《ARMY MIL-K-71129 (4)-1996 KIT REFURBISHMENT FOR CARTRIDGE 81MM PRACTICE SHORT RANGE M880 LOADING ASSEMBLING AND PACKING《M880式81 mm近程教练弹用翻新套件及其装药 组装和包装》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-K-71129 (4)-1996 KIT REFURBISHMENT FOR CARTRIDGE 81MM PRACTICE SHORT RANGE M880 LOADING ASSEMBLING AND PACKING《M880式81 mm近程教练弹用翻新套件及其装药 组装和包装》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-K-71129 (4) W 999990b 2028308 530 m INCH-POND MIL-K-71129 (AR) AMENDMENT 4 17 December 1996 SUPERSEDING AMENDMENT 3 23 April 1996 MILITARY SPECIFICATION KIT, REFURBISHMENT, FOR CARTRIDGE, 81MM PRACTICE, SHORT RANGE, M880 LOADING, ASSEMBLING AND PACKING This amendment forms a part of MIL-K-71129
2、(AR), dated 26 May 1992, and is approved for use by the U.S. Army Armaments Research, Development and Engineering Center, and is available for use by all Departments and Agencies of the Department of Defense. PAGE 3 3.3 : Delete: “propelling charge“, and substitute: “ignition cartridge“. Delete 3.6.
3、1 in its entirety and substitute: “3.6.1 Misfires. The cartridges shall not fail to fire from the weapon when they are initially dropped into it.“ * Delete 3.6.2 in its entirety and substitute: “3.6.2 Short rounds. Cartridges having a horizontal range less than 80 percent of the average horizontal r
4、ange (calculated without the short rounds) will be classified as a short round. I Delete 3.6.4 in its entirety and substitute: “3.6.4 Ranse and deflection Precision. The cartridge shall have a horizontal range probable error (PEr) less than 15 meters, for all zones when calculated to the nearest one
5、 tenth (0.1) meter. The deflection probable error (PEd) shall be less than 15 meters for all zones when calculated to the nearest one tenth (0.1) meter.“ 1 of 9 AMSC N/A FSC 1315 DISTRIBUTION STATPHENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reprodu
6、ction or networking permitted without license from IHS-,-,-MIL-K-71129 (AR) AMENDMENT 4 J PAGE 4 3.6.6: Add: “unobstructed“, before the word “flight“. 3.6.9 Add the following: 3.6.9 Dud pluu function. “3.6.9.1 Functioned round. All dud plug heads (regardless of stems) shall blow out of the projectil
7、e body upon fuze function.“ “3.6.9.2 Inert round. No dud plug head (regardless of stems) shall exit the projectile body during ballistic flight or upon impact.“ 3.9 Add the following: “3.9 Dud pluqs.“ “3.9.1 Confiuuration. Three dud plugs properly inserted into the projectile body ground test. I sha
8、ll be present and for the proving “3.9.2 Dud plu4 push in - push out force. No dud plug shall push into the required test plate using a force greater than 40.0 pounds and shall not be capable of being pushed out of the required test plate using a force of less than 25.0 pounds at a temperature of 70
9、 degrees F 2 -3 degrees F when tested as specified in 4.5.4.“ PAGE 6 * 4.3.3(b), Add after first sentence: “Graze impact duds shall not be counted for score. These shall be recorded for information only and shall be x-rayed to document that the fuze was armed. Side impact duds shall be recorded for
10、information only and x-rayed to document that the fuze was armed. If more than four side impacts occur, the first article sample represented by the sample shall be referred to the technical agency for disposition. In either of the above cases, if the x-ray reveals that the fuze did not arm, the fuze
11、 shall be considered to be a dud.“ * Delete *c“ in its entirety and substitute: “c. One or more short rounds occur at +110 degrees F or +70 degrees F. Two or more short rounds occur at O degrees F.“ 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-M
