ARMY MIL-B-10154 C-1961 BATTERIES PRIMARY WATER-ACTIVATED (DUNK TYPE)《水激活电池组(浸泡型)》.pdf
《ARMY MIL-B-10154 C-1961 BATTERIES PRIMARY WATER-ACTIVATED (DUNK TYPE)《水激活电池组(浸泡型)》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-B-10154 C-1961 BATTERIES PRIMARY WATER-ACTIVATED (DUNK TYPE)《水激活电池组(浸泡型)》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、MILITARY SPECIFICATION 1 November 1961 SUPERSEDING MIL-B-10154B 10 April 1953 BATTERIES, PRIMARY, WATER-ACTIVATED (DUNK TYPE) This specification has been approved by the Department of Defense and is man- datory for use by the Departments of the Army, the Navy and the Air Force. - 1. SCOPE 1.1 Scope.
2、 - This specification covers primary batteries which are inert until immersed in or filled 1.2 Classification. - Batteries shall be of the following types, as specified (see 6.1): with water for specified periods of activation and are discharged in air. Type BA-253/U. Type BA-259/AM. Type BA-292/AM.
3、 Type BA- 31 6/AM. 1.2.1 .Type designation. - The type designation of water-activated primary batteries shall be in the fol- lowing form: T L Component (see i. 2.1. i) Battery type number (see 1.2.1.2) indicator (see 1.2.1. 3) 1.2.1.1 Component. - Primary batteries are identified by two-letter symbo
4、l “BA“ followed by a hyphen. 1.2.1.2 Battery type number. - The battery type number identifies the specific battery. 1.2.1. 3 Installation indicator. - The installation indicator is composed of one or .more letters preceded by a slant line, denoting the equipment with which the battery is associated
5、, as specified herein. /AM - Airborne meteorological equipment. /U - General utility (includes) two or more installation classes: airborne, shipboard, and ground. 2. APPLICABLE DOCUMENTS .* 2.1 The following documents, of the issue in effect on date of invitation for bids, form a part of this specif
6、ication to the extent specified herein: SPECIFICATIONS FEDELSAL QQ-B-626 - Brass, Leaded and Nonleaded; Rods, Shapes, Forgings and Flat Products With QQ-C-576 - Copper Plates, Rolled Bars, Sheets, and Strips. QQ-P-330 - Phosphor Bronze Bars, Plates, Rods, Sheets, Strips, Flat Wire, and Structural an
7、d Special Shaped Sections. UU-C-201 - Cardboard, Bristol, Manila, and Railroad. PPP-B-576 - Box, Wood, Cleated, Veneer Paper Overlaid. Finished Edges (Bars, Flat :Nire and Strips). I FSC 6135 I E- f ! /-/ . . . . . AtW Copyright Communications - Electronics Command Provided by IHS under license with
8、 CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-B-LOL54C bL m 9999906 0085637 4 m . . . - . 1 . MIL-B-10154C i - - - - . . -.-. ,._._._._. - ,.I . - . - . . -, , . -. . . . .- . .,_- _ ._- FEDERAL (contd. ) PPP-B-585 - Boxes, Wood, Wirebound. PPP-B-591 - B
9、oxes, Fiberboard, Wood-Cleated. PPP-B-601 - Boxes, Wood, Cleated-Plywood. PPP-B-621 - Boxes, Wood, Nailed and Lock-Corner. PPP-B-636 - Boxes, Fiber. PPP-C-96 - Cans, Metal, 28 Gage and Lighter. PPP-C-843 - Cushioning Material, Cellulosic. PPP-T-76 - Tape, Pressure-Sensitive Adhesive, Paper, Water Re
10、sistant. _._ . . - -.- . . MILITARY MIL-W-76 - Wire and Cable, Hook-Up, Electrical, Insulated. MIL-P-116 - Preservation, Methods of. MIL-T-713 - Twine and Tape, Lacing and Tying (for Use in Electrical and Electronic Equip- ment). MIL-P-3115 - Plastic-Material, Laminated, Thermosetting, Sheets, Paper
11、-Base, Phenolic Resin. MIL-S-6872 - Soldering Process, General Specification for. ML-L-10547 - Liners, Case, Waterproof. STANDARDS FEDERAL FED-STD-595 - Colors. MILITARY MIL-STD-105 - Sampling Procedures and Tables for Inspection by Attributes. MIL-STD-129 - Marking for Shipment and Storage. MIL-STD
12、-414 - Sampling Procedures and Tables for Inspection by Variables for Percent Defective. (Copies of specifications, standards, drawings, and publications required by contractors in connection with specific procurement functions should be obtained from the procuring activity or as directed by the con
