ARMY MIL-C-45953-1974 CONTROL PANEL PILOT《导向器控制面板》.pdf
《ARMY MIL-C-45953-1974 CONTROL PANEL PILOT《导向器控制面板》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-C-45953-1974 CONTROL PANEL PILOT《导向器控制面板》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、- MIL-C-45753 30 M 7777706 0307573 4 M 22 January 1974 SUPERSEDING (See Section 6) MILITARY SPECiFICATION CONTROL PANEL, PILOT This specification is approved for use by all Depart- ments and Agencies of the Department of Defense. 1. SCOPE 1.1 This specification covers one type of pilots control used
2、 to operate the M28.Al Helicopter Armament Subsystem. incorporates switches, panel lights aiid instruments to indicate weapons employe, operational (circuit) functions and control of the amnament subsystem by the pilot. The control 2.1 The following documents, of the issue in effect on date of invit
3、ation for bids or request for proposal, form a part of this speci- fication to the extent specified herein. smIFIcAT10Ns Military MIL-W-13855 Militaq MIL-STD-O MIJrsTD=1og Weapons, Small Arms and Aircraft Armament Subsystem, General Specification For . Parts, Equipment air3 Tools For Army Materiel,
4、Packaging and Packing of. inspection Equipment, Acquisition, Maintenance and Disposition of. Sampling Procedures and Tables for Inspection by Attributes Quallty Assurance Terms and Definitions. Fsc 1010 mIS DOCUMENT CONTAINS -w PAGES, Provided by IHSNot for ResaleNo reproduction or networking permit
5、ted without license from IHS-,-,-MIL-C-45753 LO 777770b 0307572 b = U.S. Army Weapons Cod DU687987 - Control Panel, Pilot. m.JJ.637987 - List of Inspection Equipment. (Product drawings referenced in this specification form a part of Dii687987; acceptance inspection equipment drawings form a pazt of
6、mlJ-637987. 1 PUBLICATIONS U.S. Arniy Weapons Cod PU-687987 .I Packaging Data Sheet for Control Panel, pilot. (Copies of specifications, standards, drawings, and publications required by suppliers in connection with specific procurement functions should be obtained from the procuring activity or as
7、directed by the contracting officer.) 3. m- 3.1 Frst article. Requirements for submission of first article shall be as specified in the contract (see 6.2). specified (see 6.2), the first article shall include a pilot pack (see 3.2 Materials, construction and design. The control panel shall Unless ot
8、herwlse 5.1). confornto the materials, construction and design requirements specified herein, on Drawing Di1687987 and in MIL=W=13855. 3.2.1 Weight. The weight of the control panel shdl not exceed 1.3 pUna. 3.3 Functional requirements. 3.3.1 Power inputs. The control panel shall met the requirements
9、 specified herein when supplied with 24 to 30 volts direct current (vdc) with a minimum current of 3.0 ampheres. 3.3.2 Panel edge lights (DS3, DS4). Panel edge lights rs3 and DS4 shall illuminate when 24 = 30 vdc is applied between pin T (positive) and pin V of connector AW. 3.3.3 Switches. 2 I Prov
10、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-C-45753 LO 9797706 0307573 m M=4-45953(wc 1 3.3.3.1 Master arm switch (Sl), and Gunner/Pilot switch (S2). The master switch shall provide connections between pins A and C of connector Ag1 and the folih
11、owing A9J1 terminals: Am Terminals Switch (Sl) pin B pin L pin N pin H Position OFF open Open open Open SAFE Continuity open (See Note 1) (See Note 1) mdEn Continuity Continuity (See Note 1) (See Note 1) Note 1: positions S2: The reading etaonnector Ag1 SU be as foiows for switch A9J1 Terminals Swlt
12、ch (52) Position pin N pin H GuNlm Cont inul ty open Continuity An open circuit between pin X and pin Y of connector AgJ1 shall exist when switch (SI) is in the OW or SAFE position. between pin X an pin Y when switch (Sl) is in the ARMED position. Continuity shdl exist 3.3.3.2 Weapon select switch (
13、S3). The weapon select uwitch shaU provide the following connections to A9J1 terminals. Switch (S3) Position Am Terminals pins U and S pins U and R BorcH Connected Connected Open Circuit Connected RIGBP irmtnate when 24 - 30 vdc is applied between pin D (positive) and pin V of connector Awl. 24 - 30
14、 vc is applid between pin G (positive) and pin V of connector 3.3.4.3 Turret power (DSS) . The green light shal3. illuminate when Awl 3.3.4.4 7.b, left (DS5). The blue light sbaJ-l illuminate when 24 - 30 vdc is applied between pin P (positive) and pin V of connector Awl* 3.3.4.5 b, left (DS). The b
15、lue light SU illuminate when 24 - 30 vdc is applied between pin F (positive) and pin V of connector Am. 3.3.4.6 7.62mm, right (DS7). The blue light SW illuminate when 24 - 30 vdc is applied between ptn J (positive) and pin V of connector Am. 3.3.4.7 bm, right (DS8). The blue light shall illuminate w
16、hen 24 - 30 vdc is applied between pin E (positive) and pin V of connector Am. 3.4 WMng. The control panel shaJ1 be marked in accordance with MIL-W=13855 3.5 Workmanship. Workmanship shall be in accordance with MIL-W-13855. 4. QUfUITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection. Unless ot
17、herwise specified in the contract or purchase order, the supplier is responsible for the performance of all inspection requirements specified herein. Ex- cept as otherwise specified in the contract or order, the supplier may use his own or any other facilities suitable for the performance of the ins
18、pection requirements specified herein unless disapproved by the Government. inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services confom to prescribed requirements. The Government reserves the right to perform any of the 4 Provided by
19、IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-45953 10 = 7797906 0307575 1 i1 4.2 Quality assurance terms and definitions. Quality assurance terms and definitions used herein are in accordance with MIL-STD-109. 4.3 Classification of inspection. The inspe
20、ction requirements specified herein are classified as follows: a. b. First article inspection (see 4.4). Quality conformance inspection (see 4.5). 4.4 First article inspection. The first article (initial production unit(s) shall be submitted for inspection in accordance with contract requirements (s
21、ee 6.2). production processes to be used during quantity production. article shall be subjected to the quaiity conformance inspection specified herein and such other inspection as is necessary to determine compliance with the requirements of the contract. The first-article shall be representative of
22、 the The first 4.5 Quaiity conformance inspection. 4.5.1 Inspection lots. The formation, size, and presentation of inspection lots shall be in accordance with MILSTD-105 and Mu;-W-13855. Control panels shall be assembled from component parts that have met all inspection requirements specified herein
23、. 4.5.2 -nation. 4.5.2.1 Component parts and concurrent repair psrris. Ehmination of parts shall be performed in accordance with the criteria specified in the contract (see 6.2). Examination of these pats su1 be accomplished prior to their assembly into the end item or submission for acceptance as r
24、epair parts. 4.5.2.2 Control panels. Each control panel shall be examined as specified in Table I. The examination provisions should be applied at the earliest practical point in manufacture at which it is feasible to inspect for acceptance without risk of change in the characteristic by subsequent
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILC459531974CONTROLPANELPILOT 导向 控制 面板 PDF

链接地址:http://www.mydoc123.com/p-441465.html