12、IL-K-71129 (q) 9999906 2028110 199 MIL-K-71129 (AR) AMENDMENT 4 PAGE 6 (cont) Delete “g“ and “h“ in their entirety and substitute: “g. If the weapon is damaged by abnormal wear of the interior or of the firing pin, or caused by excessive pressure.“ “h. Two or more improper impact signatures occur.“
13、Add the following: Il i . All three dud plug heads (regardless of stems) are missing from the projectile body in the inert fuze ballistic test. “j. Two or more dud plug heads (regardless of stems) fail to exit projectile bodies (accumulatively, i.e., two remaining in a single projectile or one each
14、remaining in two projectiles) in the live fuze ballistic tests (except in the case of a particular round that was an actual dud, in which case paragraph i .It above applies) .It PAGE 7 Table I: Proving ground test line, under Conformance Criteria: Delete: 1721, and substitute: “96“. Add the followin
15、g: “Dud Plug . . . (dwg. 12961001) Examination for defects . 30 . 3.1 . 4.4.2.11 Push in - push out test . 30 . 3.9.2 . 4.5.4ll. PAGE 9 4.4.1: Delete the word “interfix“ from the text from lines a., b., c., and d. Add the following: “e. Dud plugs from one inspection lot that comply with 3.9 -2. 3 Pr
16、ovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PAGE 11 4.4.2.1, Major 105: Change call out: from: “Length of large outside diameter section“, to: “Length between large outside diameter aft face to firing pin point“. PAGE 15 4.4.2.5: Delete Special A i
17、n its entirety. Critical: Add the following: 1 Fuze striker in armed position . 100% . 3.1 . Visual“. PAGE 16 4.4.2.6: Delete Major 103 in its entirety. PAGE 20 4.4.2.10: Delete Specials A, B, C, D, E, F and G in their entirety and add the following: 4 Provided by IHSNot for ResaleNo reproduction or
18、 networking permitted without license from IHS-,-,-MIL-K-7Li29 (4) 9999906 2028ii2 Tbi = MIL-K-71129 (AR) AMENDMENT 4 r bRAWING NUMER 12961001 PARAGRAPH ITLE 1NEXT HIGHER ASSEIIBLY “4.4.2.11 Dud Plug SHEET 1 OF CONFORMANCE REPUIREMENT INSPECTION METHOD CIASSIFICATION EXAMINATION OR TEST CRITERIA PAR
19、AGRAPH REF ER EN C E Critical None defined PAGE 21 Maior 101 Push in - push out test 30 3.9.2 Test/4.5.4 L.l.LlIVL I 201 poor workmanship I t hn:, I I I I I I I 30 3.6 Visual“ 4.4.3.1: Delete in its entirety and substitute: “4 4.3.1 Provins mound test. 4.4.3.1.1, Add: “The refurbished cartridges sha
20、ll be observed for the following characteristics: a. b. d. e. f. 9. h. i. C. j. Misfires, major defect (see 3.6.1) Duds, major defect (see 3.6.5) Short rounds, major defect (see 3.6.2) Premature burst, critical defect (see 3.6.6) Metal parts separation, major defect (see 3.6.3) Precision, major defe
21、ct (see 3.6.4) Weapon damage, major defect (see 3.6.7) Improper impact signature, major defect (see 3.6.8) All dud plug heads out of any one projectile in the inert fuze ballistic test, Critical defect (see 3.6.9.2) Two or more dud plug heads remain in the live fuze ballistic test, Major defect (see
22、 3.6.9.1)“. 4.4.3.1.2, Add: “i. All three dud plug heads (regardless of stems) are missing from the projectile body in the inert fuze ballistic test. j. Two or more dud plug heads (regardless of stems) fail to exit projectile bodies (accumulatively, i.e., two remaining in a single projectile or one
23、each remaining in two projectiles) in the live fuze ballistic tests (except in the case of a particular round that was an actual dud, in which case paragraph “i. above applies) . 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-K-71129 (4) m 999
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILK7112941996KITREFURBISHMENTFORCARTRIDGE81MMPRACTICESHORTRANGEM880LOADINGASSEMBLINGANDPACKINGM880

链接地址:http://www.mydoc123.com/p-445492.html