13、- tracting officer. ) 2.2 Other publications, - The following documents form a part of this specification to the extent speci- fied herein. Unless otherwise indicated, the issue in effect on date of invitation for bids shall apply. NATIONAL BUREAU OF STANDARDS Handbook H28 - Screw-Thread Standards f
14、or Federal Services. (Application for copies should be addressed to the Superintendent of Documents, Government Printing Office, -Washington 25, D. C. CONSOLIDATED CLASSIFICATION COMMITTEE Uniform Freight Classification Rules. (Application for copies should be addressed to the Consolidated Classific
15、atiqn Committee, 1 Park Avenue at 33rd St., New York 16, N. Y. ) 3, REQIREMENTS 3.1 Preproduction inspection, - Prior to production, preproduction samples as specified (see 6.1) shall be forwarded to a laboratory satisfactory to the bureau or agency concerned for the tests specified in 4.5. 3.2 Mate
16、rial. - The material for each part shall be as specified herein. When a definite material is not specified, a suitable material shall be used. Acceptance or approval of any constituent material shall not be construed as a guaranty of the acceptance of the finished battery. form to Specification MlL-
17、W-76. 3.2.1 m. - When insulated wire is used for electrical connectors and terminal leads, it shall con- . . . : . . -y - - . . . , . , . . . I . . i . . . . . . ,. . . . ;:.: . . . . . i . . . ._.I. _-.-_-I_- - - _-. - _.-_-I_ ._-_-._I-. 1 _.-.- ._-_-_I- . .-a - . ,- ._.- . - . . . .-. - . ._ . - .
18、 .-.-. =- .I I. _._I._ - . . . . . . - 7.: ,. . _ . . i. _.I 1 . .,. _ 2 I Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-flIL-B-10154C 61 m 7777706 0085638 6 m n u(+/ / .e3 L7 M
19、IL-B-10154C 3.2.2 Brass. - Brass used for purposes other than internal construction of the cell shall conform to Specification QQ-B-626. 3.2.3 Copper. - Copper used for purposes other than internal construction of the cell shall conform to 3.2.4 Phosphor bronze. - Phosphor bronze used for purposes o
20、ther than internal construction of the 3.3 Design and construction. - The batteries shall be of the design, construction, physical dimensions, Specification QQ-(2-576. cell shall conform to Specification QQ-P-330. weight, voltages, and polarity specified (see 3. 7). The battery shall be constructed
21、for simple and rapid activation for service. The total time for activating and preparing the battery for use shall not exceed the specified time (see 3.7). 3.3.1 internal connections. - All connections shall be securely made. Connections between cells may be made with bare wire or suitable equivalen
22、t. Wire soldered to terminal lugs shall not be bared more than one-eighth of an inch from the lugs, nor extended more than one-eighth inch beyond the lugs. 3.3.2 Terminals. - The type, dimensions, and spacing of terminals shall be as specified (see 3.7). Terminals shall provide a positive means of m
23、aking and maintaining external electrical connections to the battery. Contact surfaces of the terminals shall not be obstructed by wax or other insulating compounds. 3.3.2.1 Socket-type terminals. - Contact portions of socket-type terminals shall be made of spring phosphor bronze or plated spring br
24、ass. Sockets shall be of such design, construction, and material as to minimize leakage, current between terminals and to prevent the short circuiting of terminals, or even mo- mentary contact of any of the pins of the mating plugs to any socket terminal other than those for which such pins are inte
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILB10154C1961BATTERIESPRIMARYWATERACTIVATEDDUNKTYPE 激活 电池组 浸泡 PDF

链接地址:http://www.mydoc123.com/p-440767.html