1、 Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to DAMI_STANDARDIZATIONconus.army.mil or U.S. Army RDECOM, Tank Automotive Research, Development and Engineering Center, ATTN: RDTA-EN/STND/TRANS MS #268, 6501
2、 E. 11 Mile Road, Warren, MI 48397-5000. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil. ASMC N/A FSC 3820 INCH-POUND A-A-52558A 14 September 2010 SUPERSEDING A-A-52558 20 February 1
3、996 COMMERCIAL ITEM DESCRIPTION BREAKERS, PAVING, PNEUMATIC-POWERED; (0.875 INCH HEXAGON BY 3.25 INCH CHUCK) The General Services Administration has authorized the use of this commercial item description (CID) for all federal agencies. 1. SCOPE. This CID covers a 35 pound (lb) 16 kilograms (kg) pneu
4、matic-powered, paving breakers intended for use in breaking up concrete, brick, macadam pavement, loosening compacted gravel and stiff clay. 2. CLASSIFICATION 2.1 Types. The pneumatic-powered paving breakers shall be of two types. Type I utilizes a D-grip handle, and Type II utilizes a T-handle. 3.
5、SALIENT CHARACTERISTICS 3.1 Description. The length of the pneumatic paving breaker (hereinafter referred to as “breaker”), for Type I and Type II breakers, less attachment, shall not be more than 21 inches (in.) and 31 inches (in.) 573 millimeters (mm) and 787 mm respectively. Each type of breaker
6、shall consist essentially of a backhead equipped with a handle and trigger throttle, and a cylinder with chuck and fronthead. At 90 pounds per square inch gage (psig) 621 kilopascals (kPa), the total air consumption of the breaker shall not exceed 46 cubic feet per minute (ft3/min). The breaker desi
7、gn and construction shall be representative of a standard commercial paving breaker with a history of durability and performance, which also meets the requirements of this CID. 3.2 Materials. The materials used for the breaker shall be produced to comply with the requirements and provisions of this
8、CID. The breaker shall be fabricated from compatible materials that are inherently corrosion resistant or treated in order to provide protection against Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52558A 2 the various forms of corrosion and d
9、eterioration. Dissimilar metals shall not be used in intimate contact with each other unless protected against galvanic corrosion. Recovered materials shall be used to the maximum extent practicable. Materials not specified shall be selected by the contractor and shall be subject to all provisions o
10、f this CID. Asbestos, cadmium, and radioactive material will not be used in this item. Radioactive material is defined by Title 10, Code of Federal Regulations, Part 40, and other radioactive material in which the radioactivity is greater than 0.002 microcuries per gram or 0.01 microcuries total act
11、ivity for the item. 3.3 Performance. The force of blow of the breaker shall be not less than 9 foot-pounds (ft-lb) (12.20 Newton-meters (N-m) per blow under vertical operating conditions with no extra force applied on top of the breaker. The piston speed at no load shall be not less than 1800 blows
12、per minute. The breaker shall break a 2 in. (51 mm) or thicker slab of Portland cement concrete. The breaker using the spade in cohesive soil shall operate in all positions from the vertical to the horizontal. The breaker shall accomplish the tasks without evidence of mechanical failure, malfunction
13、, permanent deformation, breakage of any part or component, evidence of wearing of the piston diameter or cylinder diameter of more than 0.001 in. (0.0254 mm), absence of oil vapor in the exhaust air and failure to break the slab of Portland cement concrete. Performance shall be unimpaired at any am
14、bient temperature from -25 degrees Fahrenheit (F) to 120 F -32 degrees Celsius (C) to 49 C. 3.4 Maintainability and reliability. 3.4.1 Maintenance support. Technical manuals, illustrating repair parts and recommended operation and scheduled maintenance, shall be furnished with each breaker. All repa
15、ir parts having the same part number shall be functionally and dimensionally interchangeable. 3.5 Surfaces. All edges shall be rounded or chamfered, and all parts, components, and assemblies of the breaker including surfaces shall be clean, and free from sand, dirt, firs, pits, sprues, scale and oth
16、er harmful or extraneous materials. 3.6 Noise limits. Noise levels shall not exceed 85 decibels dB(A) at operating positions during typical load operations. If it can be shown that 85 dB(A) is beyond the state of the art for this equipment, then a hearing protection warning decal shall be placed on
17、the equipment stating that hearing protection is required within (specify) feet. The distance specified shall be the greatest distance at which 85 dB(A) is met. The decal shall be readable to all personnel exposed to the hazard. Warnings shall also be added to applicable manuals requiring hearing pr
18、otection to be worn within the specified distance. 3.7 Backhead assembly. The backhead assembly shall include a housing, handle, throttle, and throttle valve. The handle for type I shall be D-grip and for type II shall be extension T-handle. The throttle for type I shall be positioned inside the D-g
19、rip. The throttle shall be located for operating from either side of the breaker by the operator. A self-closing lever type throttle shall be furnished. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52558A 3 3.8 Cylinder assembly. The cylinder
20、assembly shall include a cylinder, valve mechanism, piston, and chuck. The valve mechanism shall control the direction of the air to the piston. The piston shall be a combination piston-hammer. The chuck shall be dimensioned to receive standard accessories having collared hexagon shanks 0.875 in. (2
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYAA52558A2010BREAKERSPAVINGPNEUMATICPOWERED0875INCHHEXAGONBY325INCHCHUCKPDF

链接地址:http://www.mydoc123.com/p-440155.html