1、MIL-PRF-25508H 27-October-2011 SUPERSEDING MIL-PRF-25508G 21 November 2006 PERFORMANCE SPECIFICATION PROPELLANT, OXYGEN This specification is approved for use by all Departments and Agencies of the Department of Defense. AMSC N/A FSC 9135 DISTRIBUTION STATEMENT A. Approved for public release; distri
2、bution is unlimited. METRIC Comments, suggestions, or questions on this document should be addressed to AFPA/PTPT, 2430 C Street, Bldg 70, Area B, Wright-Patterson AFB OH 45433-7632 or e-mailed to AFPET.AFTTwpafb.af.mil. Since contact information can change, you may want to verify the currency of th
3、is address information using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-25508H 2 This specification is approved for use by all Departments and Agencies of the Department of Defens
4、e. 1. SCOPE 1.1 Scope1.2 . This specification covers the requirements for three grades and two types of oxygen. Classification1.2.1 . The oxygen will be of the following types and grades as specified (see 6.2). TypesType I Gaseous . The types of oxygen are as follows: Type II Liquid 1.2.2 GradesGrad
5、e A 99.6 percent pure, standard . The grades of oxygen are as follows: Grade B 99.5 percent pure, reduced standard Grade F 99.990 percent pure, fuel cell and breathing 1.3 Part or identifying number (PIN)M 25508 - X X Example of PIN: M25508-2B . The PINs to be used for oxygen acquired to this specif
6、ication are created as follows: Grade (see 1.2.2). Type (see 1.2.1). Use 1 for Type I, 2 for Type II. Specification number. Prefix for military specification. 2. APPLICABLE DOCUMENTS 2.1 General2.2 . The documents listed in this section are specified in sections 3, 4, or 5 of this specification. Thi
7、s section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of docume
8、nts cited in sections 3, 4, or 5 of this specification, whether or not they are listed. Government documents2.2.1 . Specifications, standards, and handbooks. The following standard forms a part of this document to the extent specified herein. Unless otherwise specified, the issues of this document a
9、re those cited in the solicitation or contract (see 6.2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-25508H 3 COMMERCIAL ITEM DESCRIPTION A-A-58092 Tape, Antiseize, Polytetrafluorethylene (Copies of this document is available online at h
10、ttps:/assist.daps.dla.mil/quicksearch/ or https:/assist.daps.dla.mil or by mail from the Standardization Document Order Desk, 700 Robbins Avenue, Bldg 4D, Philadelphia PA 19111-5094.) 2.3 Non-government publicationsASTM INTERNATIONAL (ASTM) . The following documents form a part of this document to t
11、he extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. ASTM E29 Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications (DoD adopted) ASTM F307 Standard Practice for Sampl
12、ing Pressurized Gas for Gas Analysis (DoD adopted) ASTM F310 Standard Practice for Sampling Cryogenic Aerospace Fluids (DoD adopted) (Copies of these documents are available online at http:/www.astm.org or by mail from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA,
13、19428-2959) COMPRESSED GAS ASSOCIATION (CGA) CGA G-4.3 Commodity Specification for Oxygen CGA P-15 Filling of Industrial and Medical Nonflammable Compressed Gas Cylinders (Copies of these documents are available online at http:/ or by mail from the Compressed Gas Association, Inc., 4221 Walney Road,
14、 5thFloor, Chantilly, VA 20151). 2.4 Order of precedence3. REQUIREMENTS . In the event of a conflict between the text of this document and the references cited herein (except for related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes
15、applicable laws and regulations unless a specific exemption has been obtained. 3.1 Grade requirements3.2 . The purity and impurity concentrations as applicable to each grade of oxygen shall conform to the limits of Table I when tested in accordance with the applicable test method also specified in T
16、able I. Other limits and tests may be specified by the procuring activity (see 6.2). Limiting values. The following applies to all specified limits in this specification. For purposes of determining conformance with these requirements, an observed value or a calculated value shall be rounded off “to
17、 the nearest unit” in the last right-hand digit used in expressing the specification limit according to the rounding-off method of ASTM E29 Standard Practice for using Significant Digits in Test Data to Determine Conformance with Specifications. Provided by IHSNot for ResaleNo reproduction or networ
18、king permitted without license from IHS-,-,-MIL-PRF-25508H 4 3.3 FilterTABLE I. Grade limits for oxygen. . A filter with no more than a 10-micrometer nominal and 40-micrometer absolute rating shall be installed between the manufacturers plant system and the manifold used to fill the gas or liquid co
19、ntainers for delivery. Grade Test Method A B F Purity, percent by volume, min 99.6 99.5 99.990 4.4.1 Impurities, ppm by volume, max 4000 5000 100 4.4.1 Total hydrocarbons as methane 50 67.7 20 4.4.2 Water 3 26.3 3 4.4.2 Methane Note a Note a 16 4.4.2 Ethane Note a Note a 2 4.4.2 Propane and higher h
20、ydrocarbons as propane Note a Note a 1 4.4.2 Nitrous oxide Note a Note a 1 4.4.2 Halogenated hydrocarbons Note a Note a 1 4.4.2 Carbon monoxide and carbon dioxide Note a Note a 1 4.4.2 Other (N, Ar, Kr, etc.) Note a Note a 75 4.4.2 Odor Note a Note a None 4.4.2 Particulateb, mg/L, max 1.0 1.0 1.0 4.
21、4.3 Notes: a. No limit for this grade. b. Applies to Type II product only. The particulate test requirement and limit may be deleted by the procuring activity (see 6.2). 3.4 Filled containers (Type I only)3.4.1 . Filling Pressure3.4.2 . The container filling pressure shall not differ from that requi
22、red by the contract by more than 1.0% at 70F when tested as specified in 4.5.1. In no case shall the filling pressure exceed the rated service pressure of the container. Pressure-Temperature Filling Charts in CGA P-15 may be used. Leakage. Cylinders shall not leak when tested according to 4.5.2. Pro
23、vided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-25508H 5 4. VERIFICATION 4.1 Points of inspection (see 6.2)4.2 . Unless otherwise specified, acceptance tests shall be conducted at the site of filling prior to shipment or departure. Conformance i
24、nspectiona. Individual tests (Type I only) 4.2.1 b. Sampling tests 4.2.2 . Quality conformance tests shall consist of the following: 4.2.1 Individual tests (Type I only)a. Filling pressure 4.5.1 b. Leakage 4.5.2 . Each container (cylinder or tube) shall be subjected to the following tests as describ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILPRF25508H2011PROPELLANTOXYGEN 推进 PDF

链接地址:http://www.mydoc123.com/p-428176.html