AIR FORCE MIL-DTL-7560D-1997 VALVE ASSEMBLY OXYGEN CYLINDER BAILOUT《紧急跳伞用氧气瓶用阀门组件》.pdf
《AIR FORCE MIL-DTL-7560D-1997 VALVE ASSEMBLY OXYGEN CYLINDER BAILOUT《紧急跳伞用氧气瓶用阀门组件》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE MIL-DTL-7560D-1997 VALVE ASSEMBLY OXYGEN CYLINDER BAILOUT《紧急跳伞用氧气瓶用阀门组件》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、INCH-POUNDMIL-DTL-7560D20 June 1997SUPERSEDINGMIL-C-7560C23 January 1991DETAIL SPECIFICATIONVALVE ASSEMBLY, OXYGEN CYLINDER, BAILOUTThis specification is approved for use by all Departments and Agencies of the Department of Defense.1. SCOPE1.1 Scope . This specification covers manually operated, oxy
2、gen cylinder bailout valve assemblies.1.2 Classification . The valve assembly is classified according to the hose length and the actuating cable asdesignated by the applicable Part or Identifying Number (PIN) of MIL-DTL-7560/1.2. APPLICABLE DOCUMENTS2.1 General . The documents listed in this section
3、 are needed to meet the requirements specified in sections 3,4, and 5 of this specification. This section does not include documents cited in other sections of this specificationor recommended for additional information or as examples. While every effort has been made to ensure thecompleteness of th
4、is list, document users are cautioned that they must meet all specified requirements documentscited in sections 3, 4, and 5 of this specification, whether or not they are listed.2.2 Government documents .2.2.1 Specifications, and standards . The following specifications and standards form a part of
5、this documentto the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issueof the Department of Defense Index for Specifications and Standards (DODISS) and supplement thereto, cited inthe solicitation (see 6.2).SPECIFICATIONSDEPARTMENT OF DEFE
6、NSEMIL-DTL-7560/1 Valve Assembly, Oxygen Cylinder, BailoutMIL-O-27210 Oxygen, Aviators Breathing, Liquid and GasMIL-G-27617 Grease, Aircraft And Instrument, Fuel And Oxi dizer ResistantMIL-T-27730 Tape, Antiseize, Polytetrafluoroethylene, with DispenserAMSC N/A FSC 1660DISTRIBUTION STATEMENT A : App
7、roved for public release; distribution is unlimited.Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use inimproving this document should be addressed to: Technology & Industrial Services Division, OC-ALC/TICLA,Tinker AFB, OK 73145-3037 by using the
8、Standardization Document Improvement Proposal (DD Form 1426)appearing at the end of this document or by letter.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7560D2STANDARDSDEPARTMENT OF DEFENSEMIL-STD-130 Identification Marking Of US Milita
9、ry PropertyMIL-STD-1359 Cleaning Methods And Procedures For Breathing Oxygen EquipmentMS26545 Cylinder, Steel, Compressed Gas, Non-Shatterable Seemless, 1800 And 2000PSI(Unless otherwise indicated, copies of federal and military specifications, and standa rds are available from theStandardization Do
10、cuments Order Desk, Building 4D, 700 Robbins Ave, Philadelphia, PA 19111-5094)2.3 Order of precedence . In the event of a conflict between the text of this document and the references citedherein, (except for related associated detail specifications, specification sheets, or MS standards), the text
11、of thisdocument takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unlessa specific exemption has been obtained.3. REQUIREMENTS3.1 Specification sheet . The individual item requirements shall be as specified herein and in accordance withthe specification
12、sheet. In the event of any conflict between the requirements of this specification and thespecification sheet, the latter shall govern.3.2 Qualification . The valve assemblies, flow controller, and break-off nipple furnished under thisspecification shall be products which are authorized by the quali
13、fying activity for listing on the applicableQualified Products list at the time of award of contract (see 4.2 and 6.3).3.3 Materials . Materials shall conform to applicable specifications and shall be as specified herein and onapplicable drawings. Materials which are not covered by specifications, o
14、r which are not specifically describedherein, shall be of the best quality, of the lightest practicable weight, and suitable for the purpose intended.Reclaimed materials shall be utilized to the maximum extent possible within the quality limits required by thisdocument.3.3.1 Age . Elastomer componen
15、ts, other than components made from silicone, shall not be more than 12months old from the date of delivery of the valve to any Government service, or to an airframe or accessorymanufacturer.3.3.2 Protective treatment . When materials are used in the construction of the valves that are subject todet
16、erioration when exposed to environmental conditions likely to occur during service usage, they shall beprotected against such deterioration in a manner that will in no way prevent compliance with the performancerequirements of this specification. Protective coating which might crack, chip, or scale
17、during normal service lifeor under extremes of environmental conditions shall not be used.3.4 Design and construction . The valve assembly shall be designed and constructed in accordance with theapplicable dash number of MIL-DTL-7560/1.3.4.1 Flow controller . The flow controller shall be designed an
18、d constructed in accordance with MIL-DTL-7560/1 and shall contain a filter (see 6.5) that will filter all oxygen passing through the valve.3.4.2 Break-off nipple . The break-off nipple shall be designed and constructed in accordance with MIL-DTL-7560/1.Provided by IHSNot for ResaleNo reproduction or
19、 networking permitted without license from IHS-,-,-MIL-DTL-7560D33.4.3 Antiseize . Antiseize tape conforming to MIL-T-27730 or thread compound conforming to MIL-G-27617 shall be used on all male pipe thread fittings. The tape or compound shall not be used on flared tubefittings, straight threads, co
20、upling sleeves, or on the outside of the tube flares. None of the tape or compound shallbe allowed to enter the inside of a fitting. The tape shall be applied in accordance with instructions specified inMIL-T-27730. The compound shall be applied to the first three threads and the end of the fitting
21、wiped clean.3.4.4 Cleaning . All parts of the valve assemblies or flow controller, except the hose, shall be cleaned inaccordance with MIL-STD-1359.3.5 Performance .3.5.1 Valve Assemblies .3.5.1.1 Leakage . The valve assemblies shall show no indications of leakage when tested as specified (see4.6.l.
22、1).3.5.1.2 Retaining pin removal force . The force required to remove the retaining pin shall be 15 + 5 pounds asspecified (see 4.6.1.2).3.5.1.3 Fill and operation . When the valve assemblies are tested as specified (see 4.6.1.3), the force requiredto discharge the gas shall not be less than 10 nor
23、more than 20 pounds.3.5.1.4 Actuating cable housing retainer . The actuating cable housing retainer shall not become detachedfrom the valve when subjected to the test specified (see 4.6.1.4).3.5.1.5 Actuating, cable assembly . The actuating cable assembly shall withstand a pull of 30 pounds whentest
24、ed as specified (see 4.6.1.5).3.5.1.6 Operation at high and low temperature . The valve assemblies shall pass the high temperature(160 o F) and the low temperature (-65 o F) tests specified (see 4.6.1.6).3.5.1.7 Vibration . The valve assemblies shall pass the vibration test specified (see 4.6.1.7).
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILDTL7560D1997VALVEASSEMBLYOXYGENCYLINDERBAILOUT 紧急 跳伞 氧气瓶 阀门 组件 PDF

链接地址:http://www.mydoc123.com/p-427753.html