ARMY MIL-I-60166-1964 INVERTER POWER STATIC 10516412《10516412静态电源逆变器》.pdf
《ARMY MIL-I-60166-1964 INVERTER POWER STATIC 10516412《10516412静态电源逆变器》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-I-60166-1964 INVERTER POWER STATIC 10516412《10516412静态电源逆变器》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-1-601 66(MU) 14-May1964 . MILITARY SPECIFICATION INVERTER, POWER, STATIC: 10516412 1. SCOPE 1.1 This specification covers one type of static power inverter, that is com- pletely transistorized. The inverter is capable of inverting an 18 to 30 volt direct current potential to a 115 volt, 400 cycl
2、es per second, alternating current potential, delivering at full load 150 volt amperes. 2. APPLICABLE DOCUMENTS 2.1 The following documents, of the issue in effect on date of invitation for bids or request for proposal, form a part of this specincation to the extent specified herein. S PE CZFICATION
3、S Military MIL-F-13926 MIL-P-14232 MIL -I -266 O O MIL-1-45607 Fire Control Materiel: General Specification Parts, Equipment and Tools for Ordnance Interference Control Requirements, Aeronautical inspection Equipment, Supply and Maintenance Governing the Manufacture and inspection of Materiel, Packa
4、ging of Equipment for Ordnance STANDARDS Federal FED-STD-595 Colors FSC 1220 d Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ML-I- 60166(NU) Military MIL-STD-105 MIL-STD -1 O9 MIL-STD-171 MIL-STD-202 Sampling Procedures and Tables for Inspection Qu
5、ality Assurance Terms and Definitions Finishing of Metal and Wood Surfaces Test Methods for Electronic and Electrical by Attributes Component Parts DRAWINGS U. S, Army Munitions Command D10516412 Inverter, Power, Static: 1051 6412 PACKAGING DATA SHEET MIL-P-l4232/P10516412 Packaging of inverter, Pow
6、er, Statgc: 10516412 (Copies of specifications, standards, and drawings required by suppliers in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer, ) 3, REQUIREMENTS 3.1 Qualification. - The inverter, Power, Static
7、: 10516412 furnished under this specification shall be a product which has been tested and passed the qualification tests specified herein, and has been liated on or approved for listing on the applicable qualified products list (see 6.3). tured in accordance with Drawing DIO51 6412 and drawings per
8、taining thereto. withstandinganFquirernents of this specification. The inclosure shall be finished in accordance with Standard MIL-STD-171, System 20.8. The color shall be lusterless black, No. 37038 as specified in Standard Fed-STD-595. The dried finish shall show no running or color separation and
9、 shall present a smooth lusterless finish with no evidence of bare spots, available components wherever practical. Special components, if used, shall be cspable of fabrication by mass production methods , 3.2 Fabrication. - The inverter shall be completely transistorized-apd manufac- 3.2.1 Inclosure
10、. - The inclosure shall be made of metal capable of 3.2.2 Circuit components. - The circuitry shall employ standard commercially 2. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-1-60166 12 7477906 0336144 T = 3.2.3 Gircuitrv. - An electrical sc
11、hematic diagram shall be provided with each. inverter. This schematic shallprovide all the information required to trouble shoot ad repair the inverter,. if modules are used the circuitry ahall be shown. 3.3 General specification. - The inverter shall meet the requirements of Specification MXL-F-139
12、26, as specified below. the generalspecification and this specification, this specification shall take precedencei Should any conflict exist betwees (a) Order of precedence (b) Dimensions and tolerances (c) .hrganic protective surface finishes (d) Part identification and marking (e) Workmanship 3.4
13、Reiabilit - The inverter shall be operated continuously for 600 hours ia a horizonta + position and 400 hours in a position at 180. from the horizontal $th a direct current (dc) input of 30 volts (v) and at an ambient temperature of 150 *4.F. The rated full load output shall be maintained at 150 vol
14、t-ampere8 (VA)-with the least efficient power factor between O. 8 leading and O. 6 lagging. Subsequent to this operation, the inverter shall meet the requirements of 3.7 at room amhient tempera- ture (75 f 15.F). 3.5 .E-II-. t e requirements of 3.7 after exposure to the salt spray conditions below:
15、3.5.4 Salt s ra - The inverter shall show no evidence of finish deterioration a. The salt-solution concentration shall be 5% with a specific gravity between 1.0268 and 1.0413 Solution shall have a pH value between 6.5-and 7.2 at 95 * 3,6F. Nozzle pressure of 15 A 3 lb per square inch with an orifice
16、 of from O. 02 to O, 03 inch diameter. b. C. 3.5.5 Humid1 The inverter shall meet the requirements of 3.7 after being subjected to -7-P the o lowing relative humidity (RH) conditions: a. b. Water shall have a pH value between 6.5 and 7.5 at 77OF. Six hours exposure at 9570 RH; e hours shall be at an
17、 ambient temperature of 11 5F. c. Temperature variation of f 9*F once each hour during the next: 6 hours at an ambient temperature of 80F. Relative humidity shall be raised to 100% with condensation once each hour during the last 6 hours. (Duration of 100% RH with con- densation optional and need no
18、t coincide with hourly temperature variation. ) d. . 3.5.6 Rain. - The invel?ter shall be capable of withstanding a rainfall of . 4 inches perhour for a period of 2 hours, without visible damage or defect, and shall subsequently meet the requirements of 3.7. 3.6 Electrical. 3.6.1 Protection. 3.6.1.1
19、 Low input voltage protection. - The inverter shall not be damaged when subjected to continuous input voltages below 18 vdc with the full load connected to the output. Any output power available below 18 vdc input shall be 11 5 vdc f 10% at 400 CPS f 10%. 4. Provided by IHSNot for ResaleNo reproduct
20、ion or networking permitted without license from IHS-,-,-MSL-I- 60166(MU) 3.6.1.2 .Reverse polarity protection. - The inverter shall be inherently pro- tected aqainst applied input voltage of reverse polarity. 3.6.1.3 Short circuit and overload protection. - The inverter shall utilize automatic rese
21、t self-protective methods against short circuits and overloads in excess of 15070 of the full load (150VA). Fuses shall not be used. 3.6.2 Isolation. - The invexter housing shall be at ground potential, 3.6.3 Insulation resistance. - Unless otherwise specified on applicable drawings, al$ insulation
22、between electrically isolated circuits shall have a minimum resistance of 100 megohms with 500 vdc applied. 3.6.4 Dielectric strength. - There shall be no puncture of insulation, no sparkover, or decrease in dielectric strength when insulated areas, that are electrically isolated from ground and fro
23、m each other, are subjected to an ac root mean square (rms) potential of 1000 v plus twice the rated voltage at 60 cps for a period of not less than 3 seconds nor more than 5 seconds. 3.7 Performance. - The inverter shall meet the requirements of 3.7.1 thru 3,7,6 without spasmodic or intermittent op
24、eration with an input voltage of 24 i: 6 vdc, The voltage shall be applied to input terminals D and E, which shall be positive with respect to terminal B. All terminal designatins are those shown on Drawing Dl O51 641 2. I 3.7.1 ,Input voltage surge. - The inverter shall show no evidence of phyaical
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILI601661964INVERTERPOWERSTATIC1051641210516412 静态 电源 逆变器 PDF

链接地址:http://www.mydoc123.com/p-445445.html