AIR FORCE MIL-PRF-25675C-1997 VALVES CHECK MINIATURE HYDRAULIC AIRCRAFT AND MISSILE [Superseded AIR FORCE MS24423 REV C CANC NOTICE 3 AIR FORCE MS24423 REV C NOTICE 2 AIR FORCE MS2.pdf
《AIR FORCE MIL-PRF-25675C-1997 VALVES CHECK MINIATURE HYDRAULIC AIRCRAFT AND MISSILE [Superseded AIR FORCE MS24423 REV C CANC NOTICE 3 AIR FORCE MS24423 REV C NOTICE 2 AIR FORCE MS2.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE MIL-PRF-25675C-1997 VALVES CHECK MINIATURE HYDRAULIC AIRCRAFT AND MISSILE [Superseded AIR FORCE MS24423 REV C CANC NOTICE 3 AIR FORCE MS24423 REV C NOTICE 2 AIR FORCE MS2.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Beneficial comments (recommendations, additions, deletions) and any pertinent data that may be of use in improvingthis document should be addressed to: Oklahoma City Air Logistics Center/TICLA, 3001 Staff Drive, Suite 1AE1-101A, Tinker AFB, OK 73145-3036 by using the Standardization Document Improve
2、ment Proposal (DD Form 1426)appearing at the end of this document or by letter.AMSC N/A FSC 4820INCH-POUNDMIL-PRF-25675C26 NOVEMBER 1997SUPERSEDING(See 6.8)PERFORMANCE SPECIFICATIONVALVES, CHECK, MINIATURE, HYDRAULIC,AIRCRAFT AND MISSILEThis specification is approved for use by the Department of the
3、 Air Force and is available for use by allDepartments and Agencies of the Department of Defense.1. SCOPE1.1 Scope . This specification covers hydraulic, spring-loaded, normally closed aircraft and missile hydraulicsystem check valves with operating pressures up to 3,000 pounds per square inch (psi)
4、and operating temperaturesfrom -65 to 450 F.1.2 Classification . There are two styles of check valve, flared and flareless, with seven sizes of each styledesignated by part number suffixes -4, -5, -6, -8, -10, -12, and -16. The flared and flareless check valves are shown inFigures 1 and 2, respectiv
5、ely. The check valve required should be indentified in 6.2.2. APPLICABLE DOCUMENTS2.1 General . The documents listed in this section are cited in sections 3 and 4 of this specification. This sectiondoes not include documents cited in other sections of this specification or recommended for additional
6、 information oras examples. While every effort has been made to ensure the completeness of these lists, document users are cautionedthat they must meet the requirements specified in the documents cited in sections 3 and 4 of this specification, whetheror not they are listed.2.2 Government documents
7、.2.2.1 Specifications and standards . The following specifications and standards form a part of this document to theextent specified herein. Unless otherwise specified, the applicable issues of these documents are those listed in thespecific issue of the Department of Defense Index of Specifications
8、 and Standards (DoDISS) and supplement theretocited in the solicitation (see 6.2).SPECIFICATIONSDEPARTMENT OF DEFENSEMIL-H-5606 - Hydraulic Fluid, Petroleum Base; Aircraft, Missile And OrdnanceMIL-H-83282 - Hydraulic Fluid, Fire Resistant, Synthetic Hydrocarbon Base, Aircraft,Metric, NATO Code Numbe
9、r H-537Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-25675C2STANDARDDEPARTMENT OF DEFENSEMS33514 - Fitting End, Standard Dimensions for Flareless Tube Connection and Gasket Seal(Unless otherwise indicated, copies of the above specifications
10、 and standards are available from the StandardizationDocument Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)2.3 Non -Government publications . The following document forms a part of this document to the extent specifiedherein. Unless otherwise specified, the applicable is
11、sues of the documents that have been adopted by the DoD arethose listed in the specific issue of the DoDISS cited in the solicitation. Unless otherwise specified, the documents notlisted in the DoDISS are the issues of the documents cited in the solicitation (see 6.2).SOCIETY OF AUTOMOTIVE ENGINEERS
