ARMY A-A-52574 A-2003 THEODOLITES SURVEYING DIRECTION SECOND ORDER《测量方向的经纬仪 第二阶》.pdf
《ARMY A-A-52574 A-2003 THEODOLITES SURVEYING DIRECTION SECOND ORDER《测量方向的经纬仪 第二阶》.pdf》由会员分享,可在线阅读,更多相关《ARMY A-A-52574 A-2003 THEODOLITES SURVEYING DIRECTION SECOND ORDER《测量方向的经纬仪 第二阶》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、 Beneficial comments, recommendations, additions, deletions, clarifications etc., and any other data which may improve this document should be sent to: ENGINEER RESEARCH AND DEVELOPMENT CENTER, CORPS OF ENGINEERS, U.S. ARMY TOPOGRAPHIC ENGINEERING CENTER, ATTN CEERD-TS, 7701 TELEGRAPH ROAD, ALEXANDR
2、IA, VA 22315-3864. AMSC N/A FSC 6675 Distribution Statement A. Approved for public release; distribution is unlimited. A-A-52574A October 31, 2003 SUPERSEDING A-A-52574 May 15, 1998 COMMERCIAL ITEM DESCRIPTION THEODOLITES, SURVEYING, DIRECTION: SECOND ORDER The General Services Administration has au
3、thorized the use of this Commercial Item Description (CID) for all federal agencies. The original issue of this CID replaced MIL-T-14132. 1. SCOPE. This CID covers two types of illuminated theodolites with accessories, cases, and tripods. 2. CLASSIFICATION. The theodolite will be one of the followin
4、g types, as specified (see 7.3): Type I - Auto-reading digital direction-type Type II - Optical-reading direction-type Class 1 1 second Class II 0.002 mil 3. SALIENT CHARACTERISTICS. 3.1 Description. Theodolites shall be a direction-type, capable of second order accuracy (see 7.7), and capable of di
5、splaying readings in seconds and mils. Each theodolite, including the telescope, horizontal and vertical circles, circle reading system, leveling device, integral illumination system, and tribrach, shall weigh not more than 8.0 kg. Each theodolite shall be furnished with a carrying case, a theodolit
6、e cover, and when specified, a transport case, a battery and lighting accessory case, tools and accessories, and a tripod. METRIC Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52574A 2 3.2 Theodolite characteristics. Theodolites shall be an aut
7、o-reading digital or an optical-reading direction-type. 3.2.1 Telescope. The telescope shall be mounted so that pointings may be made to the zenith by use of an elbow eyepiece. The telescope shall have a means for illuminating the reticle and a means for controlling the illumination. The stadia rati
8、o shall be 1/100. The telescope shall display an erect image. The reticle shall have a pattern similar to figure 1. 3.2.1.1 Telescope eyepiece. The telescope eyepiece shall contain a diopter scale plainly marked in plus or minus units and shall have an index mark referencing the setting. 3.2.1.1.1 E
9、lbow eyepiece. Unless otherwise specified (see 7.3), the elbow eyepiece shall enable an operator to observe vertical angles to the zenith and to observe an azimuth mark, with the telescope in either the direct or reverse position. The eyepiece shall give an erect image of the reading scales. 3.2.1.1
10、.2 Solar filter. Unless otherwise specified (see 7.3), a solar filter shall be provided that shall fit both the telescope eyepiece and the elbow eyepiece. 3.2.1.1.3 Auto-collimation eyepiece. When specified (see 7.3), an auto-collimation eyepiece shall be furnished. The eyepiece shall be interchange
11、able with the standard eyepiece. The magnification of the telescope with the auto-collimation eyepiece installed shall be not less than 18 diameters. 3.2.2 Optical plummet. The optical plummet shall produce a clear image throughout the operating range, from tripod height to not less than 30.5 meters
12、. 3.2.3 Circle identification. The images of or readouts from the horizontal and vertical circles shall be identified. 3.2.4 Microscope. For type II, a microscope shall be provided to view the horizontal and vertical circles and breakdown scales, simultaneously. The images of the horizontal and vert
13、ical circles, index lines and breakdown scales shall appear erect and in the same plane. The graduation interval of the micrometer shall be 1 second for class I circles, or 0.002 mil for class II circles. 3.2.5 Microprocessor and control/display panel (for type I only). 3.2.5.1 Microprocessor. The m
14、icroprocessor shall have a nonvolatile memory with sufficient capacity to store all data, constants, operating parameters, and sufficient random access memory to perform required data reductions. 3.2.5.2 Control/display panel. The panel shall contain all function keys, an alpha-numeric display unit,
15、 and a means to record and process data. All keys shall be clearly identified as to function. Receptacles shall be labeled according to function. Warning and indicator lights required for operation of the instrument shall also be located on the panel. The panel shall automatically display observed h
16、orizontal and vertical angles at a precision and repeatability required to satisfy second order accuracies. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52574A 3 3.2.6 Levels. The instrument shall be equipped with a leveling capability which a
17、llows horizontal and vertical angle measuring at the precision and repeatability required to satisfy second order accuracies. 3.2.6.1 Vertical circle indexing. For type II, vertical circle indexing shall be controlled by a self-indexing device, unless an altitude level is specified (see 7.3). When t
18、he vertical circle in the direct position reads 90 degrees or 1600 mils, the telescope shall be horizontal. 3.2.6.2 Self-indexing device. The self-indexing device for type II theodolites shall be damped so that oscillation is stopped in not greater than 5 seconds of time. The device shall be accurat
19、e to within 10 seconds of arc or 0.05 mil. 3.2.6.3 Altitude level. On type II theodolites, when an altitude level is specified (see 7.3), the vertical circle shall be ungraduated but shall have a sensitivity 30 seconds, 5 seconds for class I, and 0.15 mil, 0.03 mil for class II, for each 2 mm. 3.2.7
20、 Tribrach. The tribrach shall consist of the leveling screws, base plate, and a device for locking the theodolite assembly. The base plate shall have at its center a 5/8-inch nut of the unified coarse thread series (0.625-11 UNC-2B) for compatibility with existing equipment. 3.2.8 Illumination. Illu
21、mination shall be by natural and artificial means. 3.2.8.1 Natural illumination. The theodolite shall be readable in all daylight conditions. For type II theodolites, natural illumination shall be useable at any orientation. 3.2.8.2 Artificial illumination. No light shall be visible beyond a 30.5 me
22、ter circle with the instrument as center point, under moonless and starless night conditions. All externally visible light produced shall be intensity adjustable. 3.2.8.3 Handlamp. For type II theodolites, when specified (see 7.3), a handlamp shall be provided and shall have connecting cord not less
23、 than 1.5 meters long. 3.2.8.4 Battery and lighting accessory case. For type II theodolites, when specified (see 7.3), a case that shall not be damaged when dropped from carrying height, at any operating temperature specified herein, shall be provided. The case shall provide mounting for batteries t
24、hat shall provide power for the handlamp and theodolite. The case shall provide space for storage of the hand lamp, connector cords, and any spares. The case shall have a provision for mounting on the tripod. 3.2.9 Power System 3.2.9.1 Power. Theodolites shall operate from an internal or external ba
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYAA52574A2003THEODOLITESSURVEYINGDIRECTIONSECONDORDER 测量 方向 经纬仪 第二 PDF

链接地址:http://www.mydoc123.com/p-440158.html