1、t MIL-1-83449 (USAF) 10 December 1974 MILITARY SPECIFICATION INDICATOR SET, LIQUID OXYGEN QUANTITY, A/A24J-21 This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 dicator set that is designated A/A24J-21. master indicator and .a repeater i
2、ndicator. This specification covers one type of 5-liter liquid oxygen quantity in- The indicator set consists of a 2. APPLICABLE DOCUMENTS 2.1 The following documents, of the issue in effect on date of invitation for bids or requests for proposal, form a part of this specification to the extent spec
3、ified herein, SPECIFICATIONS Mi 1 it ary MIL-1-25645 MIL-L-27160 Indicator, Liquid Oxygen Quantity, Capacitance Type, General Specification for Lighting, Instrument, Integral, White, General Spec- if ication for STANDARDS Federal FED-STD-59 Eli 1 it ary )lors MI L-STD-78 1 Reliability Tests: Exponen
4、tial Distribution MIL-STD-831 Test Reports, Preparation of MS3 3 5 5 8 Numerals and Letters, Aircraft Instrument Dial, Standard Form of FSC 6680 THIS DOCUMENT CONTAINS 9 PAGES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-1-83449 (USAF) (Copie
5、s of specifications, standards, drawings, and publications required by suppliers in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer . ) 3. REQUIREMENTS 3.1 General specification. Unless otherwise specified herein
6、, the re- quirements of section 3 of MIL-1-25645 shall apply as requirements for this specification. If the requirements of section 3 of MIL-1-25645 and the requirements of section 3 of this specification conflict, the requirements of this specification shall govern. 3.1.1 Qualification, The indicat
7、or sets furnished under this specifica- tion shall be products which are qualified for listing on the applicable qualified products list at the time set for opening of bids (see 4.1.2 and 6.3). 3.1.2 Components. and a repeater indicator. shall include all of the equipment (.except cables) necessary
8、to meet the performance requirements specified herein and in MIL-1-25645. The indicator set shall consist of a master indicator The master indicator and the repeater indicator 3.1.3 Capacitance. For design purposes, the capacitance for zero reading shall be 63.5 picofarads (PF), 3.1.4 General electr
9、ical requirements 3.1.4.1 Power-failure flag. The master indicator and the repeater indi- cator shall each have a power-failure flag. The flags shall be blank for power-on conditions and shall indicate “OFF“ for power-off conditions. 3.1.4.2 Integral lighting. The master indicator and the repeater i
10、ndi- cator shall each have integral lighting. The integral lighting shall con- form to MIL-L-27160. 3.1.4.3 Electrical connectors. The electrical connectors shall be in accordance with figures 1 and 2. indicator shall be designed internally so that they will function proper- ly when the mathg connec
11、tors are wired as shown in figures 1 and 2. The part numbers of the connectors that are specified in figures 1 and 2 are designations of the Amphenol Connector Division; 2801 South 25th Avenue; Broadview, Illinois 60153. The master indicator and the repeater 2 Provided by IHSNot for ResaleNo reprodu
12、ction or networking permitted without license from IHS-,-,-co- AX M 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-1-83449 (USAF) REPEATER INDICATOR CONNECTOR CONFORMING TO PART NO. 182-11, OR EQUAL (SEE 3. I. 4. 3 ) - -7 MASTER- PIN A NO CONN
13、ECTION MASTER- PIN D -0 5 VOLT, 400 HERTZ .E GROUND J MASTER- PIN L L MASTER-PIN M M MATING CONNECTOR CONFORMING TO PART NO, 165-10, OR EQUAL (SEE 3. I. 4. 3) -.- E J L M - - FIGUM 2. Repeater Indicator Connector Wiring 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without l
14、icense from IHS-,-,-MIL- 1-8 3449 (US AF) 3.1.5 Performance 3.1.5.1 Accuracy. When the indicator set is tested as specified in MIL-1-25645, the accuracy of the master indicator shall be in accor- dance with table I. The tolerance for the room-temperature reading is the allowable deviation from the n
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILI834491974INDICATORSETLIQUIDOXYGENQUANTITYAA24J21AA24J21 液氧 指示器 装置 PDF

链接地址:http://www.mydoc123.com/p-428010.html