12、 (SAE)SAE AS 4395 - Fitting Ends, Flared Tube Connection, Design Standard(Application for copies should be addressed to Society of Automotive Engineers, Inc., 400 Commonwealth Drive,Warrendale, PA 15096-0001.)2.4 Order of precedence . In the event of a conflict between the text of this document and
13、the references citedherein, except for related associated specifications or specification sheets, the text of this document takes precedence.Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has beenobtained. If there is a conflict between the
14、contents of this specification and an associated specification orspecification sheet, the associated specification or specification sheet will apply.3. REQUIREMENTS3.1 Qualification . The valve furnished under this specification shall be products that are authorized by thequalifying activity for lis
15、ting on the applicable qualified products list before contract award (see 4.2. and 6.3).3.2 Recycled, recovered, or environmentally preferable materials . Recycled, recovered, or environmentallypreferable materials should be used to the maximum extent possible provided that the materials meet or exc
16、eed theoperational and maintenance requirements, and promote economically advantageous life cycle cost.3.3 Materials . All materials shall not produce toxic or deleterious fumes and shall be resistant to corrosion due toelectrolytic decomposition, hydraulic fluids, salt fog, or any other conditions
17、that may be encountered duringoperational use or storage.3.4 Interface .3.4.1 Dimensions . The weight and dimensions of the valve shall conform to Figure 1 and Figure 2.3.4.2 Hydraulic fluid compatibility . The valve shall be compatible with hydraulic fluid conforming to MIL-H-5606and MIL-H-83282 in
18、 a hydraulic system (see 6.4).Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-25675C33.4.3 Item identification . The valve shall be permanently and legibly marked with the following information:a. Manufacturers nameb. Manufacturers CAGE codec
19、. Manufacturers part number (PN)d. National Stock Number (NSN)e. Date of manufacture3.5 Environmental conditions . The valve shall operate under the following conditions:a. Temperature: 65 to 450 F.b. Vibration: (1) a frequency between 20 and 90 Hz with a 0.05 double amplitude.(2) a frequency betwee
20、n 90 and 2,000 Hz with an acceleration of 20g.3.6 Performance .3.6.1 Proof pressure . The valve shall withstand a proof pressure of 4,500 (+150, -0) psi at 450 5 F in both thefree-flow and reverse-flow directions.3.6.2 Surge flow . The valve components shall withstand 25 flow cycles (see 6.5.4).3.6.
21、3 Leakage . When the valve is held in the horizontal or vertical position, the internal leakage rate of the valveshall not exceed the values specified in Table I with the pressure applied in the reverse flow direction.TABLE I. LeakagePressure (psi) Maximum leakage rate(drops per minute)5 11,000 to 3
22、,000 None3.6.4 Checking time and cracking pressure . The checking time (see 6.5.1) of the valve shall not exceed 1.5seconds. The cracking pressure (see 6.5.2) shall be between 2 and 8 psi.3.6.5 Pressure drop . The pressure drop through the valve at rated flow shall not exceed 15 psi.3.6.6 Endurance
23、. The valve shall withstand 50,000 impulse cycles (see 6.5.5) at the rate of 30 to 100 cycles perminute (cpm) at a temperature of 450 10 F.3.6.7 Burst pressure . The valve shall withstand a maximum pressure of 7,500 psi.3.6.8 Flexural strength . The valve shall withstand flexing (see 6.5.3) at 450 1
24、0 F.3.6.9 Repeated assembly . The valve shall be capable of repeated assembly and disassembly without affecting theperformance or life of the valve.3.6.10 Workmanship . The valve shall be constructed in accordance with commonly accepted industrialworkmanship standards.Provided by IHSNot for ResaleNo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILPRF25675C1997VALVESCHECKMINIATUREHYDRAULICAIRCRAFTANDMISSILESUPERSEDEDAIRFORCEMS24423REVCCANCNOTICE3AIRFORCEMS24423REVCNOTICE2AIRFORCEMS2PDF

链接地址:http://www.mydoc123.com/p-428180.html