ARMY MIL-DTL-32415-2012 DUMMY CAP BLASTING NON-ELECTRIC 5 MINUTE INERT TIME FUSE DELAY-M32.pdf
《ARMY MIL-DTL-32415-2012 DUMMY CAP BLASTING NON-ELECTRIC 5 MINUTE INERT TIME FUSE DELAY-M32.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-DTL-32415-2012 DUMMY CAP BLASTING NON-ELECTRIC 5 MINUTE INERT TIME FUSE DELAY-M32.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-DTL-32415 06 August 2012 DETAIL SPECIFICATION DUMMY CAP, BLASTING: NON-ELECTRIC, 5 MINUTE INERT TIME FUSE DELAY-M32 This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1. Scope. This specification describes the requirements and verific
2、ation methods for the DUMMY CAP, BLASTING: non-electric, 5 minute inert time fuse delay, M32. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents in other sections of this specifica
3、tion or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Go
4、vernment documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPA
5、RTMENT OF DEFENSE STANDARDS MIL-STD-1168 - Ammunition Lot Numbering MIL-STD-1916 - DOD Preferred Methods for Acceptance of Products (Copies of these documents are available online at https:/assist.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D,
6、Philadelphia, PA 19111-5094.) Comments, suggestions, or questions on this document should be addressed to: Commander, US Army ARDEC, Attn: RDAR-QES-E, Picatinny Arsenal, New Jersey 07806-5000 or emailed to ardecstdznconus.army.mil. Since contact information can change, you may want to verify the cur
7、rency of this address information using the ASSIST Online database at https:/assist.dla.mil. AMSC N/A FSC: 1375 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,
8、-,-MIL-DTL-32415 2 2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. US ARMY ARMAM
9、ENT RESEARCH, DEVELOPMENT AND ENGINEERING CENTER (ARDEC) DRAWINGS 8830953 - Cup 13030291 - Dummy cap, blasting: non-electric, 5 minute inert time fuse delay, M32 assembly (Copies of the above drawings are available from U.S. Army RDECOM-ARDEC, ATTN: RDAR-EIS-PE, Bldg. 12, Picatinny Arsenal, NJ 07806
10、-5000 or by email at pica.drawing.requestconus.army.mil .) 2.3 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, ho
11、wever, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1. Required inspections. 3.1.1. First article. When specified, a sample shall be subjected to the first article inspection in accordance with 4.2. 3.1.2. Conformance inspection. A sampl
12、e of the M32 shall be subjected to conformance inspection in accordance with 4.3. 3.2. Materials, components, and assemblies. All materials, components and assemblies shall comply with the requirements of 13030291. 3.3. Dummy blasting cap attachment integrity. The dummy blasting cap shall not separa
13、te from the dummy fuse after exposure to not less than a 15 pound axial force for not less than 5 seconds. 3.4. Storage temperatures. The M32 shall show no evidence of material degradation after exposure to the temperature range of -65F to 165F. 3.5. Ammunition lot numbering. Ammunition lot numbers
14、shall be assigned in accordance with MIL-STD-1168. 3.6. Workmanship. All parts and assemblies shall be clean and free of burrs, sharp edges, unblended radii, surface defects, chips, dirt, grease and oil, corrosion products and other foreign matter. The dummy time fuse shall have no pin holes, bubble
15、s, breaks, discontinuity, kinks, twists, burrs, or similar defects. The dummy blasting cap shall not be cracked, bulged, scratched, or deformed. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-32415 3 3.7. Markings. All markings shall be smoo
16、th, uniform, unsmeared in appearance and free of conspicuously ragged edges. There shall be no bleeding of color markings to the extent that there is a mottled or streaky appearance. The markings shall show no lifting, wrinkling, or other visible effect on the plastics surface. The markings shall be
17、 applied on clean, dry surfaces that shall be free of dirt, oil, grease, water, corrosion, or other foreign matter. All required markings shall be present, neat, legible, only where specified, and sharply defined. 4. VERIFICATION TABLE I. Requirement/verification cross reference matrix. Method of ve
18、rification 1 - Analysis 2 - Demonstration 3 - Examination 4 - Test Classes of verification A First article B Conformance Section 3 Description Verification Methods Verification Class Section 4 1234 A B 3.1.1 First article inspection X X X 4.2 3.1.2 Conformance inspection X X X 4.3 3.2 Materials, com
19、ponents, and assemblies X X X 4.3.3.1; 4.3.3.2 3.3 Dummy blasting cap attachment integrity X X X 4.4 3.4 Storage temperatures X X 4.5 3.5 Ammunition lot numbering X X X 4.3.2 3.6 Workmanship X X X 4.3.2 3.7 Markings X X X 4.3.2 4.1. Classification of inspections. The inspection requirements specifie
20、d herein are classified as follows: a. First article inspection (see 4.2). b. Conformance inspection (see 4.3). 4.2. First article inspection. When specified, a sample shall be subjected to first article verification in accordance with Table II. 4.2.1. First article rejection. If any assembly, compo
21、nent, or test specimen fails to comply, the sample and first article shall be rejected. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-32415 4 TABLE II. First article inspections and tests. Examination or test Drawing Sample size Requirement
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILDTL324152012DUMMYCAPBLASTINGNONELECTRIC5MINUTEINERTTIMEFUSEDELAYM32PDF

链接地址:http://www.mydoc123.com/p-443618.html