ARMY A-A-52510 B-2010 GENERATOR TACHOMETER《测速发电机》.pdf
《ARMY A-A-52510 B-2010 GENERATOR TACHOMETER《测速发电机》.pdf》由会员分享,可在线阅读,更多相关《ARMY A-A-52510 B-2010 GENERATOR TACHOMETER《测速发电机》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to DAMI_STANDARDIZATIONconus.army.mil or U.S. Army RDECOM, Tank Automotive Research, Development and Engineering Center, ATTN: RDTA-EN/STND/TRANS MS #268, 6501
2、E. 11 Mile Road, Warren, MI 48397-5000. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil. AMSC N/A FSC 6680 INCH-POUND A-A-52510B February 16, 2010 SUPERSEDING A-A-52510A 09 June 2009
3、COMMERCIAL ITEM DESCRIPTION GENERATOR, TACHOMETER The General Services Administration has authorized the use of this commercial item description (CID) for all Federal Agencies. 1. SCOPE This CID covers requirements for a direct current (DC) generator, tachometer which is used to measure rotational v
4、elocity/speed by converting mechanical rotation into a DC output voltage. This item is used on, but is not limited to, the M901 TOW anti-tank combat vehicle. 2. SALIENT CHARACTERISTICS 2.1 Materials. The materials used in the manufacture of the generator, tachometer shall be in accordance with the m
5、anufacturers materials specifications as required to meet the salient characteristics of this CID. The use of recovered material made in compliance with regulatory requirements is acceptable providing that all requirements of this CID are met (see 5.4). 2.2 Design and construction. Unless otherwise
6、specified in figure 1, the design and construction of the generator, tachometer shall be in accordance with the manufacturers specifications and drawings. The major components of the generator, tachometer are: rotor, stator (field) with keeper, and brush assembly. These components when supplied indi
7、vidually for assembly of the generator, tachometer at installation, shall come only in matched sets (see 2.6.2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52510B 2 PIN Former Part Number A52510-1 12265503 NOTES: 1. Each terminal (1 and 2) t
8、o accept one 20 AWG stranded wire maximum. Brush rigging terminal marking (1 and 2) to be installed to match stator terminal marking (1 and 2). 2. Dimensions are in inches. Unless otherwise specified, tolerances are 0.005. FIGURE 1. Generator, tachometer. 2.3 Technical characteristics. The technical
9、 characteristics of the generator, tachometer shall be as specified in table I. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52510B 3 TABLE I. Technical characteristics. Technical characteristics Value DC resistance Insulation resistance Diele
10、ctric withstanding voltage Speed range (normal) Generator (voltage) sensitivity Load resistance (output) Ripple voltage 87.3 ohms 1.25 ohms 100 megohms at -65F (-54C) to 77F (25C) 25 megaohms at 140F (60C) with 100V DC applied 200V rms at 60 Hz for 60 seconds with less than 1mA leakage current 20.94
11、 to 209.40 milliradians per second 0.194 10% volts per radian per second 10 000 ohms minimum 7% average to peak 2.3.1 Verification of technical characteristics. The technical characteristics shall be verified in accordance with the following tests. Normal room conditions are defined as a temperature
12、 of 77 18 F (25 10 C), relative humidity of 20 to 80 percent, and normal atmospheric pressure. a. DC resistance. The assembled generator shall have direct current resistance of 87.3 1.25 ohms under normal room conditions. b. Insulation resistance. The assembled generator shall have an insulation res
13、istance of greater than 100 megohms at -65.2F to 77F and greater than 25 megohms at 140F with 100 Vdc applied between the generator terminals and the rotor stack. c. Dielectric withstanding voltage. The dielectric withstanding voltage of the electrical insulation shall be 200 Vrms, at 60 Hz applied
14、for 60 seconds between the generator terminals and the rotor stack under normal room conditions. d. Generator sensitivity. Generator sensitivity in either direction in the normal speed range (20.94 milliradian per second to 209.40 milliradian per second) shall be 0.194 0.0194 V per radian per second
15、. The tolerance shall include all effects of nonlinearity. The generator sensitivity, using an output load of 10,000 ohms, shall be calculated from the following formula: Sensitivity (volt/radian/second) = Volts X Seconds Revolutions X 6.28 Nonlinearity tests shall be performed under normal room con
16、ditions with speeds selected between 6 and 600 milliradians per second. Two tests shall be performed with speeds at least 500 milliradians per second apart. e. Ripple. The generator percent ripple, using an output load of 10,000 ohms, shall be calculated from the following formula: Percent ripple =
17、100 X difference voltage average signal level voltage Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52510B 4 Tests shall be performed under normal room conditions with speeds selected between 6 and 600 milliradians per second. Two tests shall b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYAA52510B2010GENERATORTACHOMETER 测速 发电机 PDF

链接地址:http://www.mydoc123.com/p-440059.html