1、flIL-DTL-L37LBF m 99999Ob 20753Lb 2TB m . IINCH-POUND 1 30 September 1998 SUPERSEDING 25 September 1997 MIL-DTL-13718F MIL-PRF- 1371 SE DETAIL SPECIFICATION RELAYS, ELECTROMAGNETIC 24 VOLT DC This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOP
2、E 1.1 Scope. This specification covers 24 volt direct current (Vdc) electromagnetic relays (see 6.1). 1.2 Classification. Relays are of the following types and grades as specified (see 6.2): Type 1 - Continuous duty. Type II - Intermittent duty. Grade A - Waterproof. Grade B - Nonwaterproof. 2. APPL
3、ICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents in other sections of this specification or recommended for additional information or as examples. While every effort has been made to en
4、sure the completeness of this list, document users are cautioned that they must meet ail specified requirement documents cited in sections 3 and 4 of this specification, whether or not they are listed. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of
5、 use in improving this document should be addressed to: U.S. Army Tank-automotive and Armaments Command, ATTN: AMSTA-TR-EBLUE, Warren, MI 48397-5000, by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document, or by letter. AMSC N/A FSC 2920 DISTR
6、IBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13718F 2.2 Government documents. 2.2.1 Specifications. standards. and handbooks. The following specifications, standa
7、rds, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation (see 6
8、.2). STANDARDS DEPARTMENT OF DEFENSE MIL-STD-8 1 O - Environmental Test Methods and Engineering Guidelines. (Unless otherwise indicated, copies of the above standards is available from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19 1 1 1-5094.) 2.2.2 Ot
9、her Government documents. drawings. and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. DRAWINGS ARMY 77 17664 - Relay, Current.
10、 8724750 8762321 - Relay, Solenoid. 10894808 - Relay and Housing Assembly. - Relay and Housing Assembly. (Copies of these drawings are available Com the U.S. Army Tank-automotive and Armaments Command, AT“: AMSTA-TR-EBLUE, Warren, MI 48397-5000.) 2.3 Non-Government mblications. The following documen
11、ts form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents which are DoD adopted are those listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS are the is
12、sues of the documents cited in the solicitation (see 6.2). 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13718F AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTM B117 ASTM G21 - Operating Salt Spray (Fog) Apparatus, Standard Practice
13、 - Determining Resistance of Synthetic Polymeric Materiais for. to Fungi, Standard Practice for. (Application for copies of ASTM publications may be obtained Com the American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959.) 2.4 Order of precedence. In the
14、event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When spec
15、ified (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.3. 3.2 Materials. Materials used shall be in accordance with the manufacturers materials specifications for relays. The materials shall be as specified in 3.2.1 through 3.2.3.2, and shall be capable of meet
16、ing all the operational and environmental requirements specified herein (see 4.5.1). 3.2.1 Recvcled, recovered, or environmentallv meferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible provided that the material meets or excee
17、ds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. 3.2.2 Dissimilar metals. Except where necessary to complete an electrical circuit, contact between dissimilar metals, which would encourage galvanic action, shall be avoided (see 4.5.1). 3.2.3 I
18、nsulation. 3.2.3.1 Molded. Cotton or cellulose-filled molded materials shall not be used (see 4.5.1). 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-flIL-DTL-1371BF m 9999906 2075319 TO7 H . MIL-DTL- 1 3 7 1 8F 3.2.3.2 Laminated. Cotton base lamin
19、ates shall not be used (see 4.5.1). 3.3 Design and construction. Relays shall be constructed in accordance with Drawings 7717664,8724750,8724750 and 10894808, or as specified (see 6.2). Rating of part shall be as specified on drawing and shall be based upon an ambient temperature of 77 51 5 degrees
20、Fahrenheit (“F) (25 2 8.3 degrees Celsius (“C) (see 4.5.2). 3.3.1 Locking devices. Lock washers, self-locking nuts, safety wires, or other approved locking devices shall be incorporated where specified, or where required to prevent loosening of components (see 4.5.2). 3.3.2 Electrical terminals and
21、connectors. Terminals and connectors shall conform to applicable drawings (see 3.3). Terminals shall have normal current conducting path (see 4.5.2). 3.3.3 Mounting. When brackets are used, they shall be an integral part of relay housing, or shall be securely attached thereto to prevent any movement
22、 between relay and mounting bracket in service, and to permit electrical contact to ground, if needed (see 4.5.2). 3.3.3.1 Ground. The finish around mounting .holes shall permit electrical contact to ground when relay is mounted as in intended use. Tbis requirement does not apply to relays mounted o
23、n insulated bases (see 4.5.2). 3.3.3.2 Position. Relay shall operate as specified herein when mounted in any position (see 4.5.2). 3.3.4 Polarity. Relays shall operate in negatively grounded circuits (see 4.5.2). 3.3.5 Mechanical failure. Construction shall be such that failure of linkage between ac
24、tuator and movable contacts will result in contacts moving to deenergized position when relay is deenergized (see 4.5.2). 3.3.5.1 Springs. Springs shall not be used to transmit current (see 4.5.1 and 4.5.2). 3.3.6 Weight. Weight of relay shaii be as specified on the applicable drawings (see 3.3 and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILDTL13718F1998RELAYSELECTROMAGNETIC24VOLTDC24 直流 电磁 继电器 PDF

链接地址:http://www.mydoc123.com/p-443294.html