1、. MIL-F-53043 43 m 7777706 0277738 O m a - 237 - 1 o MIL-F-53043(ME) 20 July 1984 SUPERSEDING (see 6.4) MILITARY SPECIFICATION FORWARD AREA WATER POINT SUPPLY SYSTEM This specification is approved for use by the USA Belvoir Research and Development Center, Department of the Army, and is available fo
2、r use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers a portable potable water-dispensing system for use in forward areas to provide water to troop elements deployed to remote, “bare base“ desert areas. 2. APPLICABLE DOCUMENTS 2.1 Governmen
3、t documents. 2.1.1 Specifications and standards. Unless otherwise specified (see 6.21, the following specifications and standards of the issue listed in that issue of the Department of Defense Index of Specifications and Standards (DODISSI specified in the solicitation, form a part of this specifica
4、tion to the extent specified herein. SPECIFICATIONS FEDERAL TT-W-5 7 2 PPP-B-601 PPP-B-621 PPP-B-6 3 6 MILITARY MIL-C- 104 MIL-P-116 - Wood-Preservation: Water Repellant. - Boxes, Wood, Cleated-Plywood. - Boxes, Wood, Nailed and Lock-Corner. - Boxes, Shipping Fiberboard. - Crates, Wood; Lumber and P
5、lywood Sheathed, - Preservation, Methods of. Nailed and Bolted. Beneficial comments (recommendations, additions, deletions) and any pertinent I data which may be of use in improving this document should be addressed to: USA ,Belvoir Research and Development Center, ATTN: STRBE-DS, Fort Belvoir, VA ;
6、22060-5166 by using the self-addressed Standardization Document Improvement :Proposal (DD Form 1426) appearing at the end of this document or by letter. FSC 4320 THIS DOCUMENT CONTAINS 11 PAGES _ - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-
7、F-53043 q3 m 7777706 0277717 2 I! ST MIL-B-2 73 MIL-T-704 MIL-P- 7 7 5 MIL-C-1283 MIL-A-8625 MIL-G-20241 MIL-P-23377 MIL-D-43699 MIL-E-52798 MIL-S-81733 NDARDS FEDERAL - Bag, Drinking Water Storage: Cloth, Cotton Duck, Porous. - Treatment and Painting of Materiel. - Packaging of Hose, Hose Assemblie
8、s; Rubber, Dispensing, Plastic, Fabric or Metal (Including Tubing); and Fittings, Nozzles and Strainers. - Can, Gasoline, Military, 5-Gallon. - Anodic Coatings, for Aluminum and Aluminum Alloys. Gasket Material, Wool Felt, Impregnated, Adhesive, Pressure-Sensitive. - Primer Coating, Epoxy-Polyamide
9、Chemical and Solvent Resistant. - Drums, Fabric, Collapsible, Potable Water, 250- and 500-Gallon Capacities. - Pumps, Centrifugal, 2-Inch, Gasoline- or Diesel-Engine Driven. - Enamel, Alkyd, Camouflage, - Sealing and Coating Compound, Corrosive Inhibitive. FED-STD-595 - Colorr MILITARY MIL-STD-105 M
10、IL-STD-129 MIL-STD-889 MIL-STD-1186 - Sampling Procedures and Tables for Inspection - Marking for Shipment and Storage. - Dissimilar Metals. - Cushioning, Anchoring, Bracing, Blocking and by Attributes. Waterproofing: With Appropriate Test Methods. 2.1.2 Other Government documents, drawings, and pub
11、lications. The following other Government documents, drawings, and publications form a part of this specification to the extent specified herein. Drawings TA13225E9095 - Forward Area Water Point Supply System. CODE OF FEDERAL REGULATIONS Title 21 - Federal Food, Drug and Cosmetics Food Additive. 2 P
12、rovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-53043 43 7777706 0277720 7 (The code of Federal Regulations is available from the Superintendent of Documents, US Printing Office, Washington, DC 20402.) (Copies of specifications, standards, and d
13、rawings required by contractors in connection with specific acquisition functions should be obtained from the contracting activity or as directed by the contracting officer.) 2.2 Other publications. The following document(s) form a part of this specification to the extent specified herein. The issue
14、s of the documents which are indicated as DoD adopted shall be the issue listed in the current DoDISS and the supplement thereto, if applicable. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTM D 380 ASTM D 3951 - Standard Practice for Commercial Packaging. - Testing Rubber Hose. (Application
15、for copies should be addressed to the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103.) (Industry association specifications and standards are generally available for reference from libraries. using Federal agencies.) They are also distributed among technical gro
16、ups and 2.3 Order of precedence. In the event of a conflict between the text of this specification and the references cited herein, the text of this specification shall take precedence. 3. REQUIREMENTS 3.1 Description. The Forward Area Water Point Supply System (RDF), hereinafter referred to as “FAW
17、PSS“, shall be in accordance with TA13225E9095 and as specified herein. drums, a 125 gpm pumping assembly, suction and discharge hose assemblies, valves nozzles, nozzle stands and necessary ancillary items. The major components of FAWPSS include six 500 gallon 3.1.1 Drawings. The drawings forming a
18、part of this specification are end product drawings. permissible without prior approval of the contracting officer. could cumulatively result in incorrect fits, the contractor shall provide tolerances within those prescribed on the drawings to insure correct fit, assembly, and operation of the FAWPS
19、S. Any data (e.g. shop drawings, layouts, flow sheets, processing, etc.) prepared by the contractor or obtained from a vendor to support fabrication and manufacture of the production item shall be made available, upon request, for inspection by the contracting officer or the designated representativ
20、e. . No deviation from the prescribed dimensions or tolerances is Where tolerances 3.2 First article. When specified (see 6.21, a sample shall be subjected to first article inspection (see 4.3 and 6.3). 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,
21、-,- MIL-F-53043 43 W 777770b 0277723 O W 3.3 Material. Materials shall be as specified herein and on the drawings. Materials not specified shall be selected by the contractor and shall be subject to all provisions of this specification (see 3.3.2). Materials in contact with potable water shall be ce
22、rtified in accordance with Code of Federal Regulations, Title 21, parts 177 and 182 for rubber compounds in contact with potable water, 3.3.1 Material deterioration and control. The FAWPSS shall be fabricated from compatible materials, inherently corrosion and deterioration resistant or treated to p
23、rovide protection against the various forms of corrosion and deterioration that may be encountered in any of the applicable storage and operating environments to which the FAWPSS may be exposed. 3.3.1.1 Dissimilar metals. Dissimilar metals, as defined in MIL-STD-889, shall be electrically insulated
24、from one another to minimize or prevent galvanic corrosion. corrosion inhibiting sealant conforming to MIL-S-81733 or chromate tape conforming to MIL-G-20241 or a coat of epoxy primer conforming to MIL-P-23377. Protection against corrosion could also be obtained by exclusion of the electrolyte if fe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILF530431984FORWARDAREAWATERPOINTSUPPLYSYSTEM 前区水站 供水系统 PDF

链接地址:http://www.mydoc123.com/p-444785.html