1、 FSC 6130 A-A-59844A 28 December 2009 SUPERSEDING A-A-59844 05 November 2009 COMMERCIAL ITEM DESCRIPTION DIRECT CURRENT (DC) POWER SUPPLY The General Services Administration has authorized the use of the Commercial Item Description (CID) for all federal agencies. 1. SCOPE. This Commercial Item Descr
2、iption (CID), describes a 60 Watt, manual, single output DC power supply. This is a single output DC power supply power that includes a digital panel meter for monitoring voltage and current simultaneously. This CID is meant as a minimum requirement for a 60 Watt, single output, DC power supply in w
3、hich only those manufacturers that meet or surpass the following requirements are qualified per this CID. 2. SALIENT CHARACTERISTICS. The equipment shall be capable of operation within the accuracies, limits, and specifications herein. 2.1 Classification. Equipment covered by this CID shall be comme
4、rcially available equipment and may modified to the extent necessary to meet the following description. The equipment shall be Class 3, in accordance with MIL-PRF-28800. 2.2 Safety. The equipment shall be UL (Underwriters Laboratories) listed and approved and/or shall comply with the safety requirem
5、ents of MIL-PRF-28800 for the classification stated herein. 2.2.1. Leakage Current Protection. Protection shall be provided from leakage current in excess of 3.5 milli-amperes (mA) rms (AC and DC) from any accessible conductive parts of equipment (including control shafts with knobs broken or remove
6、d and recessed calibration or adjustment controls) to either pole of the power source for any position of the power switch(es). 2.3 Electrical Power Sources. The equipment shall operate from nominal single-phase commercial power source of 115Vac 10% at line frequencies of 50 Hz or 60 Hz. 2.3.1 Power
7、 Consumption. Maximum power consumption of all components combined shall not exceed 70 watts. 2.4 Dimensions and Weight. The equipment shall be no larger than: 4.0 inches high, 9.0 inches wide, and 16 inches deep. The weight including all accessories (excluding manual) shall not exceed 20 lbs. Benef
8、icial comments, recommendations, additions, deletions, clarifications, etc. and any other data that may improve this document should be sent to WR-ALC/742 CBSG/GBEC, 460 Richard Ray Bvld, Robins AFB, GA 31098-1813. Since contact information can change, you may want to verify the currency of this add
9、ress information using the ASSIST Online database at http:/assist.daps.dla.mil .INCH-POUNDProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59844A 22.5 Options. 2.5.1 Reusable Pouch Or Container. An attached accessory pouch may be used for storage
10、of all supplied accessories in lieu of front-cover storage. 2.6 Reliability. Reliability verification testing shall be in accordance with the requirements of MIL-PRF-28800 for the classification stated herein. 2.7 Calibration And Maintenance Adjustments. The design of the system shall provide for re
11、adily accessible calibration adjustments and maintenance adjustments. These adjustments shall be provided by variable value components, which are adjustable, by the use of simple means. The calibration by substitution of selected components or parts is unacceptable unless specifically approved. The
12、calibration adjustments, wherever possible, shall be accessible without removal of the instrument case or modules. 2.8 Performance Characteristics. The instrument shall meet all performance requirements specified herein. 2.8.1 Voltage. The voltage range shall be a minimum of 0-35 VDC in a dual or si
13、ngle range selectable from the front panel. 2.8.2 Operating Temperature Range. The equipment shall meet its performance and accuracy requirements in an operating environment of 0 C to 40 C. 2.8.3 Transient Response Time. The transient response time shall be less than 50 s following change in output
14、current from full load to half load for output to recover to within 15 mV. 2.8.4 Load Effect. The load effect on the power supply shall be no greater than 0.01% + 5mV for load variation from 0 to full load. 2.8.5 Line effect. The line effect on the power supply shall not be greater than 0.01% + 5 mV
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA59844A2009DIRECTCURRENTDCPOWERSUPPLY 直流 DC 电源 PDF

链接地址:http://www.mydoc123.com/p-427188.html