Application for copies should be addressed to the American Society f
7、or Testing and Materials, 1916 Race Street, Philadelphia, Penn- sylvania 19103). 3. REQUIREMENTS 3.1 Materials.-Materials used in the manufacture of the electrolyte shall conform with the specifications given below and shall be mixed in the proportions shown: Materials App 1 i cab 1 e Proportions By
8、 Specification Weigh (see 6.3) Lithium Hexaflu- Lithium Tetra- oroarsenate MIL-L-48765 f luoroborate MIL-L-48766 MIL-L- 4 8 7 6 7 Methyl Formate 18 1.72 40, p9 3.2 Properties.-The electrolyte shall conform to the following 2 Provided by IHSNot for ResaleNo reproduction or networking permitted withou
9、t license from IHS-,-,-MIL-L-48768 68 m 7777706 OL2125L T m MIL-L-48768 (PA) properties when tested in accordance with applicable paragraphs (see 6.5): Property Color Insoluble Matter Specific Gravity d 25.0 5 0.loC 25.0 5 0.loC centistokes Water,ppm,max Methanol,ppm,max Formic Acid,ppm,max Dimethyl
10、 Ether,ppm,max Total Impurities ,ppm, viscosity Purity max Refractive Index 25 + 2OC pH Q 25 + 2OC Diffussion Current, microamps Specific Conductance 25 5 0.loC Requirement Clear l) through a clean, tared glass medium porosity .filtering crucible. Use a small amount of methyl formate to aid in the t
11、ransfer. Dry the crucible and contents in an oven maintained at 85 + 5OC for 1 hour, cool in a desiccator and weigh. Calculate the Insoluble Matter as compared to the total LiAsF6 and LiBF4 according to the following equation: % Insoluble Matter = Wt Insoluble in Grams X 100 Volume Sample in Liters
12、x 429.22 4.4.3.3 Specific Gravity.-The specific gravity shall be determined .4.4.3.3.1 Equipment: by the following procedure: a. Two calibrated pycnometers (see Figure i) fitted with Thomas red rubber stoppers - cat. No. 1781-E93. b. 25cc syringe fitted with a 12 inch needle. C. Controlled temperatu
13、re chamber: 25OC - + 0.loC d. 20 cc of solution to be tested. 4.4.3.3.2 Procedure.-Weigh the dried pycnometers (with stopper). Fill each pycnometer until the solution is at least half way up the neck employing the 25 cc syringe and 12 inch needle. The needle 5 Provided by IHSNot for ResaleNo reprodu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILL487681975LITHIUMRESERVEBATTERYELECTROLYTE 后备 锂电池 电解液 PDF

链接地址:http://www.mydoc123.com/p-445606.html