1、 FSC 6625 A-A-59755A 5 May 2010 SUPERSEDING A-A-59755 5 November 2004 COMMERCIAL ITEM DESCRIPTION WATTMETER, RADIO FREQUENCY The General Services Administration has authorized the use of this Commercial Item Description (CID) for all federal agencies. 1. SCOPE. This Commercial Item Description (CID)
2、, describes a Radio Frequency (RF) Wattmeter. This CID is meant as a minimum requirement for the RF Wattmeter in which only those manufacturers that meet or surpass the following requirements are to supply this wattmeter per this CID. The RF wattmeter described herein is a portable, insertion-type,
3、RF wattmeter used to measure continuous wave (CW) forward and reflected power in 50 ohm transmission lines using removable power elements. The RF Wattmeter described herein has a detachable load resistor accessory for terminated RF power measurements. 2. CLASSIFICATION. Equipment covered by this CID
4、 shall be commercially available equipment and may be modified to the extent necessary to meet this description. The equipment shall be Class 3 in accordance with MIL-PRF-28800, except as specified herein. 3. SALIENT CHARACTERISTICS. The equipment shall be capable of operation within the accuracies,
5、 limits, and specifications herein. 3.1 Safety and Environmental. The equipment shall meet all safety and environmental requirements as specified in MIL-PRF-28800 for the classification as stated herein. 3.1.1 Temperature Operating. The equipment shall conform to its specified performance and accura
6、cy while being operated in a temperature range of +10C to +45C. INCH-POUND Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any other data that may improve this document should be sent to 742 CBSG/LEEC, 460 Richard Ray Blvd, Suite 200, Robins AFB, GA 31098-1813. S
7、ince contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil/online/ . Provided by IHS Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59755A 2 3.1.2 Temperat
8、ure Non-operating. The equipment shall conform to its specified performance and accuracy after being stored in an environment in the temperature range of -10C to +45C. 3.2 Electrical Power Sources. The equipment shall operate from nominal single-phase commercial, military, and shipboard power source
9、s of 120 volts AC (10%) or 240 volts AC (10%) at line frequencies of 47.5 Hz to 52.5 Hz and 57 Hz to 63 Hz. Transient state conditions shall meet MIL-PRF-28800 requirements for the classification specified herein. The equipment shall also have internal rechargeable battery power. The battery/batteri
10、es shall provide power for the unit for a minimum of 8 hours with average use before recharging is necessary. The batteries shall be capable of being recharged to full potential in less than 16 hours. 3.3 Reliability. The design of the equipment shall be such that under normal use and operation the
11、equipment does not fail within 1500 hours of operation with a statistical certainty of 95%. 3.4 Calibration and Maintenance Adjustments. The design of the system shall provide for readily accessible calibration adjustments and maintenance adjustments. The calibration adjustments, wherever possible,
12、shall be accessible without removal of the equipment case or modules. The calibration interval shall be a period of one year or greater based on an operating time of 2000 hours. No special tools shall be required for alignment or adjustment except those furnished with the equipment. 3.5 Performance
13、Requirements. The equipment shall meet all requirements specified herein, after the warm-up period specified in MIL-PRF-28800, under all combinations of input power conditions, output signal conditions and operating service condition as specified in MIL-PRF-28800. 3.5.1 Frequency. The wattmeter freq
14、uency range shall include 450 kHz to 2.3 GHz. 3.5.2 Power. The power range of the wattmeter shall be a minimum of 100 milliwatts to 2.0 kilowatts as a directional wattmeter and 0 to 100 watts with a detachable load resistor. 3.5.2.1 Power Accuracy. The accuracy of the wattmeter shall be within 7% of
15、 full scale for continuous wave (CW) power measurements and within 8% of full scale for peak envelope power (PEP) power measurement. 3.5.3 Power Elements. The directional wattmeter shall be compatible with standard forward and reflected power Plug-in Elements which correspond to the frequency and po
16、wer levels to be measured. However, the wattmeter shall not be supplied with the power elements. 3.5.4 Modulation Frequency. The minimum modulation frequency range for the wattmeter shall be 30 Hz to 10 kHz. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IH
17、S-,-,-A-A-59755A 3 3.5.4.1 Percent Modulation. The wattmeter shall measure percent modulation, for power levels greater than one third of full scale, with an accuracy of 5 % for 0 to 90 % modulation and 10 % accuracy for 90 to 100 % modulation. 3.5.5 Standing Wave Ratio (SWR). The wattmeter shall me
18、asure SWR for the range 1.00 to 85.00 to an accuracy of 10 % (worst case) of the reading. 3.5.6 Return Loss. The wattmeter shall measure the return loss of signals for the range 0 to 30.0 dB with an accuracy of 0.3 dB to corresponding SWR. 3.5.7 Interface. 3.5.7.1 Wattmeter Control. The controls tha
19、t operate the wattmeter shall be on the front or face panel. 3.5.7.2 Connectors. The wattmeter shall have type N female connectors. 3.5.7.2.1 Impedance. The wattmeter shall have an impedance of 50 ohms. 3.5.7.3 Insertion VSWR. The maximum insertion VSWR of the wattmeter shall be less than or equal t
20、o 1.05:1 for frequencies less than 1.0 GHz. 3.5.7.4 Display. The wattmeter shall have a minimum of three (3) character display with floating decimal point. The wattmeter shall be able to display the following operation modes and indicators: Forward power; Reflected power; SWR or VSWR; Return Loss; P
21、ercent Modulation; Watts and dBm (dB); Over-range Indicator; and Low Battery. 3.5.7.5 External Interface. The equipment shall be compatible with optional IEEE-488 or EIA/TIA-232-F capability. 3.5.7.6 Pulse Parameters. The equipment shall make measurements with the following minimum square pulse modu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA59755A2010WATTMETERRADIOFREQUENCY 射频 瓦特计 PDF

链接地址:http://www.mydoc123.com/p-427161.html