1、 MIL-DTL-25bbb/L 999990b 200b3b8 196 IINC“DI MI L-DTL-25666/ 1 (USAF) 15 September 1995 SUPERSEDING 15 January 197 1 MIL-C-25777C (USAF) DETAIL SPECIFICATION CONVERTER, LIQUID OXYGEN GCU-2A/A This specification is approved for use by the Department of the Air Force and is available for use by all De
2、partments and Agencies of the Department of Defense. I. SCOPE I. 1 Scope. This specification covers one type of liquid oxygen converter with a capacitance gauging element. It provides storage and pressurization of 10 liters of liquid oxygen to 70 pounds per square inch gauge (psig), nominal pressure
3、 and does not include warming coils. The converter is designated type GCU-2A/A 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are needed to meet the requirements specified in sections 3, 4, and 5 of this specification. This section does not include documents cited in other
4、 sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3,4, and 5 of this specification
5、, whether or not they are listed. 2.2 Government documents. 2.2.1 SDecifications. and standards. The following specifications and standards form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Depa
6、rtment of Defense Index for Specifications and Standards (DODISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS DEPARTMENT OF DEFENSE MIL-V-9050 MIL-C-255 16 MIL-DTL-25666 Valves, Oxygen, Pressure Relief, Aircraft Connectors, Electrical, Miniature, Coaxial, Environment
7、Resistant Type, Converter, Liquid Oxygen, Capacitance Type Gauging, General Specification General Specification For For Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: OC-ALC/TICLA, 300 1 Staff
8、Drive, Tinker AFB, OK 73 145- 3037 by using the self addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC NIA FSC 1660 DISTRIBU TION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for
9、ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-DTL-256bb/L m 9999906 2006369 O22 m c M IL-DTL-2566611 STANDARD DEPARTMENT OF DEFENSE MIL-STD- 129 (Unless otherwise indicated, copies of federal and military specifications, and standards are available from the Standard
10、ization Documents Order Desk, Building 4D, 700 Robbins Ave, Philadelphia, PA 19 I 1 1-5094) 2.3 Order of Precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this documents takes precedence. Nothing in this document, however, supersede
11、s applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Oualification. Converters furnished under this specification shall be products which are qualified for listing on the applicable qualified product list at the time set for opening of bids (see 4.2 an
12、d 6.3). 3.2 Desim. The converter shall conform to the dimensions and general design shown on figures i and 2. The converter shall have A minimum capacity of 10 liters of liquid oxygen measured at 1 atmosphere and shall be deigned for an operating pressure of 70 psig. 3.2.1 Schematic diagram. The con
13、verter shall be designed in accordance with the schematic diagram shown on figure 3. 3.2.2 Design strength. The filled converter shall be designed to withstand the following G forces without dam age : Vertical (down) 14G Vertical (up) 6G Lateral 6G 3.2.3 Relief valves. The relief valves shall confor
14、m to MIL-V-9050, type II. 3.2.4 Weight. The weight of the complete converter shall not exceed 20 pounds. 3.2.5 Marking of ports. Ports shall be marked as indicated on figure I. 3.3 Performance. 3.3. 1 Final assemblv messure. The converter shall meet the performance requirements for the final assembl
15、y pressure test of MIL-DTL-25666 when subjected to a final assembly pressure of 95 psig. 3.3.2 Filling - time. Filling time shall not exceed 5 minutes when the converter is tested as specified in MIL- DTL-25666. 3.3.3 Evaporation loss. 3.3.3.1 Vent condition. The evaporation loss of the essentially
16、full converter in the vent condition shall not exceed 3 pounds of oxygen when tested as specified in MIL-DTL-25666. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-DTL-25hhb/L q99990b 2006370 844 MIL-DTL-2566611 3.3.3.2 Buildup condition. The
17、evaporation loss of the essentially full converter in the buildup condition shall not exceed 3 pounds of oxygen when tested as specified in MIL-DTL-25666. 3.3.4 Buildup time. Buildup time shall not exceed 10 minutes when the converter is tested as specified in MIL- DTL-25666. 3.3.5 Capacitance. The
18、capacitance of the sensing element ofthe empty converter shall be 123.5 k1.0 picofarad (pf) when tested as specified in MIL-DTL-25666. 3.3.6 Inner vessel pressure. 3.3.6.1 Inner vessel. The inner vessel shall meet the performance requirements for the inner vessel pressure test specified in MIL-DTL-2
19、5666 when subjected to a pressure of 200 psig. 3.3.6.2 Permanent volumetric expansion. The converter shall meet the performance requirements for permanent volumetric expansion as specified in MIL-DTL-25666 when subjected to a pneumatic or hydrostatic pressure of 200 psig . 3 3.7 Deliverv rate. 3.3.7
20、.1 Constant flow. The converter shall deliver a flow of gaseous oxygen up to 72 liters per minute for not less than 1 .5 hours with the operating pressure remaining between 70 and 80 psig after the first 15 minutes of flow. Pressures in the supply line shall remain between 55 psig and 105 psig durin
21、g the entire period of flow. The flow at the specified rate shall be initiated within 10 minutes after the converter has reached the operating pressure. The full test procedure is specified in MIL-DTL-25666. 3.3.7.2 Cyclic flow. The converter shall deliver oxygen as specified (see 3.4.7.1) for not l
22、ess than 1.5 hours when tested as specified in MIL-DTL-25666. 3.3.8 Calibration. The capacitance sensing element shall have characteristics that provide for a linear relationship between electrical capacitance and volume of liquid oxygen sensed. The relationship shall be in accordance with figure 4,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILDTL2566611995CONVERTERLIQUIDOXYGENGCU2AAGCU2AA 液氧 转换器 PDF

链接地址:http://www.mydoc123.com/p-427704.html