ARI 275-1997 Application of Sound Rating Levels of Outdoor Unitary Equipment《户外单一设备声音等级级别应用》.pdf
《ARI 275-1997 Application of Sound Rating Levels of Outdoor Unitary Equipment《户外单一设备声音等级级别应用》.pdf》由会员分享,可在线阅读,更多相关《ARI 275-1997 Application of Sound Rating Levels of Outdoor Unitary Equipment《户外单一设备声音等级级别应用》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、1997 STANDARD for A I R-CON D IT1 ON I N G & R E F R I G E RAT1 ON INSTITUTE APPLICATION OF SOUND RATING LEVELS OF OUTDOOR UNITARY EQUIPMENT Standard 275 4301 NORTH FAIRFAX DRIVE ARLINGTON, VIRGINIA 22203 Copyright Air-Conditioning and Refrigeration Institute Provided by IHS under license with ARINo
2、t for ResaleNo reproduction or networking permitted without license from IHS-,-,-STD-AR1 275-ENGL 1797 D 0352120 0011080 TT2 IMPORTANT SAFETY RECOMMENDATIONS It is strongly recommended that the product be designed, constructed, assembled and installed in accordance with nationally recognized safety
3、requirements, appropriate for products covered by this standard. AM, as a manufacturers trade association, uses its best efforts to develop standards, employing state-of-the-art and accepted industry practices. However, AM does not certify or guarantee safety of any products, components or systems d
4、esigned, tested, rated, installed or operated in accordance with these standards or that any test conducted under its standards will be non-hazardous or free from risk. Price $15.00 (M) 330.00 (NM) Printed in U.S.A. Note: This Standard supersedes AR1 Standard 275-84. Bps d. Copyright 1997, by Air-co
5、nditioning and Refrigeration Institute Registered United States Patent and Trademark Ofce Copyright Air-Conditioning and Refrigeration Institute Provided by IHS under license with ARINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STD-AR1 275-ENGL 1797 0352320 OOLL
6、OBL 737 SECTION TABLE OF CONTENTS PAGE Section1 . Purpose . 1 Section2 . Scope 1 Section3 . Definitions 1 Section 4 . Procedure for Estimating A-Weighted SoundPressureLevels . 1 4.1 Introduction 1 4.2 Procedure for Estimating Sound Pressure Levels . Single Unit Installation 6 4.3 Procedure for Estim
7、ating Sound Pressure Levels . Multiple Unit Installation . 6 4.4 Points of Evaluation . 6 4.5 Examples 7 Section 5 . Recommended Practices . 11 Section 6 . Voluntary Conformance . 12 TABLES Table 1 . Application Factors for Estimating A-Weighted Sound Pressure Level . 2 Table 2 . Distance Factor . 5
8、 Table 3 . Values Used for Combining Numbers for Multi-Unit Installations 6 Table 4 . Expected Reduction with Barrier 12 APPENDICES Appendix A . References . Normative . 13 Appendix B . References . Informative 13 Copyright Air-Conditioning and Refrigeration Institute Provided by IHS under license w
9、ith ARINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish for outdoor unitary equipment: definitions, procedures for estimating A-Weighted sound pressure levels, and recommended application p
10、ractices. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. 1.12 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. Ibis standard app
11、lies to the outdoor sections of factory-made air-conditioning and heat pump equipment, as defiied in Section 3 and ARi Standard 210D40 when rated in accordance with ARI Standard 270. Section 3. Definitions STDaARI 275-ENGL 1777 D 0352320 OOLLO82 875 W AR1 STANDARD 275-97 APPLICATION OF SOUND RATING
12、LEVELS OF OUTDOOR UNITARY EQUIPMENT 3.1 D&nitbns. AU terms in this document will follow the standard industry definitions established in the current edition of ASHRAE Terminology of Heating, Ventilation, Air Conditioning and Refrigeration, unless otherwise defined in this section. 3.2 equipment rate
13、d in accordance with ARI Standard 270. Sound Rating Level. lat number which is assigned to 32.1 Standard Sound Rating Level. That number assigned to equipment rated at Standard Rating Conditions in accordance with ARI Standard 270. 33.2 Application Sound Rating Level. A number assigned to equipment
14、rated in accordance with ARI Standard 270 at conditions other than Standard Rating Conditions. 3.4 C-Weighted Sound Pressure Level. As used herein, the sound pressure level, as measured on the “C“ scale of a sound level meter manufactured in accordance with the provisions of ANSI Standard S1.4. 3.5
15、“Shall,“ “Should,“ “Recommended,“ or “It Is Recommended.“ “Shall,“ “should,“ “recommended,“ or “it is recommended“ shall be interpreted as follows: 35.1 Shall. Where “shall“ or “shall not“ is used for a provision specified, that provision is mandatory if compliance with the standard is claimed. 3.52
16、 Should, Recommended, or It Is Recommended. “Should,“ “recommended,“ or “it is recommended“ is used to indicate provisions which are not mandatory but which are desirable as good practice. Section 4. Procedure for Estimating A-Weighted Sound Pressure Levels 4.1 Introduction. AR1 Standard 270 establi
17、shes a method of rating outdoor unitary equipment in terms of AR1 Sound Rating Levels. The sound level of outdoor unitary equipment in various applications is dependent not only upon the ARI Sound Rating Level but also upon several significant factors related to the application of the equipment. The
18、se factors include equipment location, barrier shielding, sound path, and distance, as described in 4.1.1 through 4.1.4 and Table 1. Quantitative values for each of these factors are established to adjust the sound rating level. The summation of the sound rating levels and applied adjustments equal
19、the estimated A-Weighted sound pressure level. The rating method in ARI Standard 270 incorporates an adjustment which is applied in the presence of tones. This method may result in slightly higher predicted sound levels than measured sound levels when following the procedures described in this stand
20、ard. 4.1.1 Equipment Location Factor. This factor takes into consideration the effect of walls and other reflective surfaces adjacent to the equipment. Factors for typical equipment locations are given in Item 1, Table 1, and described with sketches. 33 A-Weighted Sound Pressure Level. As used herei
21、n, the sound pressure level, as measured on the “A“ scale of a sound level meter manufactured in accordance with the provisions of ANSI Standard S1.4. Copyright Air-Conditioning and Refrigeration Institute Provided by IHS under license with ARINot for ResaleNo reproduction or networking permitted wi
22、thout license from IHS-,-,- STD.ARI 275-ENGL 1777 0352320 001183 701 W AR1 STANDARD 275-97 1. Equipment Location Factor a. Equipment on ground or roof or in side of building wail with no adjacent reflective surface within b. Equipment on ground or roof or in side of building wall with a single adjac
23、ent reflective surface 10 ft. 3 m (d greater than 10 ft. 3 m) within 10 ft. 3 m (d less than 10 ft. 3 m) I Table 1. Application Factors for Estimating A-Weighted Sound Pressure Levels Factor Value 068 368 d in Side of Buiiding Single Reflective Surface On Ground or Roof I wall within 10 ft. 3 m of t
24、wo adjacent walls forming an inside comer (d less than 10 ft. 13 m to both surfaces) On Ground or Roof Two Adjacent Reflecting Surfaces In Side of Building Two Adjacent Reflecting Surfaces 2 Copyright Air-Conditioning and Refrigeration Institute Provided by IHS under license with ARINot for ResaleNo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARI2751997APPLICATIONOFSOUNDRATINGLEVELSOFOUTDOORUNITARYEQUIPMENT 户外 单一 设备 声音 等级 级别 应用 PDF

链接地址:http://www.mydoc123.com/p-429429.html