ARMY MIL-DTL-53126 5 A-2012 POWER DISTRIBUTION ILLUMINATION SYSTEMS ELECTRICAL ILLUMINATION SYSTEM SINGLE PHASE [Superseded ARMY MIL-E-53126 REINST NOTICE 3 ARMY MIL-E-53126 CANC N.pdf
《ARMY MIL-DTL-53126 5 A-2012 POWER DISTRIBUTION ILLUMINATION SYSTEMS ELECTRICAL ILLUMINATION SYSTEM SINGLE PHASE [Superseded ARMY MIL-E-53126 REINST NOTICE 3 ARMY MIL-E-53126 CANC N.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-DTL-53126 5 A-2012 POWER DISTRIBUTION ILLUMINATION SYSTEMS ELECTRICAL ILLUMINATION SYSTEM SINGLE PHASE [Superseded ARMY MIL-E-53126 REINST NOTICE 3 ARMY MIL-E-53126 CANC N.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 AMSC N/A FSC 6150 Distribution Statement A. Approved for public release, distribution is unlimited. INCH-POUND MIL-DTL-53126/5A 16 OCTOBER 2012 SUPERSEDING MIL-E-53126(ME) 20 April 1992 DETAIL SPECIFICATION SHEET POWER DISTRIBUTION, ILLUMINATION SYSTEMS, ELECTRICAL ILLUMINATION SYSTEM, SINGLE PHASE
2、 This specification is approved for use within US Army Research Development and Engineering Command, Communications and Electronics Research and Development Center, Product Realization Directorate, Department of the Army and is available for use by all Departments and Agencies of the Department of D
3、efense. The requirement for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-53126. 1 SCOPE 1.1 Scope. This specification sheet covers the detail requirements for the Power Distribution Illumination Systems Electrical (PDISE), Type V, model: M46, NSN: 6150
4、-01-208-9751. 2 APPLICABLE DOCUMENTS 2.1 Drawings. The following Government drawings form a part of this specification sheet to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. DRAWING# NOMENCLATURE DRAWING # NOMENCLATURE CECOM & PM-MEP Drawing
5、s - Cage Code: 97403 and 30554 13226E7046 Utility Assembly, Electrical, Receptacles and Lighting (Copies of drawings required by contractors in connection with specific acquisition functions should be obtained from: PROJECT MANAGER-MOBILE ELECTRIC POWER, 5850 Delafield Road, Bldg 324 FT BELVOIR VA 2
6、2060-5809.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-53126/5A PAGE 2 OF 4 3 REQUIREMENTS 3.1 Requirements. The M46, Utility Kit, PDISE shall consist of the following: Quantity Description Reference 6 Extension cables 3.3.18.7* 2 Branch
7、 circuit assemblies 3.3.18.9* 2 Branch Circuit Support Rope Assemblies 3.1.2 2 Utility Lights 3.3.18.8 1 Container 3.20*, 3.1.3 8 Securing Strap 3.3.19.1* 2 In-Line GFCI 3.3.18.10* *Note: See requirement paragraph referenced MIL-DTL-53126. 3.1.1 Utility light. The light shall be a switched, fuse pro
8、tected, single tube, 40 watt, ultraviolet stable, fluorescent lamp assembly, 120 VAC, 60 Hz, operating on an input of 0.5 ampere maximum. The 48.00-inch nominal length lamp shall produce 2770 initial lumens and the light shall operate in ambient temperatures of 0 F to 140 F, at a relative humidity o
9、f up to 80 percent. The lamp ballast shall be screened to preclude electro-magnetic interference. The light shall be provided with power cables, not less than three feet long, connected to each end of the assembly, providing input and flow-through circuits. One cable shall have a straight blade, iso
10、lated ground, input plug, and the other shall have a straight blade, isolated ground, output receptacle, both conforming to UL 943. The light shall have means for bulb replacement without the use of tools. A label affixed to the light shall contain the manufacturers identification, part number, and
11、cautionary notes, at a minimum. 3.1.2 Support line. The branch circuit assembly support line shall consist of 53 0.5 feet of rope or functional equivalent, capable of supporting the cable assembly (see 3.3.18.9 in MIL-DTL-53126) with eight repositionable slides. The slides shall fit onto the line an
12、d provide a means of attachment for the support line assembly. The use or repositioning of the slides shall not abrade the line and means shall be employed to preclude the line ends fraying or loss of the slides. 3.1.3 Storage container. The reusable storage container shall be rigidly constructed of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILDTL531265A2012POWERDISTRIBUTIONILLUMINATIONSYSTEMSELECTRICALILLUMINATIONSYSTEMSINGLEPHASESUPERSEDEDARMYMILE53126REINSTNOTICE3ARMYMILE53126CANCNPDF

链接地址:http://www.mydoc123.com/p-444373.html