ARMY MIL-I-14868-1970 INDICATOR DIGITAL DISPLAY 10559241《10559241 数字显示指示器》.pdf
《ARMY MIL-I-14868-1970 INDICATOR DIGITAL DISPLAY 10559241《10559241 数字显示指示器》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-I-14868-1970 INDICATOR DIGITAL DISPLAY 10559241《10559241 数字显示指示器》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、MILITARY SPECIFICATION INDICATOR, DIGITAL, DISPLAY: 10559241 1 Megohm) k 1.2 , 4.6. 3 103. Indicator illumination 3. 3. 1.3 4. 6.4 switch 7 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-I-1LIb 12 7777906 LIbLI77b 2 MIL -I- 148 68 (MU) 4. 3, 3 A
2、cceptance and rejection. - Rejected lots shall be screened for all defective characteristics. Removal or correction of defective units and resubmittance of rejected lots shall be in accordance with IlAcceptance and Rejection“ as specified in MIL-STD-105. 4.4 Special sampling, 4.4. 1 General. - One i
3、ndicator shall be selected at random by a Government representative as a control sample from each 100 pro- duced. The control sample shall meet the requirements and tests in Table VI. TABLE VI CONTROL TEST REQUIREMENT TEST PROCEDURE 301. Fabrication 3.1 Applicable drawings - 302, General Specificati
4、on 3.2 MIL-F-13926 - Visual Visual 4,4. 2 Environmental, - Three indicators shall be selected at random by a Government representative as a control sample from each 50 produced or from each months production, whichever occurs first. Table VIL The control samples shall meet the requirements and tests
5、 in TABLE VI1 CONTROL TEST REQUIREMENT TEST PROCEDURE 303. Storage temperature 3. 3. 2. 1 4. 6. 5. 1 3 04. Operating temperature 3. 3. 2. 2 4. 6. 5. 1 3 05. Vibration 3.3, 2. 3 4. 6. 5. 2 306, Shock 3. 3.2.4 4. 6. 53 307, Immersion 3. 3.2 5 . 4. 6, 5.4 4.4. 3 Failure of sample. - Should any one item
6、 of a special sampling fail to meet the specified test requirements, acceptance of the product shall be suspended by the Government until necessary corrections have been made by, the contractor and the resubmitted item has been approved (see 4, 3. 3). 4,5 Inspection equipment, - Except as otherwise
7、provided for by the contract, the contractor shall supply and maintain inspection equipment in accordance with the. applicable requirements of MIL-I- 45607, a c Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL -I - 148 68 ( MU) 4,5, 1 Government f
8、urnished inspection equipment. - Where the contract provides for Government furnished test equipment, and maintenance of test equipment shall be in accordance with the applicable requirements specified in MIL-1-45607, supply 4. 5, 2 Contractor furnished inspection equipment. - 4. 5. 2. 1 Government
9、design. - Unless otherwise specified in the contract, all inspection equipment specified by drawing number in specifications or SQAP forming-a part of the contract shall be supplied by the contractor in accordance with applicable technical data listed in the technical data package (TDP), 4, 5. 2. 2
10、Contractor design, - The contractor shall design and supply inspection equipment compatible with the “Test Methods and Procedures specified in 4, 6 of this specification and with the compon- ent inspection procedures specified in “Examination“ and “Te st Facili- ties“ requirements of MIL-F-13926. Si
11、nce tolerance of test equipment is normally considered to be within 100Joof the product tolerance for which it is intended, this inherent error in the test equipment design must be considered as part of the prescribed product tolerance limit. Thus, concept, construction, materials, dimensions, and t
12、olerances used in the design of test equipment shall be so selected and controlled as to insure that the test equipment will reliably indicate acceptability of a product which does not exceed 90%of the prescribed tolerance limit and permit positive rejection when nonconforming, Construction shall be
13、 such as to facilitate routine calibration of test equipment. 4, 5. 3 Test equipment. - In conjunction with 4, 5. 2, the standard test equipment listed in Table VI11 shall be utilized in performing the applicable test of 4. 6. TABLE VI11 NOMENCLATURE DESCRIPTION 1. D-C Power Supply Plus 5 *o, 2 v Ri
14、pple: 25 mV p-p max Ripple: 25 mV p-p max Ripple: 100 mV p-p max 4, Ohmmeter Range: O to 10 megohm Accuracy: rest Facilities“ require - ments of MIL-F-13926, Test methods and procedures. P 4. 6. 2 Readout selection logic, - Apply the digital type-A sig- nal to Table I3ed, in turn, to the group of te
15、rminals associated with each nixie tube specified in Table II and ob- serve the readout number on the nixie tube, numbers shall be as specified in 3. 3. 1. 1, The nixie tube readout 4. 6. 3 Laser mode control switch, - Measure for an open or short circuit condition between the terminals specified in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILI148681970INDICATORDIGITALDISPLAY1055924110559241 数字 显示 指示器 PDF

链接地址:http://www.mydoc123.com/p-445356.html