1、MILITARY SPECIFICATION TIMER, BOMBING, TYPE A-2 1. SCOPE timer equipment, designated Type A-2. 2. bids, shall form a part of this specification to the extent specified herein: 1.1 This specification establishes the requirements for one type of bombing APPLICABLE SPECIFICATIONS AND OTHER PUBLTCATIONS
2、 2.1 The following publications, of the issue in effect on the date of invitation for . . . . - . . . , . SPECIFICATIONS Military MIL-E-5272 MIL-E-5400 U. S. Air Force 7200 . STANDARDS Military MIL-STD-129 MIL-STD-130 DRAWINGS U. S. Air Force 48H21341 Environmental Testing, Aeronautical and Associat
3、ed . Electronic Equipment, Airborne, General Specification Equipment (General Specification For) For Electronic Equipment; Aircraft, Preseriation, Packaging, Packing and Marking for Shipment Of Marking of Shipments Idcntification Mariing of U. S. MlitCiry Timer, Bombing, Type A-2 I- . . . . . . . Pr
4、operty (Copies of specifications, standards, and drawings required by. contractors in connection with specific procurement functions should be obtiTincd fwrn the Procuring Agency.or as directed by the Contracting Officer.) -3 . , . ,. . ! “.“ .-_. - k:1:.lr:.1=: . . ._ ._ . - -I . -_-_ _-.-I. .- -.-
5、.- .- . - . .- .- I _.-*_ .-.- . , . b. ,.-. . i- .- . ,. . I. I. . .I_. . .- -_ . _L . -.-.- . - _.-_ . -. . -_. , . ). . . .-.- . . . . i -. , . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-momentary surges, exclusive of heater and external load
6、s. ampere and O. 5 ampere, respectively. 3.3.1.3 Relays: ! =-=:-.x-z.:x: . - . 3.3.1.3.2 Relays shall have a minimum pull in voltage of 2 volts less than . . relays Btt . 3.3 1.3.3 .Relays trBrr shall close on 18 volts or lesq. 3.4 Construction. - The timer shall be constructed in accordance with Dr
7、awing I_-. _-_-.I-_- -._ _._. _I.-.-I.-.-.% I .-. -_-I- -, ._-.I-. . .- . No. 48H21341 and details thereof. . -. . .- -. .-.-II -_-_. I._*_ . . . . 3.4.1 .Heater. - A suitable auxiliary heater ahall be pcluded to permit correct * . - -.- -.-.-. . . . . .- .-. . . L _. -._. . b . - . , -. -.-. I- . .
8、- -. . operation at lmv temperatures. It shall be controlled by Uiermostat switch and connected ta pin G of Uie receptaclij, The thermostat nlnU suitable snap actiou I :. . : . . . I . ,. . - . .-. close at 40F and open at 50F, i. . . .I -. 8 , . 3.5 Performance: / -. .,. I .- c . . - . Provided by
9、IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- . MIL-T-7045 bb W 77777Ob 0127015 b W -3-. MIL-T-9045( USAF) 3.5.1 Operation. - The timer shall operate as specified below when terminal H is connected to a positive dc power source of proper voltage and terminal
10、I connected to the negative of the same source: (See wiring diagram shown on Drawing No. 48B21334.) 3.5.1.1 Terminal F shall be energized from terminal H. 3.5.1.2 With a positive external impulse applied to terminal C, the 1 to 4 second timing element shall be initiated. 3.5.1.3 .During the time tha
11、t terminal C is energized, power will be available to terminal A froni terminal H, 3.5.1.4 At the termination of the preset interval of the 1 to 4 second timing 3.5.1.5 One or more intermittent impulses from an external source, when applied element, power stall be applied to terminal D from terminal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILT90451953TIMERBOMBINGTYPEA2TYPEA2 炸弹 计时器 PDF

链接地址:http://www.mydoc123.com/p-428691.html