AIR FORCE MIL-PRF-87896 A-2011 PROPELLANT NITROGEN TRIFLUORIDE《三氟化氮推进剂》.pdf
《AIR FORCE MIL-PRF-87896 A-2011 PROPELLANT NITROGEN TRIFLUORIDE《三氟化氮推进剂》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE MIL-PRF-87896 A-2011 PROPELLANT NITROGEN TRIFLUORIDE《三氟化氮推进剂》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 1 MIL-PRF-87896A 04 January 2011 SUPERSEDING MIL-P-87896 NOTICE 2 14 October 2005 PERFORMANCE SPECIFICATION PROPELLANT, NITROGEN TRIFLUORIDE AMSC N/A FSC 9135 DISTRIBUTION STATEMENT AReactivated after (03Jan2011) and may be used for new and existing design acquisitions . Approved for public release
2、; distribution is unlimited. INCH-POUND Comments, suggestions, or questions on this document should be addressed to HQ Air Force Petroleum Agency (AFPET)/PTPT, 2430 C Street, Bldg 70, Area B, Wright-Patterson AFB OH 45433-7632 or e-mailed to AFPET.AFTTwpafb.af.mil. Since contact information can chan
3、ge, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-87896A ii CONTENTS PARAGRAPH PAGE 1 SCOPE . 1 1.1 Scope 1 1.2
4、Classification. 1 2 APPLICABLE DOCUMENTS . 1 2.1 General . 1 2.2 Government documents . 1 2.2.1 Specifications, standards, and handbooks . 1 2.3 Non-Government publications 1 2.4 Order of precedence . 2 3 REQUIREMENTS . 2 3.1 Chemical composition and physical properties 2 3.2 Limiting values 2 3.3 F
5、illed containers . 2 3.3.1 Cylinders . 2 3.3.2 Filling pressure . 2 3.3.3 Leakage 2 3.3.4 Identification tag . 2 4 VERIFICATION 4.1 Classification of inspections . 3 4.2 Conformance inspection . 3 4.2.1 Individual tests 3 4.2.1.1 Filling pressure . 3 4.2.1.2 Leakage 3 4.2.2 Sampling for tests . 3 4.
6、3 Sampling plan . 4 4.3.1 Lot . 4 4.3.1.1 Sample size 4 4.3.1.2 Sampling method 4 4.4 Rejection . 4 4.5 Test Methods 4 4.5.1 Purity . 4 4.5.2 Tetrafluoromethane, carbon dioxide, nitrous oxide, and sulfur hexafluoride . 5 4.5.2.1 Instrument parameters . 5 4.5.2.2 Calibration . 5 4.5.2.3 Procedure . 5
7、 4.5.2.4 Calculation 5 4.5.3 Oxygen + argon, nitrogen, and carbon monoxide 5 4.5.3.1 Instrument parameters . 6 4.5.3.2 Calibration . 6 4.5.3.3 Procedure . 6 4.5.3.4 Calculation 6 4.5.4 Total reactive fluoride as HF . 6 4.5.4.1 Fluoride ion selective electrode 6 4.5.4.1.1 Buffer solution . 6 4.5.4.1.
8、2 Calibration standard . 6 4.5.4.1.3 Procedure . 7 4.5.4.1.3.1 Calibration curve . 7 4.5.4.1.3.2 Sample preparation 7 4.5.4.1.3.3 Measurement 7 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-87896A iii 4.5.4.1.3.4 Calculation 7 4.5.4.2 Fouri
9、er Transform Infrared Spectroscopy (FTIR) . 7 4.5.5 Water 7 4.5.5.1 Electrolytic 7 4.5.5.2 Piezoelectric . 7 5 PACKAGING 7 5.1 Packaging . 7 6 NOTES . 8 6.1 Intended use . 8 6.2 Acquisition requirements 8 6.3 Packaging requirements . 8 6.4 Subject term (key word) listing . 8 6.5 Changes from previou
10、s issue . 8 TABLE I Chemical composition and physical properties . 3 II Sampling for test . 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-87896A 1 This specification is approved for use by all Departments and Agencies of the Department of
11、 Defense. 1. SCOPE 1.1 Scope1.2 . This specification covers the requirements for nitrogen trifluoride (NF3) propellant. ClassificationType I - Gaseous . Nitrogen trifluoride will be of the following type as specified (see 6.2): 2. APPLICABLE DOCUMENTS 2.1 General2.2 . The documents listed in this se
12、ction are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users a
13、re cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed. Government documents2.2.1 . Specifications, standards, and handbooksDEPARTMENT OF DEFENSE SPECIFICATIONS . The following specifications, standa
14、rds and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. MIL-PRF-27407 - Propellant Pressurizing Agent, Helium DEPARTMENT OF DEFENSE STANDARDS MIL-STD-1411 - Inspection an
15、d Maintenance of Compressed Gas Cylinders (Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Bldg 4D, Philadelphia PA 19111-5094.) 2.3 Non-Government publicationsASTM INTERNATIONAL . The foll
16、owing documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. ASTM E29 - Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications
17、ASTM F307 - Standard Practice for Sampling Pressurized Gas Analysis (Copies of these documents are available online at http:/www.astm.org or the ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken PA 19428-2959) Provided by IHSNot for ResaleNo reproduction or networking permitt
18、ed without license from IHS-,-,-MIL-PRF-87896A 2 KENNEDY SPACE CENTER KSC-SPEC-P-0022 - Solvent, Cleaning, 1,3-Dichloro-1,1,2,2,3-Pentafluoropropane, HCFC-225G, Specification For (Copies of this document is available online at http:/standards.nasa.gov/ or from NASA Technical Standards Program Office
19、, Marshall Space Flight Center, Marshall Space Flight Center, AL 35812). ASME INTERNATIONAL ASME B40.100-2005 - Pressure Gauges and Gauge Attachments (Copies of this document is available online at http:/www.asme.org/ or may be obtained from ASME Information Central Order/Inquiries PO Box 2300, Fair
20、field, NJ 07007-2300, (US/Canada (800)843-2763; outside North America (973)882-1170). 2.4 Order of precedence3. REQUIREMENTS . Unless otherwise cited herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document tak
21、es precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3.1 Chemical composition and physical properties3.2 . The chemical composition and physical properties of the propellant shall conform to Table I when tested in
22、 accordance with (IAW) the test methods in 4.5. Limiting values3.3 . The following applies to all specified limits in this specification: For purposes of determining conformance with these requirements, an observed value or a calculated value shall be rounded off “to the nearest unit“ in the last ri
23、ght-hand digit used in expressing the specification limit according to the rounding-off method of ASTM Practice E29, Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications. Filled containers3.3.1 . Cylindersa. The odor test is omitted. . Gaseous NF3
24、cylinders shall be prepared in accordance with procedures for oxygen in MIL-STD-1411 with the following exceptions: b. The cylinder and tube valve outlets shall be according to Compressed Gas Association Valve Outlet 330. The main manifold valve on the tube bank trailers shall be Circle Seal Valve P
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILPRF87896A2011PROPELLANTNITROGENTRIFLUORIDE 氟化 推进 PDF

链接地址:http://www.mydoc123.com/p-428303.html