ARI 1160-2008 Performance Rating of Heat Pump Pool Heaters.pdf
《ARI 1160-2008 Performance Rating of Heat Pump Pool Heaters.pdf》由会员分享,可在线阅读,更多相关《ARI 1160-2008 Performance Rating of Heat Pump Pool Heaters.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、 Price $15.00 (M) $30.00 (NM) 8Copyright 1994, by Air-Conditioning and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office 2008 Standard for Performance Rating of Heat Pump Pool Heaters ARI Standard 1160Copyright Air-Conditioning, Heating and Refrigeration
2、Institute Provided by IHS under license with ARI Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-Price $10.00 (M) $20.00 (NM) Copyright 2008, by Air-Conditioning and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office Note
3、: This standard supersedes ARI Standard 1160-2007. ARI CERTIFICATION PROGRAM PROVISIONS Scope of the Certification Program The certification program includes only Heat Pump Pool Heaters that are electrically driven, mechanical compression type systems as defined in the standard. Equipment covered: T
4、he program applies to Heat Pump Pool Heaters having 60 Hz single-phase or three-phase compressors. Certified Ratings The following ratings are verified by test: a. Standard Rating Heating Capacity - High Air Temperature, Btu/h W b. Standard Rating COP - High Air Temperature, watts/watt W/W c. Standa
5、rd Rating Heating Capacity - Low Air Temperature, Btu/h W d. Standard Rating COP - Low Air Temperature, watts/watt W/W IMPORTANT SAFETY DISCLAIMER ARI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed
6、or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AR
7、I uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. ARI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Copyright Air-Conditioning, Heating and Refrigeration
8、 Institute Provided by IHS under license with ARI Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE OF CONTENTS SECTION PAGE Section 1. Purpose .1 Section 2. Scope 1 Section 3. Definitions1 Section 4. Classifications 2 Section 5. Test Requirements .3 Section 6.
9、 Rating Requirements 3 Section 7. Minimum Data Requirements for Published Ratings 4 Section 8. Operating Requirements 4 Section 9. Marking and Nameplate Data 5 Section 10. Conformance Conditions .5 TABLES Table 1. Classifications of Heat Pump Pool Heaters .2 Table 2. Standard Rating Conditions .3 AP
10、PENDICES Appendix A. References Normative .6 Appendix B. References Informative .6 Copyright Air-Conditioning, Heating and Refrigeration Institute Provided by IHS under license with ARI Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-Copyright Air-Conditioning, Hea
11、ting and Refrigeration Institute Provided by IHS under license with ARI Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-ARI STANDARD 1160-2008 1 PERFORMANCE RATING OF HEAT PUMP POOL HEATERS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establis
12、h for Heat Pump Pool Heaters: definitions; classifications; test requirements; rating requirements; minimum data requirements for Published Ratings; operating requirements; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industr
13、y, including manufacturers, engineers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to the rating and testing of complete factory-made Heat Pump Pool Heater re
14、frigeration systems as defined in Section 3. 2.1.1 Energy Source. This standard applies only to air-source, electrically driven, mechanical compression type systems. 2.2 Exclusions. This standard does not apply to the following: 2.2.1 Individual assemblies. 2.2.2 Unitary Air-Conditioners as defined
15、in ARI Standard 210/240, Performance Rating of Unitary Air-Conditioning and Air-Source Heat Pump Equipment, with capacities less than 65,000 Btu/h 19,000 W. 2.2.3 Unitary heat operated air-conditioning equipment. 2.2.4 Water-Source Heat Pumps as defined in ANSI/ARI/ASHRAE/ISO 13256-1, Water-Source H
16、eat Pumps Testing and Rating for Performance Part I: Water-to-Air and Brine-to-Air Heat Pumps. 2.2.5 Commercial and Industrial Unitary Air Conditioning and Heat Pump Equipment with capacities of 65,000 Btu/h 19,000 W or greater as defined in ARI Standard 340/360, Performance Rating of Unitary Air Co
17、nditioning and Heat Pump Equipment. 2.2.6 Single Package Vertical Air-Conditioners and Heat Pumps as defined in ARI Standard 390, Performance Rating of Single Package Vertical Air-Conditioners and Heat Pumps. 2.2.7 Package Terminal Air-Conditioners and Heat Pumps as defined in ARI Standard 310/380,
18、Standard for Packaged Terminal Air-Conditioners and Heat Pumps, (CSA-C744-04). Section 3. Definitions All terms in this document follow the standard industry definitions in the current edition of ASHRAE Terminology of Heating, Ventilation, Air Conditioning and Refrigeration unless otherwise defined
19、in this section. 3.1 Coefficient of Performance (COP). A ratio of the Heating Capacity in watts W to the power input values in watts W at any given set of Rating Conditions expressed in watts/watt W/W. For heating COP, supplementary resistance heat shall be excluded. Copyright Air-Conditioning, Heat
20、ing and Refrigeration Institute Provided by IHS under license with ARI Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-ARI STANDARD 1160-2008 2 3.1.1 Standard Coefficient of Performance. A ratio of the capacity to power input value obtained at Standard Rating Condi
21、tions. 3.2 Heat Pump Pool Heater. A factory-made assembly, which contains the air moving device, compressor, refrigerant-to-water heat exchanger and air-to-refrigerant heat exchanger using ambient air as the heat source. Models may consist of more than one assembly to be used together for the purpos
22、e of cooling and heating air. Models with separated assemblies shall be designed to be used together, and the requirements of rating outlined in this standard are based upon the use of matched assemblies. 3.2.1 Functions. Heat Pump Pool Heaters shall provide the function of heating pool water to ach
23、ieve a controlled temperature, but may include the functions of pool water cooling, air-heating, air cooling, air-circulating, air-cleaning, or dehumidifying. 3.3 Heating Capacity. The capacity associated with the change in water temperature, expressed in Btu/h W. 3.4 Published Rating. A statement o
24、f the assigned values of those performance characteristics, under stated Rating Conditions, by which a unit may be chosen to fit its application. These values apply to all units of like nominal capacity and type (identification) produced by the same manufacturer. As used herein, the term Published R
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARI11602008PERFORMANCERATINGOFHEATPUMPPOOLHEATERSPDF

链接地址:http://www.mydoc123.com/p-429422.html